• 제목/요약/키워드: Power-saving efficiency

검색결과 354건 처리시간 0.026초

인버터 구동 원심펌프의 급수 사용율에 따른 에너지 절감 평가 (Evaluation of Energy Savings for Inverter Driving Centrifugal Pump with Duty Cycles)

  • 김경욱;서상호;라키부자만
    • 한국유체기계학회 논문집
    • /
    • 제18권6호
    • /
    • pp.81-85
    • /
    • 2015
  • The purpose of this study is to evaluate energy savings for inverter driving multi-stage centrifugal pump. Variable speed driving pump system has high efficiency compared with constant speed driving pump system. Because of difficulty to estimate operating efficiency of variable speed driving pump system, energy saving rates are used to replace operating efficiency. energy saving rates are calculated from pump input power and pump duty cycle. But another researches have used pump duty cycles of each season for energy saving rate. In this study, for estimating energy saving rate more high accuracy, pump duty cycles are measured for 1 year. pump duty cycles, depending on the season and be classified according to the weekday/weekend or during the week day. By this pump duty cycles, Energy saving rate is calculated appropriately.

CFD를 이용한 KRISO 추진효율 향상 장치(K-duct)의 성능 해석 (CFD Analysis of Performance of KRISO Devices (K-DUCT) for Propulsion Efficiency Improvement)

  • 서성부
    • 한국해양공학회지
    • /
    • 제31권3호
    • /
    • pp.183-188
    • /
    • 2017
  • This paper provides numerical results for the estimation of the efficiency of KRISO energy saving devices in the design stage. A finite volume method is used to solve Reynolds averaged Navier-Stokes (RANS) equations, where the SST k-$\omega$ model is selected for turbulence closure. The propeller rotating motion is determined using a rigid body motion (RBM) scheme, which is called a sliding mesh technique. The numerical analysis focuses on predicting the power reduction by the designed KRISO devices (K-DUCT) under a self-propulsion condition. The present numerical results show good agreement with the available experimental data. Finally, it is concluded that CFD can be a useful method, along with model tests, for assessing the performance of energy saving devices for propulsion efficiency improvement.

Utility AC Frequency to High Frequency ACPower Conversion Circuit with Soft Switching PWM Strategy

  • Sugimura Hisayuki;Ahmed Nabil A.;Ahmed Tarek;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권2호
    • /
    • pp.181-188
    • /
    • 2005
  • In this paper, a DC smoothing filterless soft switching pulse modulated high frequency AC power conversion circuit connected to utility. frequency AC power source is proposed for consumer induction heating hot water producer, steamer and super heated steamer. The operating principle of DC link filterless utility frequency AC-high frequency AC (HF AC) power conversion circuit defined as high frequency cycloinverter is described, which can operate under a principle of ZVS/AVT and power regulation based on alternate asymmetrical PWM in synchronization with the utility frequency single phase AC positive or negative half wave voltage. The dual mode modulation control scheme based on high frequency PWM and commercial frequency AC voltage PDM for the proposed high frequency cycloinverter are discussed to enlarge its soft switching commutation operating range for wide HF AC power regulation. This high frequency cycloinverter is developed for high frequency IH Dual Packs Heater (DPH) type boiler used in consumer and industrial fluid pipeline systems. Based on the experiment and simulation results, this high frequency cycloinverter is proved to be suitable for the consumer use IH-DPH boiler and hot water producers. The cycloinverter power regulation and power conversion efficiency characteristics are evaluated and discussed.

Design of Low-Power TFT-LCD Source Driver

  • Sung, Yoo-Chang;Choi, Byong-Deok;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.17-18
    • /
    • 2000
  • A low-power source driver for TFT-LCDs has been proposed using the triple charge sharing method that enhances the AC power saving efficiency of the prior charge sharing method. The AC power saving efficiency of the proposed source driver reaches 66.6%. In addition, a novel OP-AMP with low-quiescent current has been developed. The measured quiescent current of the OP-AMP is $5{\mu}A{\sim}7{\mu}A$ at VDD=5V and VSS=0V with load resistance of $2k{\Omega}$ and load capacitance of 300pF.

  • PDF

Induction Heated Load Resonant Tank High Frequency Inverter with Asymmetrical Auxiliary Active Edge-Resonant Soft-Switching Scheme

  • Saha Bishwajit;Fathy Khairy;Kwon Soon-Kurl;Lee Hyun-Woo;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.200-202
    • /
    • 2006
  • In this paper, a novel type of auxiliary active snubbing circuit assisted quasi-resonant soft-switching pulse width modulation inverter is proposed for consumer induction heating equipments. The operation principle of this high frequency inverter is described using switching modes and equivalent circuits. This newly developed series resonant high frequency inverter can regulate its high frequency output AC power under a principle of constant frequency active edge resonant soft-switching commutation by asymmetrical PWM control system. The high frequency power regulation and actual power conversion efficiency characteristics of consumer induction heating (IH) products using the proposed soft-switching pulse width modulation (PWM) series load resonant high frequency inverter evaluated. The practical effectiveness and operating performance of high frequency inverter are discussion on the basis of simulation and experimental results as compared with the conventional soft-switching high frequency inverter.

