• Title/Summary/Keyword: Power-Operated-Valve

Search Result 105, Processing Time 0.026 seconds

Fabrication and Performance of Electron Cyclotron Resonance Ion Milling System for Etching of Magnetic Film Device (자성박막 소자 에칭용 전자 사이클로트론 공명 이온밀링 시스템 제작과 특성연구)

  • Lee, Won-Hyung;Hwang, Do-Guwn;Lee, Sang-Suk;Rhee, Jang-Roh
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.5
    • /
    • pp.149-155
    • /
    • 2015
  • The ECR (Electron Cyclotron Resonance) Ar ion milling was manufactured to fabricate the device of thin film. The ECR ion milling system applied to the device etching operated by a power of 600W, a frequency of 2.45 GHz, and a wavelength of 12.24 cm and transferred by a designed waveguide. In order to match one resonant frequency, a magnetic field of 908 G was applied to a cavity inside of ECR. The Ar gas intruded into a cavity and created the discharged ion beam. The surface of target material was etched by the ion beam having an acceleration voltage of 1000 V. The formed devices with a width of $1{\mu}m{\sim}9{\mu}m$ on the GMR-SV (Giant magnetoresistance-spin valve) multilayer after three major processes such as photo lithography, ion milling, and electrode fabrication were observed by the optical microscope.

Experimental Study on the Cooling and Heating Characteristics of System A/C Applying the Digital Scroll Compressor (디지털 스크롤 압축기를 적용한 시스템 에어컨의 냉난방특성에 대한 실험적 연구)

  • Jeon, Yong-Ho;Kim, Dae-Hoon;Kwon, Young-Chul;Jang, Geun-Sun;Lee, Yoon-Soo;Moon, Je-Nyung;Yoon, Baek;Hong, Ju-Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.454-460
    • /
    • 2003
  • In order to investigate the cooling and heating characteristics of a variable-capacity system A/C applying a digital scroll compressor, the cooling and heating capacities and COP are measured by the psychrometric calorimeter. The capacity of the system is controlled by the digital scroll compressor, which is operated by controling PWM valve and the loading vs. unloading time. In the case of unloading compared that of loading, the consumption power of the compressor is about 11% and the capacity variation of the system A/C is within about 1%. When the system A/C is operated under the cooling and heating standard conditions, COP is nearly uniform but cooling capacity and heating capacity increase at minimum, rated and maximum modes. The system A/C applying the digital scroll compressor is effective for the range with high load or the width of large load variation. When the auxiliary heater is on, at the cold region, the system A/C produces the excellent heating capacity.

Electro-pneumatic regulator using multilayer PZT actuator (적층형 압전액추에이터 방식 전-공 레귤레이터)

  • Yun, So-Nam;Kim, Chan-Yong;Park, Jung-Ho;Youn, Dong-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.979-984
    • /
    • 2007
  • This paper presents a new control mechanism for the proportional pressure control which is accomplished by electro-pneumatic regulator using two PZT actuators. The electro-pneumatic regulator of this study is 2-stage type and consists of two piezoelectric actuators, a controller and a main poppet valve. The piezoelectric actuators are multilayer bender type and are controlled by digital signal. Proportional pressure control technique is very important because that can derive improvement of product quality and driving ability in the pneumatic system. Solenoid actuator method for pressure control is widely used but this actuator has a high power consumption characteristics. So new actuator is required for the energy saving. In this study, PZT actuator for the pressure control was fabricated and experimented instead of the conventional type solenoid actuator. Experiments for the new control mechanism of the elector-pneumatic regulator were operated under the input condition of 0.4[MPa] and it was confirmed that this mechanism has a good control characteristics to the response sensitivity and hysteresis.

