• Title/Summary/Keyword: Power system network analysis

Search Result 768, Processing Time 0.03 seconds

A Proposal of Combat Power Measurement Model of Army Warfare Information System Using Network Power based on Social Network Analysis (SNA 기반 네트워크 파워를 이용한 지상전장정보체계 전투력 효과측정 모델제안)

  • Jung, Chi-Young;Lee, Jae-Yeong
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.36 no.4
    • /
    • pp.1-16
    • /
    • 2011
  • It is important not only to introduce the C4I(Command and Control, Communication, Computer, Intelligence) system for realizing the NCW(Network Centric Warfare) but also to evaluate the synergistic effect by the C4I system. However, the study effort for evaluating the system's synergistic effect is insufficient compared with introducing the system. Therefore, in this paper, we proposed a model that measures the synergistic effect of combat power by the warfare information system. To measure the synergistic effect of warfare information system, the network power must be considered, so we also proposed a new methodology for measurement of network power based on SNA(Social Network Analysis), not Metcalfe's law. A model we proposed is a model that measures the raised combat power by the network effectiveness. The methodology and model we proposed in this paper will be used usefully to analyze the practical effect of constructing future warfare information system.

Power Flow Calculation Method of DC Distribution Network for Actual Power System

  • Kim, Juyong;Cho, Jintae;Kim, Hongjoo;Cho, Youngpyo;Lee, Hansang
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.419-425
    • /
    • 2020
  • DC distribution system has been evaluated as an excellent one in comparison with existing AC distribution network because it needs fewer power conversion stages and the full capacity of the equipment can be used without consideration for power factor. Recently, research and development on the implementation of DC distribution networks have been progressed globally based on the rapid advancement in power-electronics technology, and the technological developments from the viewpoint of infrastructure are also in progress. However, to configure a distribution network which is a distribution line for DC, more accurate and rapid introduction of analysis technology is needed for the monitoring, control and operation of the system, which ensure the system run flexible and efficiently. However, in case of a bipolar DC distribution network, there are two buses acting as slack buses, so the Jacobian matrix cannot be configured. Without solving this problem, DC distribution network cannot be operated when the network is unbalanced. Therefore, this paper presented a comprehensive method of analysis with consideration of operating elements which are directly connected between neutral electric potential caused by the unbalanced of load in DC distribution network with bipolar structure.

Calculation of Network Analysis and Fault Decision using Equality Constraint Condition with MATLAB (등호제약조건을 이용한 계통 해석 및 고장판단 계산 구현)

  • Yang, Min-Uk;Kim, Kern-Joong;Hwang, In-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2101-2106
    • /
    • 2009
  • The power system state estimation and prediction are very important for operation. Because that accidents of the Power system are the cause that many devices and etc are damaged. Currently, almost every power systems have 2nd,3rd back-upsystem for prevention of accident. But prevention of accident by miss-operation, due to operator or miss data, has not acounter plan. Because, we need to estimate the power system for correcting miss data and preventing miss operation by operator. We suggest algorithm for integrity of power system network data.

Simulation and Analysis of the Network Traffic of a Power Infrastructure Defense System (광역 방어시스템의 통신 트래픽 모사와 분석)

  • Baek, Yoon-Ki;Yi, Keon-Young
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.179-180
    • /
    • 2006
  • The real time monitoring of the power systems covering wide area are essential for the stable operation and control of the power system. Synchronized phasor measurement is a key for the precise monitoring and control of the power systems. In this paper, to suggest an appropriate network topology of Power Infrastructure Defense System(PIDS) and to estimate the maximum network bandwidth with using the network analyzer, we simulate a PIDS and analyze the network traffic.

  • PDF

EMTP simulation of 345kv Substation in large network using newly developed Thevenin equivalent network (345kv 미금 변전소 외부 계통의 등가축약 기법을 이용한 EMTP 모델링에 관한 연구)

  • Jeong, Ki-Seok;Baek, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.244-246
    • /
    • 2008
  • EMTP-RV is the very powerful program to analyze the dynamic operation of the power system. To use this package in the large complex power system, it is very important to simplify the power system to simple equivalent network. In our study the 100 MVA STATCOM is placed at 345kV "MIGUM" which is the one of the 345kV substations of the Korean Electric Power System that is consist of more than 1000 bus. MIGUM substation is connected with 7 separated transmission lines to main Korean Electric power system. We developed a new method to simplify the network except the substation that we want to analysis. The power system outside the 345kV substation is modeled into the equivalent network. The loop network outside the substation can be modeled to simplified Thevenin equivalent network. The proposed method is applied to IEEE-14 Reliability Test System and the results shows the effectiveness of the method.

