• 제목/요약/키워드: Power system monitoring

검색결과 1,933건 처리시간 0.035초

대형 풍력터빈을 위한 무인 원격감시시스템 개발 (Development of Unmanned Remote Monitoring System for MW Class Wind Turbines)

  • 박준영;김범주;이재경
    • 제어로봇시스템학회논문지
    • /
    • 제17권5호
    • /
    • pp.412-418
    • /
    • 2011
  • The scale of wind turbines has continuously increased over the last decade. Especially, the rapid growth of the rotor diameter has brought about the increase of the tower height and the load on the rotor blade, as can be seen in the case of a 5MW class wind turbine with 126m rotor diameter. This trend means the increasing possibility of system failure. In addition to that, it is impossible for human operators to stay and manage all the turbines in the case of a large-scale wind farm. For these reasons, the operation and maintenance technology is getting more importance. In this paper, we present an unmanned remote monitoring system for MW class wind turbines and its application to YeungHeung wind test bed.

전력 설비 감시 시스템들 간의 정보 교환 기법에 관한 연구 (A Study on the Information Exchange Technique among Electric Power Facilities and Monitoring Systems)

  • 홍창호;박찬엄;이승철;문운철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.453-456
    • /
    • 2006
  • In this paper, we introduce the design and implementation of Information exchange technique among power system facilities and/or their monitoring systems based on Universal Description, Discovery and Integration Service and Simple Object Access Protocol. The rapid progresses in high speed network, 4G web language S/W and embedded H/W enabled faster and easier communications among electric power systems monitoring facilities. However, each facility or system has its own specific protocol like RS-232 and RS-486, which somewhat limits the capability of flexible information exchange among thor In this paper, we try to demonstrate the potential of utilizing the SOAP and UDDI services in exchanging the metadata and possibly high abstraction level informations among electric power facilities and/or their monitoring systems.

  • PDF

전력용 변압기 예방진단 시스템의 실 계통 적용 연구 (A study on field test of diagnostic Monitoring System for Power Transformers)

  • 김용한;이창용;황보승욱;신용택;박귀철;박균수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.91-93
    • /
    • 2004
  • This study presents recent trends on the on-line monitoring and diagnostic systems for oil-immersed transformers. Specially, our system on Yeo Su thermal power plant is introduced for high sensitivity and accuracy of ours. It is combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

생체신호 무선 송수신을 위한 소형,저전력 통신시스템 개발 (Low-power wireless communication System for Biosignal transmission)

  • 이강휘;이정환;김경섭;김동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.370-372
    • /
    • 2005
  • Inconveniences which might arise in transmitting measured biological data based on cable protocols generally are recognized critical points in tele-monitoring environment and also restrict the mobility of the user. a. Especially, activity monitoring which is importantly recognized as a core parameter in ubiquitous healthcare arena and weight management, pervasive and wireless measuring technology is most needed. In this paper, we would like to suggest lower power, miniaturized communication system in order to solve the above problems. The suggested system is powered by small coin-size battery. Also, The suggested system is compared with a blue-tooth module which is generally available in the commercial market. Even though, the suggested system didn't have higher transmission rate, its low power consumption make the suggested system would be feasible in ubiquitous monitoring of biological signals in ubiquitous healthcare arena.

  • PDF

양수발전소 SFC 감시시스템 개발 (Development of monitoring system of static frequency converter in pumped storage power plant)

  • 이주현;임익헌;류호선;신만수;김봉석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.213-215
    • /
    • 2006
  • A static frequency converter(SFC) in a pumped storage power plant is important equipment for converting electric motor kinetic energy into electric Bower. A SFC monitoring system consists of high voltage thyristor firing equipment, fault detection module, data gathering module, real time data processing equipment and man machine Interface system. This paper describes SFC system overview, developed SFC monitoring system configuration including system characteristics. and successful application result to San-Cheong pumped storage power plant.

  • PDF

기기별 전력 모니터링 시스템 개발에 관한 연구 (A Study on Electric Power Monitoring System per Appliance)

  • 박성욱;김종식;임수진;황보세희;손준익;이인용;왕보현
    • 한국지능시스템학회논문지
    • /
    • 제20권5호
    • /
    • pp.638-644
    • /
    • 2010
  • 본 연구에서는 일반 가정에서 Smart Grid를 통하여 누릴 수 있는 서비스를 발굴하고, 이러한 서비스를 구현할 수 있는 기기별 전력 모니터링 시스템을 구현하였으며, 모니터링한 데이터를 분석하였다. 기기별 전력 사용현황을 수집하고 이를 분석함으로써, 모니터링 시스템에 표시되고 있는 전력사용현황이 어떤 기기의 전력사용현황인지 사전에 정의된 프로토콜 없이 알 수 있다. 나아가서 전력 절감 방법 제시, 지능적인 대기전력 차단 및 복구, 기기의 이상여부 감시와 같은 서비스를 구현할 수 있을 것이다. 본 연구에서는 이러한 시나리오의 실현 가능성을 점검하기 위해 기기별 전력 모니터링 시스템을 개발하여 가정 내 전력소비의 대부분을 차지하는 냉장고, 전기밥솥, TV, 세탁기 샘플에 대하여 전력소비패턴을 수집하여 database화 하였다. 또한 이 database를 분석하여 제시한 서비스들을 구현하는데 필요한 기본 기능인 기기식별이 전력사용 패턴분석을 통하여 가능함을 보였다.

