• Title/Summary/Keyword: Power transfer

Search Result 3,297, Processing Time 0.038 seconds

Design of Two-Dimensional Resonant Wireless Power Transfer Using 90˚ Phase Shifted Inputs (90˚ 입력위상의 변화를 통한 2차원 무선전력전송 구현)

  • Kim, Sanghwan;Seo, Chulhun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.70-74
    • /
    • 2015
  • In this paper, two-dimensional resonant transmitter and receiver for WPT is designed and implemented using method that use $90^{\circ}$ phase shifted input power to orthogonal transmitter. Mutual inductance is minimized by using proposed each orthogonal coil of receiver and the method that inputs $90^{\circ}$ phase shifted power is used to radiate magnetic energy into two dimension. This method facilitates two dimensional resonant WPT by solving power efficiency degradation problem according to location in general WPT. The resonance frequency is 6.78 MHz and the distance between transmitting and receiving resonator is 200 mm. The transfer efficiency of the proposed wireless power transfer system is higher than 40 % at all direction.

Reduction of Electromagnetic Field from Wireless Power Transfer Using a Series-Parallel Resonance Circuit Topology

  • Kim, Jong-Hoon;Kim, Hong-Seok;Kim, In-Myoung;Kim, Young-Il;Ahn, Seung-Young;Kim, Ji-Seong;Kim, Joung-Ho
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.3
    • /
    • pp.166-173
    • /
    • 2011
  • In this paper, we implemented and analyzed a wireless power transfer (WPT) system with a CSPR topology. CSPR refers to constant current source, series resonance circuit topology of a transmitting coil, parallel resonance circuit topology of a receiving coil, and pure resistive loading. The transmitting coil is coupled by a magnetic field to the receiving coil without wire. Although the electromotive force (emf) is small (about 4.5V), the voltage on load resistor is 148V, because a parallel resonance scheme was adopted for the receiving coil. The implemented WPT system is designed to be able to transfer up to 1 kW power and can operate a LED TV. Before the implementation, the EMF reduction mechanism based on the use of ferrite and a metal shield box was confirmed by an EM simulation and we found that the EMF can be suppressed dramatically by using this shield. The operating frequency of the implemented WPT system is 30.7kHz and the air gap between two coils is 150mm. The power transferred to the load resistor is 147W and the real power transfer efficiency is 66.4 %.

Numerical simulation of natural convection around the dome in the passive containment air-cooling system

  • Chunhui Dong;Shikang Chen;Ronghua Chen;Wenxi Tian;Suizheng Qiu;G.H. Su
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2997-3009
    • /
    • 2023
  • The Passive containment Air-cooling System (PAS) can effectively remove the decay heat of the modular small nuclear reactor after an accident. The details of natural convection around the dome, which is a key part of PAS, were investigated numerically in the present study. The thermal dynamics around the dome were studied through the temperature, pressure and velocity contours and the streamlines. Additionally, the formation of the buoyant plume at the top of the dome was investigated. The results show that with the increase of Ra, the lift-off point moves toward the bottom of the dome, and the eddy under the buoyant plume grows larger gradually, which enhances the heat transfer. And the heat transfer along the dome surface with different truncation angles was investigated. As the angle increases, the heat transfer coefficient becomes stronger as well. Consequently, a newly developed heat transfer correlation considering the influence of truncation angle for the dome is proposed based on the simulated results. This study could provide a better understanding of natural convection around the dome of PAS and the proposed correlation could also offer more predictive value in the improvement of nuclear safety.

Condensing Heat Transfer of Natural Refrigerants with Nanoparticles in Enhanced Tube (나노입자를 포함한 자연냉매의 마이크로 휜관 응축 열전달 특성)

  • Lee, H.S.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.19-25
    • /
    • 2008
  • This paper deals with the heat transfer and pressure drop characteristics of R-290 (Propane), R-600a (Iso-butane) and R-1270 (Propylene) as an environment friendly refrigerant and R-22 as a HCFC's refrigerant for condensing. The test section is a horizontal double pipe heat exchanger. Condensing heat transfer and pressure drop measurements were Peformed for 12.70 mm micro-fin tube and compared with the results in smooth tube. The local condensing heat transfer coefficients of hydrocarbon refrigerants were superior to those of R-22 and the maximum increasing rate of heat transfer coefficient was found in R-600a. The average condensing heat transfer coefficients in hydrocarbon refrigerants showed 20 to 28% higher values than those of R-22. Hydrocarbon refrigerants have a higher pressure drop than that of R-22 with respect to refrigerant qualify and mass flux. Also, the condensing heat transfer coefficient and pressure drop of working fluids in smooth and micro-fin tube were compared. The heat transfer enhancement factor (EF) between smooth and micro-fin tube varied from 2.2 to 2.6 in all experimental conditions.