  • PDF

A Study on the Fault Current Characteristics for the Utility Application of HTS Power cable (초전도 전력케이블의 전력계통 적용을 위한 고장전류 특성에 관한 연구)

  • Kim, Jae-Ho;Park, Min-Won;Sim, Ki-Deok;Cho, Jeon-Wook;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.75-76
    • /
    • 2007
  • Several kinds of High Temperature Superconducting(HTS) power cables have already been developed and evaluated for use in the utility power network. HTS power cable is expected to be used as a very powerful energy delivery system supplying electric power for densely populated cities in the near future, because HTS power cable is capable of the high current density delivery with low AC loss and the size effect comparing with the conventional cable whose capacity is same. Before applying the HTS power cable to real utility network system analysis should be carried out by some simulation tools. Hereby the electrical power system analysis is very important for the practical use of HTS power devices. In this paper, authors propose a real-time simulation method which incorporates a real HTS tapes into the simulated 22.9kV utility power network system using Real Time Digital Simulator(RTDS). For the simulation analysis, a test sample of HTS tapes was actually manufactured, and the transient phenomenon of HTS power cable system was analyzed in the simulated utility power network.

  • PDF

Reliability analysis of nuclear safety-class DCS based on T-S fuzzy fault tree and Bayesian network

  • Xu Zhang;Zhiguang Deng;Yifan Jian;Qichang Huang;Hao Peng;Quan Ma
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1901-1910
    • /
    • 2023
  • The safety-class (1E) digital control system (DCS) of nuclear power plant characterized structural multiple redundancies, therefore, it is important to quantitatively evaluate the reliability of DCS in different degree of backup loss. In this paper, a reliability evaluation model based on T-S fuzzy fault tree (FT) is proposed for 1E DCS of nuclear power plant, in which the connection relationship between components is described by T-S fuzzy gates. Specifically, an output rejection control system is chosen as an example, based on the T-S fuzzy FT model, the key indicators such as probabilistic importance are calculated, and for a further discussion, the T-S fuzzy FT model is transformed into Bayesian Network(BN) equivalently, and the fault diagnosis based on probabilistic analysis is accomplished. Combined with the analysis of actual objects, the effectiveness of proposed method is proved.

Development of Educational Simulator for Novel Network Reduction (송전망 축약을 위한 교육용 시뮬레이터 개발)

  • Kim, Hyun-Houng;Lee, Woo-Nam;Kim, Wook;Park, Jong-Bae;Shin, Joong-Rin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1902-1910
    • /
    • 2009
  • This paper presents a graphical windows-based program for the education and training for novel network reduction. The object of developed simulator is to provide users with a simple and useable tool for gaining an intuitive feel for power system analysis. The developed simulator consists of the main module (MMI,GUI), the location marginal price module (LMP), the clustering module and network reduction module. Each module has a separate graphical and interactive interfacing window. The developed simulator needs with the PSS/E input data format, generator cost function, location information. Line admittances of reduced network was determined by using the power flow method(Newton-Raphson). So line flow of reduced network is almost same to original power system. Results of reduced network are compared on the window in the tabular format. Therefore, the developed simulator can be utilized as a useful tool for effective education and training for power system analysis.

Calculation of Generator Reactive Reserve Considering Network Configuration (전력계통 구조를 고려한 발전기 무효예비력 산정)

  • Seo, Sang-Soo;Kim, Dae-Jeong;Choi, Yoon-Hyuk;Lee, Byong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.711-716
    • /
    • 2011
  • This paper defines a generator reactive reserve considering power system network. Conventional generator reserve is calculated by the difference between the maximum reactive power output of generator and the current reactive power of generator. However, all generators could not affect on the whole power system. Thus, the effective generators should be selected by sensitivity analysis. The sensitivity depends on network configuration is the relation between generator reactive power outputs and reactive power loads. Using the sensitivity, the effective generator reactive reserve can be calculated.

Analysis of Power Transmission Characteristics for Hydro-mechanical Transmission Using Extended Tetwork theory (확장된 네트워크기법을 이용한 정유압 기계식 번속장치의 동력전달 특성해석)

  • Kim, Won;Chung, Soon-Bae;Kim, Hyun-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.5
    • /
    • pp.1426-1435
    • /
    • 1996
  • In this paper. a network theory for generaltransmission systme was extended considering the direction of power flow. Also, a modified network model was suggested for a node with 4 shafts in order to verify the power flow. Based on the extended network theory, a simulation program was developed to analyze a hydro-mecaanical tranmission(HMT) system consistion of two hydrostatic pump motors, severeal planetary gear trains steer differential gear. The simulation result showed that the extendednotwork analysis program develped can predict the power circulation as well as the magnitude of torque and speed for each transmission element and can be used design tool for genaral power transmission system.