On-line Temperature Monitoring of the GIS Contacts Based on Infrared Sensing Technology

  • Li, Qingmin;Cong, Haoxi;Xing, Jinyuan;Qi, Bo;Li, Chengrong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1385-1393
    • /
    • 2014
  • Gas insulated switchgear (GIS) is widely used in the power systems, however, the contacts overheating of the inside circuit breaker or disconnector may be a potential cause of developing accidents. As the temperature of the contacts cannot be directly acquired due to existence of the metallic shield, an infrared sensor is adopted to directly measure the temperature of the shield and then the contacts temperature can be indirectly obtained by data fitting, based on which the on-line temperature monitoring technology specifically for GIS contacts based on infrared sensing is proposed in this paper. A real GIS test platform is constructed and experimental studies are carried out to account for the influential factors that affect the accuracy of the infrared temperature measurement. A heat transfer model of the GIS module is also developed, together with experimental studies, the nonlinear temperature relationship among the contacts, the metallic shield and the environment based on a neural network algorithm is established. Finally, an integrated on-line temperature monitoring system for the GIS contacts is developed for on-site applications.

전력품질 모니터링 시스템 : User-Friendly-GUI 및 분석 그래프 표준 (A Power Quality Monitoring System(PQMS) : A Standard of User-Friendly-GUI & Analysis Graphic Representation)

  • 김영일;한진희;윤태욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.127-130
    • /
    • 2002
  • Recently, with the increasing use of power semiconductors and microprocessors which are very sensitive to little change of power quality and for coping positively with anticipating power quality disputes between power providers and consumers which are possible to occur by of power market being formed, the power quality problem has gained preponderance among the contemporary research areas. To serve these purposes, the integrated system has been researched and developed for power quality analysis and monitoring, which provides speedy and powerful functions by the growth of computer hardware and information technology. But the advent of fast and lower price hardware make little difference in an application on many systems. As a result, the key issues of constructing power quality monitoring system are in the management of data obtained, accurate algorithms, graphic representation and user-friendly-environment for easy and clear analysis results. So, in this paper it will be introduced that the standard of user-friendly-GUI(Graphic User Interface) and analysis graphic representation for intuitive understanding of results from power quality analysis based on consideration of several systems currently being in use.

  • PDF

Development for Life Assessment System for Pipes of Thermal Power Plants

  • Hyun, Jung-Seob;Heo, Jae-Sil;Kim, Doo-Young;Park, Min-Gyu
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.583-588
    • /
    • 2016
  • The high-temperature steam pipes of thermal power plants are subjected to severe conditions such as creep and fatigue due to the power plant frequently being started up and shut down. To prevent critical pipes from serious damage and possible failure, inspection methods such as computational analysis and online piping displacement monitoring have been developed. However, these methods are limited in that they cannot determine the life consumption rate of a critical pipe precisely. Therefore, we set out to develop a life assessment system, based on a three-dimensional piping displacement monitoring system, which is capable of evaluating the life consumption rate of a critical pipe. This system was installed at the "M" thermal power plant in Malaysia, and was shown to operate well in practice. The results of this study are expected to contribute to the increase safety of piping systems by minimizing stress and extending the actual life of critical piping.

Synchro-Phasor 기반의 Smart WAMAC 인프라 아키텍쳐 설계 (Designing of Smart WAMAC Infra Architecture based on Synchro-Phasor)

  • 김지영;우덕제;김상태;최미화;김용광
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1549-1559
    • /
    • 2010
  • Modern power system is operated and managed in closed network environment with treating a great variety of data, and requirement of real time power system data is more increasing. However, it is difficult for operators to fast evaluate the condition of power system using only isolation network system such as SCADA or EMS regarding unexpecting situations occurring. Recent technology achievement in areas of distributed computing, networking high speed communications and digital control as well as the availability of accurate GPS time source are rapidly becoming the enabling factors for the development of a new generation of real time power grid monitoring tools. In this paper, architecture of WAMAC which is the wide area monitoring and control system not only to control but also to monitoring in real time is proposed and the plan of integration interface with legacy system such as EMS for providing power system analysis base data effectively is suggested.