• 제목/요약/키워드: Power unbalance

검색결과 389건 처리시간 0.035초

전력저장시스템 기술개발 국외동향 분석 및 국내 활용방안 연구 (Study on the Oversea Technology Development of Electric Power Storage System and It's Domestic Application)

  • 최경식;양승권
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2008
  • As the technology of a large scale battery have advanced, it's application to the electric power network have been active in foreign country. By providing the electric power energy stored in the electric power storage system when needed, there are many advantages that it is able to reduce the gap between the electric power demand and supply for day and night to increase capacity factor, to upgrade the electric power quality degraded from the unbalance between power demand and supply and to compensate the fluctuation of wind power plant and photovoltaic power generation. In this study, the current application of electric power storage system using battery is introduced in detail, and I have thought out it's application fields based on the foreign examples. These are demand side response, upgrade of the power quality, stabilization of fluctuation of renewable energy and distributed generation for filling elapse.

  • PDF

선형 및 비선형 부하 혼합 운전시 유도전동기의 동작 분석 (Operation Analysis of Induction Motor under the Combination of Linear & Non-linear Loads)

  • 김종겸;박영진;이동주;김준호;이종한;정종호;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.65-67
    • /
    • 2006
  • This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system. Under the combination operation of single & three phase load, voltage unbalance will be generated and current unbalance will be more severe by the dropped voltage quality. All power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. Motors may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration.

  • PDF

DME/천연가스 HCCI 기관의 연소특성(기통 간 불균형과 EGR의 영향) (Combustion Characteristics of HCCI Engine Fueled DME and Natural Gas(Unbalance of Cylinder-to-Cylinder and Effect of EGR))

  • 정석호
    • 동력기계공학회지
    • /
    • 제14권3호
    • /
    • pp.13-18
    • /
    • 2010
  • HCCI engines fueled DME and natural gas have been studied on single-cylinder engine due to availability of reducing on $NO_X$ and PM simultaneously without deteriorating into high thermal efficiency, and thus it is clarified that higher maximum engine load is achieved as DME equivalence is smaller. In this study, combustion tests were accomplished on multi-cylinder engine for practical use of it. When minimum DME equivalence achieved maximum engine load on single-cylinder engine was applied to 4-cylinders engine, there was in unstable running condition that engine revolution fluctuated greatly and cyclically. It is the reason what misfire occurred intermittently with one the same as minimum DME equivalence on single-cylinder due to increase in energy for ignition at No. 1 cylinder with lower cylinder liner temperature. Maximum engine load was achieved by adopting EGR, though it decreased because of knocking at smaller engine load than single-cylinder due to increase in minimum DME equivalence.

3상 전압형 PWM 컨버터 운전시 전원측 리액터의 불평형을 고려한 보상법 (A Compensation Method considering Unbalance of Reactor at Source Side in Driving 3 Phase Voltage type PWM Converter)

  • 전지용;이사용;조유환;이근홍
    • 전력전자학회논문지
    • /
    • 제10권4호
    • /
    • pp.373-379
    • /
    • 2005
  • 본 논문에서는 인버터를 구동하는 용도의 직류전원장치에 대한 제어 알고리즘 개발을 목표로 하고 있으며, 구동과 회생기능을 갖는 전압형 PWM 컨버터에서 운전시 전원의 불평형을 보상하는 제어방법을 제안한다. 교류전원에 대하여 컨버터가 항상 평형상태를 유지하는 방법은 전류제어 루프에 의하여 불평형 상태를 보상하는 방법을 사용하였으며, 불평형의 제어는 전력변환기의 구성면에 있어서 각상의 리액턴스가 같지 않은 누설변압기 등의 사용을 가능하게 하므로 제안된 전력변환기의 하드웨어와 제어 알고리즘은 장치의 소형화와 효율향상에 기여할 것이다.

