• Title/Summary/Keyword: Power saving

Search Result 1,280, Processing Time 0.024 seconds

Design of Asymmetric Pre-swirl Stator for LNG Carrier according to Variation of Stator Shapes (날개의 형상 변화에 따른 LNG선용 비대칭 전류고정날개 설계)

  • Lee, Choel-Min;Shin, Yong-Jin;Kim, Moon-Chan;Choi, Jung-Eun;Chun, Ho-Hwan
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.53 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • Recently researchers are conducting a lot of research related to EEDI in order to satisfy IMO resolution MEPC. Especially they are interested in design of energy saving device. This paper is to design the asymmetric pre-swirl stator for 160K LNG carrier in order to reduce energy. Two types of the asymmetric pre-swirl stator are taken into account; constant and variable pitch angle stators. “constant” and “variable” mean state that the pitch of stators change by radius. The dimensions of the stators are initially determined using potential-flow code. The propulsion performances of the stators are predicted using viscous-flow code. The model test is carried out in towing tank in PNU. Prediction of ship performance generally follow ITTC recommended. Ship wake prediction was done by two method, ITTC 1978 and ITTC 1999. Therefore propulsion performances were compared ITTC 1978 with ITTC 1999 methods. Comparison components are delivered power and thrust deduction coefficient of the model. Final pre-swirl stator is selected by comparing experiment and CFD.

Integration of Express·Intercity Bus Terminal and Highway Service Area: A Study of the Estimated Tangible Value Addition (고속·시외버스 터미널 및 고속도로 휴게소의 통폐합 운영에 따른 편익가치 산정에 대한 연구)

  • Jang, Jae min;Han, Jung hun
    • International Journal of Highway Engineering
    • /
    • v.19 no.2
    • /
    • pp.143-152
    • /
    • 2017
  • PURPOSES : This study intends to estimate the tangible benefits derived from the integration of operations of an Express Intercity Bus Terminal and a Highway Service Area. METHODS: For the study, a highway service area was chosen to function as a bus terminal, integrating its services with that of a nearby bus terminal plagued by operating losses. The exercise also helped improve mobility owing to the introduction of local buses between the terminals and utilization of the existing infrastructure such as rest areas. Thus, a terminal that was not being utilized for its intended functionality was integrated with an existing facility to improve the utilization of both and subsequently aid local development. The impact of the exercise was then measured by evaluating the variation in utilization efficiency, operating costs, travel time between two regions (Seoul-Jeomchon and Seoul-Geumsan), and the social costs before and after the integration of the two facilities. RESULTS :The impact of the integration was an increase in utilization efficiency, a decrease in operating cost, a decrease in travel time, and a decrease in social cost in both the regions. The benefits of improved utilization and cost saving can be passed on to the citizens in the form of discounts. A local power generation facility will eventually replace the bus terminal, which can revitalize the local economy. CONCLUSIONS :The integration of the highway service area with the bus terminal is expected to have a win-win effect on the passengers as well as the operators. The study also proposes a sustainable strategic plan for existing terminals and rest areas to implement a method to compete with KTX transportation.

Evaluation of Applicability of Renewable Energy in Controlled Horticulture Farms -Centering on Economic Analysis of Geothermal.Solar Powered- (시설원예농가의 재생에너지 적용가능성평가 -지열.태양광의 경제성 분석을 중심으로-)