  • PDF

DEVELOPMENT OF AN OPERATION STRATEGY FOR A HYBRID SAFETY INJECTION TANK WITH AN ACTIVE SYSTEM

  • JEON, IN SEOP;KANG, HYUN GOOK
    • Nuclear Engineering and Technology
    • /
    • v.47 no.4
    • /
    • pp.443-453
    • /
    • 2015
  • A hybrid safety injection tank (H-SIT) can enhance the capability of an advanced power reactor plus (APR+) during a station black out (SBO) that is accompanied by a severe accident. It may a useful alternative to an electric motor. The operations strategy of the H-SIT has to be investigated to achieve maximum utilization of its function. In this study, the master logic diagram (i.e., an analysis for identifying the differences between an H-SIT and a safety injection pump) and an accident case classification were used to determine the parameters of the H-SIT operation. The conditions that require the use of an H-SIT were determined using a decision-making process. The proper timing for using an H-SIT was also analyzed by using the Multi-dimensional Analysis of Reactor Safety (MARS) 1.3 code (Korea Atomic Energy Research Institute, Daejeon, South Korea). The operation strategy analysis indicates that a H-SIT can mitigate five types of failure: (1) failure of the safety injection pump, (2) failure of the passive auxiliary feedwater system, (3) failure of the depressurization system, (4) failure of the shutdown cooling pump (SCP), and (5) failure of the recirculation system. The results of the MARS code demonstrate that the time allowed for recovery can be extended when using an H-SIT, compared with the same situation in which an H-SIT is not used. Based on the results, the use of an H-SIT is recommended, especially after the pilot-operated safety relief valve (POSRV) is opened.

An Experimental Investigation of Thermodynamic Performance of R-22 Alternative Blends

  • Kim, Chang-Nyeon;Park, Young-Moo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.36-44
    • /
    • 1998
  • R-410a and R-407c which have the best potential among R-22 alternatives were tested as drop-in refrigerants against a set of R-22 baseline tests. The performance evaluations were carried out in a psychometric calorimeter test facility using the residential spilt type air conditioner under the ARI rating conditions. Except the lubricant and hand-operated expansion valve, the other parts of the air conditioner were the same with the commercial system. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly charged into the current refrigeration system because its vapor pressure and other thermochemical properties are similar to those of R-22. However, it is required to change the volume flow rate of compressor in order to achieve the volumetric capacity of R-22. This results from its relatively small VCR and capacity. Meanwhile, R-410a has vapor pressure values too high to be substituted for the current system and this resulted relatively low COP of R-410a compared to that of R-22.

  • PDF

An experimental investigation of thermodynamic performance of R-22 alternative blends (R-22 대체용 혼합냉매의 열역학적 성능에 대한 실험연구)

  • Hwang, E.P.;Kim, C.N.;Park, Y.M.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.1
    • /
    • pp.82-91
    • /
    • 1997
  • R-410a and R-407c witch have the best potential among the substances being considered as R-22 alternatives were tested as "drop in" refrigerants against a set R-22 baseline tests for comparison. The performance evaluations were carried out in a psychrometric calorimeter test facility using the residential split-type air conditioner under the ARI rating conditions. Other than the use of different lubricant and a hand-operated expansion valve, one of the commercial systems was selected for the experiment. Performance characteristics were measured; compressor power, capacity, VCR, mass flow rate and COP. The tests showed that R-407c can be directly applied to the existing refrigeration system because of its similar vapor pressure and other thermopysical properties with those of R-22. However, it required change to the volume flow rate of compressor in order to achieve the similar performance with R-22 because of its relatively small VCR and capacity. Meanwhile, R-410a has too high a vapor pressure to be applied to the existing system and this feature results in relatively low COP of the system compared to that of R-22. But this could be improved by changing compressor design considering R-410a's relatively high VCR and capacity compared to those of R-22.

