• Title/Summary/Keyword: Power-feeding

Search Result 413, Processing Time 0.03 seconds

Analysis on Voltage and Cost of Substation with PWM Rectifier in DC Traction Power Supply System (PWM 정류기를 적용한 직류급전시스템의 전압강하 및 비용 평가)

  • Kim, Joorak;Park, Kijun;Park, Chang-Reung;Choo, Eun-Sang;Lee, Jun-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.4
    • /
    • pp.640-645
    • /
    • 2015
  • Near surface transit system has should be constructed as installation cost of light rail transit with elevated track. So, distance between two substations is longer than conventional system. The long feeding distance results in severe voltage drop. This paper proposes a PWM rectifier instead of diode rectifier. The PWM rectifier has some advantages. This is able to control output voltage constantly to reduce voltage drop and to use regeneration power without additional inverter. This paper analyse on improved voltage profile and cost of substation with PWM rectifier. The analysis of voltage profile use PSIM, and the installation cost of substation with PWM rectifier is compared to substation with diode rectifier.

Realization of Optimum Loads for Maximum WPT Efficiencies Using Multi-Turn Receiving Coil (수신 코일 권선 수 변화에 의한 무선전력전송 최적 부하 구현)

  • Hwang, Sungyoun;Lee, Bomson
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.4
    • /
    • pp.335-341
    • /
    • 2016
  • In this paper, we propose the method of controling the turns of a receiving coil for the matching directly to the receiver input impedance(typically $50{\Omega}$) with a maximum wireless power transfer(WPT) efficiency. Based on the presented the expression of the optimum load depending on a system figure of merit, number of the turns of a receiving coil, and proximity effect between conducting lines, the theoretical efficiencies have been compared with the measured ones with a good agreement. The results of this work may be used to realize a allowable maximum efficiency with a simple and low-profile 2-coil WPT system not requiring a separate feeding loop.

Estimation of the Economic Coal Feeding Temperature at the Time of Fuel Change to Russian Bituminous Coal during Starting up for CFB Power Plant (발전용 유동층보일러 기동 기간 중 러시아산 유연탄으로의 연료 교체시 경제적인 투입온도 예측)

  • Song, Ha-Kyoung;Kim, Jin-Kuk
    • Plant Journal
    • /
    • v.11 no.3
    • /
    • pp.46-52
    • /
    • 2015
  • 200MWe 순환유동층보일러인 A화력발전소는 정부정책에 의해 국내 무연탄만을 연료로 배정받아 운영되었다. 하지만 무연탄에 대한 민간수요 증가에 따른 정부의 정책변경에 따라 유 무연탄 혼탄을 2000년대 후반부터 시행하고 있다. 하지만 기동시 석탄 투입온도는 여전히 무연탄 전소시의 기준온도인 $600^{\circ}C$에 석탄을 투입하고 있는 실정이라 기동시간 지연의 한 원인으로 작용하고 있고 기동 중 소요되는 경유의 과다소비라는 고질적인 문제점을 안고 있다. 이에 본 연구에서는 A화력에서 사용되는 석탄에 대한 공업분석과 원소분석을 통하여 비교적 휘발분이 많고 반응성이 좋은 러시아산 유연탄(Suek) 연소에 따른 경유에서 석탄으로의 연료교체시 경제적인 시점을 예측하였다. 실험결과 러시아산 유연탄 (Suek) 연소시 투입가능온도는 연소전환율이 90%이상이 되는 연소최대온도($426^{\circ}C$)가 기술적, 경제적으로 가장 적합한 것으로 예상하였다.

  • PDF

New Backstepping-DSOGI hybrid control applied to a Smart-Grid Photovoltaic System

  • Nebili, Salim;Benabdallah, Ibrahim;Adnene, Cherif
    • International Journal of Computer Science & Network Security
    • /
    • v.22 no.4
    • /
    • pp.1-12
    • /
    • 2022
  • In order to overcome the power fluctuation issues in photovoltaic (PV) smart grid-connected systems and the inverter nonlinearity model problem, an adaptive backstepping command-filter and a double second order generalized Integrators (DSOGI) controller are designed in order to tune the AC current and the DC-link voltage from the DC side. Firstly, we propose to present the filter mathematical model throughout the PV system, at that juncture the backstepping control law is applied in order to control it, Moreover the command filter is bounded to the controller aiming to exclude the backstepping controller differential increase. Additionally, The adaptive law uses Lyapunov stability criterion. Its task is to estimate the uncertain parameters in the smart grid-connected inverter. A DSOGI is added to stabilize the grid currents and eliminate undesirable harmonics meanwhile feeding maximum power generated from PV to the point of common coupling (PCC). Then, guaranteeing a dynamic effective response even under very unbalanced loads and/or intermittent climate changes. Finally, the simulation results will be established using MATLAB/SIMULINK proving that the presented approach can control surely the smart grid-connected system.