  • PDF

국내 주요 가전제품의 대기전력저감기술 성과 분석 : 에너지절약 효과를 중심으로 (Analysis Result for the Technical Development Reducing Standby Power in Domestic Major Electric Appliances : The Electricity Energy Saving Effect)

  • 이은영;정순희
    • 가정과삶의질연구
    • /
    • 제27권4호
    • /
    • pp.141-160
    • /
    • 2009
  • Recently, some policies for reducing standby power, which has quite an effect on electricity consumption, have been employed all over the world. This study surveys the present condition of standby power for major electric home appliances during three years and analyzes the result of technical development reducing standby power. It presents how the industry paid attention to applying the technique of reducing standby power to electric appliances and how it affects the product's energy efficiency. We survey the standby power's change for six items, which were selected from the major electric appliances available on the market. It analyzes the difference of standby power consumption between appliances with a standby power reducing technique and those without during the latest three years. The amount of the average standby power is also compared. The comparison data confirms that the industry's effort and application of reducing standby power contribution has contributed to increasing an appliance's energy efficiency. This study restricted the analyzed items to six appliances, which has been a low volunteered involvement in the standby power reducing program. It is important for reducing standby power consumption of appliances because it contributes to saving electric energy at home and abroad. The development of the standby power reducing technique is needed for more appliances. Along with the development of the standby power reducing technique in the industrial field, it also necessary for consumers to enlarge their understanding of standby power reduction for economic, social, and environmental values.

절전형 제빙시설 사이클 모사를 통한 성능 및 경제성 해석 (Analysis of Performance and Economical Efficiency through Cycle Simulation for Power Saving BIP(Block Ice Plant))

  • 강종호;김남진;이재용;김종보
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.455-461
    • /
    • 2001
  • Domestic ice making companies make effort to obtain products and neglect to introduce low cost product improvements with energy savings. The work presented here is an implementation of ice making method to improve both energy efficiency and productivity. In this present investigation, several ice making cycles are proposed for higher efficiency in the system. COP(Coefficient of Performance), ice making time and electric energy consumption are evaluated and compared with the conventional system. Results shows that COP is improved with more efficient use of time for ice making and electric consumption. Therefore, this can offer an opportunity for more efficient use of energy and higher productivity in ice making.

  • PDF

가변 위상각제어에 의한 에너지절감형 단상유도전동기에 관한 연구 (A Study on the Energy Saving SPIM Using Variable Phase Angle Control)

  • 박수강;백형래;이상일;임양수;최낙일
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.522-525
    • /
    • 1999
  • This paper describes a simple but effective method for energy saving of ac motors having a widely variable load. The proposed method is based on an optimal efficiency control which is operated by voltage-current pattern such as to maintain the maximum efficiency on the efficiency-output characteristics of the motor, in voltage control with triac. In this paper, authors present the experimental results of the SPIM under controlling of current of main and auxiliary winding by using a one chip microcontroller. Experiments are focused on a capacitor stating single phase induction motor the optimal energy saving are proved by the proposed method.

  • PDF

초임계압형 화력발전소의 성능시험을 통한 최고효율점 선정에 관한 연구 (A Study on the Selection of Maxium Plant Efficiency through the Performance Test in Snper-Critical Power Plant)

  • 권여수;서정세
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.402-407
    • /
    • 2003
  • The main reason to select the maxium plant efficiency through the performance test in fossil power plant is to increase the efficiency of power plant as well as saving energy collated with the policy of government. This study is aimed at unerstanding the variantion trend of efficiency and analyzing the efficiency of boiler and turbine through each of the performance test. Ultimately, the maxium efficiency of power plant will be presented in super-critical pressure type power plant.

  • PDF

스마트플러그(IOT)를 이용한 대학시설의 전기에너지 사용량 계측 및 분석 사례 연구 (A Case Study of Measuring and Analyzing Electric Energy Usage in University Facilities Using Smart Plug)

  • 박준영;이춘경;박태근
    • 대한건축학회논문집:구조계
    • /
    • 제34권9호
    • /
    • pp.27-34
    • /
    • 2018
  • The purpose of this study is to demonstrate and analyze the function of a Smart Plug before and after it is applied on the electrical appliances by controlling standby power usage. The research measures and analyzes the amount of electrical energy used while activating the Smart Plug with two types of appliances in a university facilities. The smart plugs were applied into a Group 1 appliances (Multi-function device, computer, laptop, Air con) which completely hinder the standby power, and a Group 2 appliances (Refrigerator, cold and hot water dispenser) which does not completely hinder the standby powers due to the characteristics of the function. First, the total standby power saving of all electrical appliances (Group 1 and Group 2) using the Smart plug was measured as 4.59%. Second, the energy saving of the Group 1 products was analyzed as 26.43%. Third, the standby power saving of the air conditioners from mid October to early December was measured as 31.06%, during the seasons when air conditioning was not actively in use. The research indicates that all specified appliances did have better energy efficiency with the Smart plug regardless of the amount of energy usage.