  • PDF

Performance Evaluation of R-22 Alternative Refrigerants with Hydrofluorocarbon and Hydrocarbon (HFC 및 탄화수소를 포함한 R-22 대체냉매의 성능평가)

  • 김창년;박영무;이병권;임종성
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.315-324
    • /
    • 2000
  • R-410A, R-407C, and four refrigerant mixtures composed of R-32, R-l34a, R-l43a, R-l52a, R-600(butane), and R-600a(isobutane) were tested in an attempt to replace R-22 used in most of the residential air conditioners. The performance evaluation was carried out in a psychrometric calorimeter test facility using a residential spilt type air conditioner under the KS rating conditions. Except for the lubricant and hand-operated expansion valve, the other parts of the air conditioner were the same with the commercial system. Performance characteristics were measured; COP, capacity, compressor power, and VCR. R-410A was shown to have 5.5% higher COP and 3.5% lower capacity than R-22. R-32/134a/600a (42.8/ 46.0/11.2 wt%) mixture have the best performance among the four refrigerant mixtures composed of hydrofluorocarbon and hydrocarbon. This inixture have 3.0% lower COP and 1.6% lower capacity than R-22.

  • PDF

Analysis of fission product reduction strategy in SGTR accident using CFVS

  • Shin, Hoyoung;Kim, Seungwoo;Park, Yerim;Jin, Youngho;Kim, Dong Ha;Jae, Moosung
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.812-824
    • /
    • 2021
  • In order to reduce risks from the Steam Generator Tube Rupture (SGTR) accident and to meet safety targets, various measures have been analyzed to minimize the amount of fission product (FP) release. In this paper, we propose an introduction of a Containment Filtered Venting System (CFVS) connected to the steam generator secondary side, which can reduce the amount of FP release while minimizing adverse effects identified in the previous studies. In order to compare the effect of new equipment with the existing strategy, accident simulations using MELCOR were performed. As a result of simulations, it is confirmed that CFVS operation lowers FP release into the environment, and the release fractions are lower (minimum 0.6% of the initial inventory for Cs) than that of the strategy which intends to depressurize the primary system directly (minimum 15.2% for Cs). The sensitivity analyses identify that refill of the CFVS vessel is a dominant contributor reducing the amount of FP released. As the new strategy has the possibility of hydrogen combustion and detonation in CFVS, the installation of an igniter inside the CFVS vessel may be considered in reducing such hydrogen risk.

Real operation of 2 kW class reverse-Brayton refrigeration system with using scroll compressor package

  • Kim, Hyobong;Yeom, Hankil;Choo, Sangyoon;Kim, Jongwoo;Park, Jiho;In, Sehwan;Hong, Yong-Ju;Park, Seong-Je;Ko, Junseok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.40-44
    • /
    • 2020
  • This paper describes the real operation of 2 kW class reverse-Brayton refrigeration system with neon as a working fluid. The refrigeration cycle is designed with operating pressure of 0.5 and 1.0 MPa at low and high pressure side, respectively. Compressor package consists of several helium scroll compressors witch are originally used for driving GM cryocooler. Three segments of plate heat exchanger are adopted to cover the wide temperature range and the refrigeration power is produced by turbo expander. The developed refrigeration system is successfully operated at its target temperature of 77 K. In experiments, all parameters such as pressure, temperature, mass flow rate and valve opening are measured to investigate characteristics during cool-down process and normal state. The difference between design and real operation is discussed with measured experimental data. At normal state of 77 K operation, the developed reverse-Brayton refrigeration system shows 1.83 kW at 68.2 K of cold-end temperature.

Effect of test-caused degradation on the unavailability of standby safety components

  • S. Parsaei;A. Pirouzmand;M.R. Nematollahi;A. Ahmadi;K. Hadad
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.526-535
    • /
    • 2024
  • This paper proposes a safety-critical standby component unavailability model that contains aging effects caused by the elapsed time from installation, component degradation due to surveillance tests, and imperfect maintenance actions. An application of the model to a Motor-Operated Valve and a Motor-Driven Pump involved in the HPIS of a VVER/1000-V446 nuclear power plant is demonstrated and compared with other existing models at component and system levels. In addition, the effects of different unavailability models are reflected in the NPP's risk criterion, i.e., core damage frequency, over five maintenance periods. The results show that, compared with other models that do not simultaneously consider the full effects of degradation and maintenance impacts, the proposed model realistically evaluates the unavailabilities of the safety-related components and the involved systems as a plant age function. Therefore, it can effectively reflect the age-dependent CDF impact of a given testing and maintenance policy in a specified time horizon.