Modeling for the Analysis of Rail Potential in the DC Railway Power System (직류전기철도 급전시스템에서 레일전위 해석을 위한 모델링)

  • Cho, Woong-Ki;Choi, Kyu-Hyoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.138-146
    • /
    • 2010
  • DC railway power supply system generally uses the running rails as negative-polarity return conductor for traction load current, and the induced rail potential and stay current cause serious problems to any electrified matter in the underground and also safety problems to human body. This paper presents a new algorithm for the analysis of the rail potential and the stray current in DC railway power system operated under independent/parallel power feeding mode. The effect of load current fluctuation during train operation is also calculated by using TPS(Train Performance Simulation) program to analysis the variation of the railway potential and stray current along railway track. Simulation program is developed based on the proposed algorithm and case studies are provided.

Verification of SPACE Code with MSGTR-PAFS Accident Experiment (증기발생기 전열관 다중파단-피동보조급수냉각계통 사고 실험 기반 안전해석코드 SPACE 검증)

  • Nam, Kyung Ho;Kim, Tae Woo
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.84-91
    • /
    • 2020
  • The Korean nuclear industry developed the SPACE (Safety and Performance Analysis Code for nuclear power plants) code and this code adpots two-phase flows, two-fluid, three-field models which are comprised of gas, continuous liquid and droplet fields and has a capability to simulate three-dimensional model. According to the revised law by the Nuclear Safety and Security Commission (NSSC) in Korea, the multiple failure accidents that must be considered for accident management plan of nuclear power plant was determined based on the lessons learned from the Fukushima accident. Generally, to improve the reliability of the calculation results of a safety analysis code, verification work for separate and integral effect experiments is required. In this reason, the goal of this work is to verify calculation capability of SPACE code for multiple failure accident. For this purpose, it was selected the experiment which was conducted to simulate a Multiple Steam Generator Tube Rupture(MSGTR) accident with Passive Auxiliary Feedwater System(PAFS) operation by Korea Atomic Energy Research Institute (KAERI) and focused that the comparison between the experiment results and code calculation results to verify the performance of the SPACE code. The MSGR accident has a unique feature of the penetration of the barrier between the Reactor Coolant System (RCS) and the secondary system resulting from multiple failure of steam generator U-tubes. The PAFS is one of the advanced safety features with passive cooling system to replace a conventional active auxiliary feedwater system. This system is passively capable of condensing steam generated in steam generator and feeding the condensed water to the steam generator by gravity. As the results of overall system transient response using SPACE code showed similar trends with the experimental results such as the system pressure, mass flow rate, and collapsed water level in component. In conclusion, it could be concluded that the SPACE code has sufficient capability to simulate a MSGTR accident.

Population Structure of Surface Swarms of the Euphausiid Euphausia pacifica Caught by Drum Screens of Uljin Nuclear Power Plant in the East Coast of Korea

  • Suh, Hae-Lip;Lim, Ju-Hwan;Soh, Ho-Young
    • Journal of the korean society of oceanography
    • /
    • v.33 no.1-2
    • /
    • pp.35-40
    • /
    • 1998
  • In February and April 1997, three temporary interruptions of electric power production at the Uljin Nuclear Power Plant in the east coast of Korea were caused by the malfunction of the cool-ing-water supply unit. The clogging of the drum screens inside the unit caused by the surface swarm of the euphausiid Euphausia pacifica Hansen might be responsible for the malfunction. These incidents were of particular interest since such interruption of reactors' operation by krill swarms had not previously been reported. Using samples caught by the drum screens inside the cooling water-supply unit, we investigated the population structure of surface swarms. One occasion of nighttime and three occasions of daytime surface swarms were found in February and April 1997, respectively. The foreguts of more than 60% of E. pacifica in nighttime surface swarm were in full condition. This evidence suggests that E. pacifica aggregates to the surface water at night for feeding. In daytime surface swarms consisting of mature E. pacifica, however, foreguts in full condition were only found in less than 10eio of krill examined, suggesting that daytime surface swarms are closely related to breeding activity. During the study period, the growth rate of mature females was more than twice higher than that of mature males. Analyses of the sex-ratio and length-frequency data show a decrease in the portion of males with increasing size. There was a decline in the number of males of 19 mm in length. Energy loss during spermatophore transfer may result in the death of male E. pacifica, as found in male E. superba.