  • PDF

Factors influencing inter-hospital transfer time - A private ambulance - (병원 간 전원 시간에 영향을 미치는 요인 - 일개 사설이송단을 중심으로 -)

  • Kim, Seong-Ju
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1215-1223
    • /
    • 2019
  • Purpose: This study is to figure out not only the characteristics relating to transfer time of inter-hospital transfer patient which is transferred by a private ambulance, but also factors influencing the transfer time. Methods: In this study, an analysis of 750 patients with high severity levels among those transferred to another hospital by a private ambulance in Busan for whole year of 2017. Results: The results showed that the following factors significantly influence the total inter-hospital transfer time: Ambulance crew (${\beta}=10.525$, p=.001) and patient and carer (${\beta}=37.606$, p<.001) when setting a doctor (selecting a medical institution) as a criterion; availability of the specialized care (${\beta}=12.435$, p=.008) when setting the near distance (reason for selecting a hospital for transfer) as a criterion. The explanatory power of this analysis was R2=0.423, whereas the explanatory power of calibration was R2=0.411. Conclusions: Factors that increase the total inter-hospital transfer time were the ambulance crew, and patient and carer's selecting a medical institution, and the reason for selecting a hospital where enables to offer the specialized care services.

Characteristic analysis of inductive contactless power transformer laid under the road/railway for performance improvement (도로/궤도 매립형 무접촉 집전장치의 전력전달 성능개선을 위한 특성해석)

  • Han Kyung-Hee;Lee Byung-Song;Baek Soo-Hyun
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1425-1430
    • /
    • 2004
  • In this paper, the inductive power transformer using electromagnetic induction for the road/railway applied to contactless power transfer system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The proposed the inductive power transformer is used for the light railway/road transportation system. which has a large air-gap and demands a large electrical power capability. But. low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding, which was divided in half to increase both output current and output voltage was suggested. In addition, the performance of inductive power transformer to alignment condition between the primary power line and the inductive power transformer was verified by computer simulation of 2kW model.

  • PDF

지자기장 및 지자기 전달함수의 시간적 변동성 분석

  • Yang Jun-Mo;Lee Deok-Gi;Gwon Byeong-Du;Ryu Yong-Gyu;Yun Yong-Hun
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.103-113
    • /
    • 2004
  • We investigate the time-variational characteristics of power spectrum and transfer function of geomagnetic field by robust estimation technique. In the case of power spectrums of geomagnetic field, there are some the periodic fluctuations related with solar activity, Meanwhile, the geomagnetic transfer function shows so considerable weak time-variational fluctuation that the estimations of transfer function seem to be comparatively stable in time-variant view.

  • PDF

Power stage for Contact-less Induction Charging (비접촉식 충전기의 전력 전달부 설계)

  • 이민철;최배근;홍영욱;조규형
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2939-2942
    • /
    • 2003
  • A new contactless Li-ion battery charging system was proposed. The conventional methods for charging Li-ion battery have some weak points. For example, there can be a contact failure, a poor waterproof, and a difficulty to standardize the battery charging systems. The new proposed system can overcome these weak points. The new charging system is composed of power transfer part and data transfer part. This paper focuses on the power transfer part for contactless battery charging. The power stage is mainly composed of PPRC(Push-pull Parallel Resonant Converter) and flyback converter. The new method of chaging Li-ion battery was proposed and PPRC + flyback-boost topology was analyzed. The proposed toplogy was tested under the constant voltage control and the constant current control which are adequate for charging Li-ion battery.

  • PDF

Evaluation of Optimal Transfer Capability in Power System Interconnection (연계된 계통간의 최적 송전 용량 산정)

  • Son, Hyun-Il;Bae, In-Su;Jeon, Dong-Hoon;Kim, Jin-O
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.679-685
    • /
    • 2010
  • As the electrical power industry is restructured, the electrical power exchange is becoming extended. One of the key information used to determine how much power can be transferred through the network is known as available transfer capability (ATC). To calculate ATC, traditional deterministic approach is based on the severest case, but the approach has the complexity of procedure. Therefore, novel approach for ATC calculation is proposed using cost-optimization method, well-being method and risk-benefit method in this paper. This paper proposes the optimal transfer capability of HVDC system between mainland and a separated island in Korea through these three methods. These methods will consider production cost, wheeling charge through HVDC system and outage cost with one depth (N-1 contingency).

Evaluation of Optimal Transfer Capability in Power System interconnection (연계된 계통간의 최적 송전용량 산정)

  • Son, Hyun-Il;Choi, Ah-Reum;Lee, Sung-Hoon;Kim, Jin-O;Jeon, Dong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.195_196
    • /
    • 2009
  • As the electrical power industry is restructured, the electrical power exchange is becoming extended. One of the key information used to determine how much power can be transferred through the network is known as available transfer capability (ATC). To calculate ATC, traditional deterministic approach is based on the severest case, but the approach has the complexity of procedure. Therefore, novel approach for ATC calculation is proposed using cost-optimization method in this paper, and is compared with well-being method and risk-benefit method. This paper proposes the optimal transfer capability of HVDC system between mainland and a separated island in Korea through these three methods. These methods will consider production cost, wheeling charge through HVDC system and outage cost with one depth (N-1 contingency).

  • PDF