Unbalance Control Strategy of Boost Type Three-Phase to Single-Phase Matrix Converters Based on Lyapunov Function

  • Xu, Yu-xiang;Ge, Hong-juan;Guo, Hai
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.89-98
    • /
    • 2019
  • This paper analyzes the input side performance of a conventional three-phase to single-phase matrix converter (3-1MC). It also presents the input-side waveform quality under this topology. The suppression of low-frequency input current harmonics is studied using the 3-1MC plus capacitance compensation unit. The constraint between the modulation function of the output and compensation sides is analyzed, and the relations among the voltage utilization ratio and the output compensation capacitance, filter capacitors and other system parameters are deduced. For a 3-1MC without large-capacity energy storage, the system performance is susceptible to input voltage imbalance. This paper decouples the inner current of the 3-1MC using a Lyapunov function in the input positive and negative sequence bi-coordinate axes. Meanwhile, the outer loop adopts a voltage-weighted synthesis of the output and compensation sides as a cascade of control objects. Experiments show that this strategy suppresses the low-frequency input current harmonics caused by input voltage imbalance, and ensures that the system maintains good static and dynamic performances under input-unbalanced conditions. At the same time, the parameter selection and debugging methods are simple.

A 15kW Grid-Connected Battery Charging and Discharging System with AC Regeneration Function

  • Youn, Sun-Jae;Kim, Jun-Gu;Kim, Jae-Hyung;Won, Chung-Yuen;Na, Jong-Kuk
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.491-493
    • /
    • 2011
  • In this paper, a 15kW grid-connected battery charging and discharging system was proposed. AC regenerative device which consisted of an inverter using IGBTs and LCL filter transferred surplus power to grid. Phase locked loop(PLL) was used to resolve three-phase unbalance. AC regeneration function is able to improve the rate of energy use and the cost savings of energy is expected.

  • PDF

배전용 정지형 보상기의 개선된 직류단 커패시터 전압제어 (Improved dc-link capacitor voltage control of Distribution Static Compensator)

  • 김호열;최종우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.466-467
    • /
    • 2010
  • Researches about DSTATCOM are mainly divided two parts, one is the calculation of the load-side average active power and dc-link capacitor average voltage, the other part is the current control. This paper proposes a calculation of dc-link capacitor average voltage using improved method instead of conventional method using LPF (low pass filter). Through the theoretical analysis and simulation under unbalance loads and non-linear load, the proposed method is verified.

  • PDF

A Novel Multi-Level Inverter Configuration for High Voltage Conversion System

  • Suh, Bum-Seok;Lee, Yo-Han;Hyun, Dong-Seok
    • Journal of Electrical Engineering and information Science
    • /
    • 제1권2호
    • /
    • pp.109-118
    • /
    • 1996
  • This paper deals with a new multi-level high voltage source inverter with GTO Thyristors. Recently, a multi-level approach seems to be the best suited for implementing high voltage conversion systems because it leads to harmonic reduction and deals with safe high power conversion systems independent of the dynamic switching characteristics of each power semiconductor device. A conventional multi-level inverter has some problems; voltage unbalance between DC-link capacitors and larger blocking voltage across the inner switching devices. To solve these problems, the novel multi-level inverter structure is proposed.

  • PDF

An Integrated Compensation Algorithm for PCC Voltage Fluctuation and Unbalance with Variable Limit of Positive and Negative Sequence Currents

  • Im, Ji-Hoon;Song, Seung-Ho;Cho, Sung-Min
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.751-760
    • /
    • 2017
  • This paper proposes a point of common coupling (PCC) voltage compensation algorithm using a current limitation strategy for use in distributed generation (DG). The proposed strategy maintains the PCC voltage by prioritizing currents when an output current reference is larger than the current capacity of the power condition system (PCS) of the DG. With this strategy, the DG outputs the active current, reactive current, and the negative sequence current. The DG uses the reactive current for maintaining the PCC voltage within a normal range; the negative sequence current is used for reducing the PCC voltage unbalance. The proposed method was verified using PSIM simulation and experimental results.

3상 가변형 셀프 베어링 스텝모터의 제어 (Control of a 3-Phase VR Type Self-Bearing Step Motor)

  • 김대곤
    • 대한기계학회논문집A
    • /
    • 제25권12호
    • /
    • pp.1974-1980
    • /
    • 2001
  • The control algorithm of a new type self-bearing step motor is presented. The motor actuator is used for both motor and bearing functionality without any redundant coil windings or redundant electromagnets. The self$.$bearing step motor layout and its control method are described. A linearized farce-current-displacement relationship is derived. As the result of the unbalance response approach, the constant torque production is possible fur the supply current regulation algorithm. And even if the bearing functionality is added in the motor functionality, no additional current for bearing functionality is possible, and this leads to minimize the net power loss. Also, the unbalance response shows the independent bearing force and motor torque.