  • PDF

Study on the Railway Fault Locator Impedance Prediction Method using Field Synchronized Power Measured Data (실측 동기화 데이터를 활용한 교류전기철도의 고장점표정장치 임피던스 예측기법 연구)

  • Jeon, Yong-Joo;Kim, Jae-chul
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.5
    • /
    • pp.595-601
    • /
    • 2017
  • Due to the electrification of railways, fault at the traction line is increasing year by year. So importance of the fault locator is growing higher. Nevertheless at the field traction line, it is difficult to locate accurate fault point due to various conditions. In this paper railway feeding system current loop equation was simplified and generalized though measured data. And substation, train power data were measured under synchronized condition. Finally catenary impedance was predicted through generalized equation. Also simulation model was designed to figure out the effect of load current for train at same location. Train current was changed from min to max range and catenary impedance was compared at same location. Finally, power measurement was performed in the field at train and substation simultaneously and catenary system impedance was predicted and calculated. Through this method catenary impedance can be measured more easily and continuously compared to the past method.

Study on Analysis of Operating Characteristics of Motor Block While KTX is Moving at Neutral Section of Kyung-Bu High Speed Line (경부고속선 절연구간에서 KTX 운행중 모터블럭의 동작특성 분석)

  • Choi, Chang Hyun;Lho, Young Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1523-1527
    • /
    • 2015
  • Traction power is supplied by three-phase alternating current of 154 kV power grid and electric trains are operated on single phase feeding system. It becomes important to use all the three phases equally and convert them into two-phase electric power (90 degree phase rotation) for traction supply. This is achieved by special transformer from the adjacent traction substation which is separated by a neutral section. Neutral section locations are in front of the substation and between the two substations. The first stage of the Seoul-Busan high-speed railway, design curve radius is larger than 7,000 m and the greatest slope is 25‰. The railway track conditions are evaluated as good enough to install a neutral section at the first stage, but a few factors of coasting operation of the train should be considered at the second stage of Seoul-Busan high-speed railway. The neutral section was located at Kim-cheon substation, which made some neutral section problems produced by the operating train, and the neutral section was moved about 1.5 km to the south toward Dong Dae-gu station due to the track operation condition. Some of the trains which stopped at the existing Kim-cheon Gu-mi station produced another motor block failure after moving the neutral section. In this paper, power quality, system performance and track condition, etc. are suggested to solve the problems.

Design of a Circular Polarization Microstrip Patch Antenna for ISM Band Using a T-junction Power Divide (T-junction 전력 분배기를 이용한 ISM 대역의 원형 편파 마이크로스트립 패치 안테나 설계)

  • Kim, Sun-Woong;Kim, Ji-Hye;Kim, Su-Jeong;Park, Si-Hyeon;Choi, Dong-You
    • The Journal of Korean Institute of Information Technology
    • /
    • v.16 no.11
    • /
    • pp.77-84
    • /
    • 2018
  • In this paper, the circular polarization microstrip patch antenna using the T-junction power divider is proposed. The operating frequency of the proposed antenna is ISM band of 2.4GHz and the circular polarization is induced by feeding a phase difference of $90^{\circ}$ in two edges. The structure of the antenna consists of a general patch and a T-junction power divider. Furthermore, to optimize the proposed antenna, it is analyzed the reflection coefficient, the axial ration and the radiation pattern. The impedance bandwidth of the antenna is observed to be 40MHz within a range of 2.39 to 2.43GHz, similarly, the axial ratio bandwidth is observed having the bandwidth of about 12MHz in 2.398 to 2.410GHz range. The radiation pattern of the antenna is seen to be right circular polarization. Furthermore, the gain of the antenna is observed to be 2.04 and 3.4dBic at XZ and YZ-plane, respectively.