  • Kim, Tae-Ho;Yoon, Sung-Yee
    • Korean Journal of Organic Agriculture
    • /
    • v.20 no.3
    • /
    • pp.267-282
    • /
    • 2012
  • In this study, RPS system, one of the renewable energy support systems, is utilized for economic analysis of solar generation equipment and the fuel cost savings plan for controlled horticulture farms with high fuel-cost dependency and facility applicability were evaluated. On the exterior of the upper layer of glass greenhouse (9917$m^2$) of controlled horticulture farms using bunker C oil, half of the area (4958$m^2$) was utilized for theoretical installation and operation of 450kW-level solar power generator, and as the result, first, the effect of investment cost only of solar generation system was found to be quite excellent, but it was analyzed that there were limits to saving the fuel costs of the controlled horticulture farms. Second, when geothermal system was first introduced in the farm and solar system was additionally introduced, it was analyzed that the effect of introducing solar system was excellent. In order to apply such effects to the sites of farming, partial supplementation of RPS system which is being uniformly applied regardless of the purpose of renewable energy is necessary. When the subject of use directly install facilities where it is directly connected to national added-value such as food security created by the farming industry, it is necessary to introduce appropriate system that corresponds to such. Moreover, it was studied that the quick development of demonstrative complex that can practically evaluate the applicability of renewable energy in farming industry and interest and preparation of related institutions in financial support structure for its site application would lead to success.

The Effect of Soil Warming on the Greenhouse Heating Load (지중가온이 온실의 난방부하에 미치는 영향)

  • Nam, Sang-Woon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.5
    • /
    • pp.51-60
    • /
    • 2006
  • In order to examine the heat transfer characteristic of a soil warming system and effects of soil warming on the greenhouse heating load, control experiments were performed in two greenhouses covered with double polyethylene film. One treated the soil warming with an electric heat wire and the other treated a control. Inside and outside air temperature, soil temperature and heat flux, and heating energy consumption were measured under the set point of heating temperature of $5,\;10,\;15,\;and\;20^{\circ}C$, respectively. Soil temperatures in a soil warming treatment were observed $4.1\;to\;4.9^{\circ}C$ higher than a control. Heating energy consumptions decreased by 14.6 to 30.8% in a soil warming treatment. As the set point of heating temperature became lower, the rate of decrease in the heating energy consumptions increased. The percentage of soil heat flux in total heating load was -49.4 to 24.4% and as the set point of heating temperature became higher, the percentage increased. When the set point of heating temperature was low in a soil warming treatment, the soil heat flux load was minus value and it had an effect on reducing the heating load. Soil heat flux loads showed in proportion to the air temperature difference between the inside and outside of greenhouse but they showed big difference according to the soil warming treatment. So new model for estimation of the soil heat flux load should be introduced. Convective heat transfer coefficients were in proportion to the 1/3 power of temperature difference between the soil surface and the inside air. They were $3.41\;to\;12.42\;W/m^{2}^{\circ}C$ in their temperature difference of $0\;to\;10^{\circ}C$. Radiative heat loss from soil surface in greenhouse was about 66 to 130% of total heating load. To cut the radiation loss by the use of thermal curtains must be able to contribute for the energy saving in greenhouse.

TAS: TCP-Aware Sub-layer over IEEE 802.11-based wireless LANs (IEEE 802.11 기반 무선랜에서 TCP 인진서브 계층 TAS)

  • Choi, Nak-Jung;Jung, Ha-Kyung;Ryu, Ji-Ho;Seok, Yong-Ho;Choi, Yang-Hee;Kwon, Tae-Kyoung
    • Journal of KIISE:Information Networking
    • /
    • v.33 no.5
    • /
    • pp.355-368
    • /
    • 2006
  • This paper introduces a new split-TCP approach for improving TCP performance over IEEE 802.11-based wireless LANs. TCP over wireless LANs differently from wired networks is not aggressive, which is a fundamental reason for poor performance. Therefore, we propose TAS (TCP-Aware Sub-layer) to migigate this problem. Our scheme extends the split-connection approach that divides a connection into two different connections at a split point such as an access point (AP). Using TAS, a wireless node emulates TCP ACK packets using MAC ACK frames, instead of receiving real TCP ACK packets. We compared TAS with both normal TCP and I-TCP (Indirect TCP) by NS2 simulation. Results show that TAS achieves higher throughput, more fair resource allocation and, in power-saving mode, shorter delays.

Analysis of Characteristics of White LED Light Source for TV Lighting (TV 조명용 백색 LED의 광원 특성 분석)

  • Lee, Kook-Se;Moon, Nam-Mee
    • Journal of Broadcast Engineering
    • /
    • v.15 no.4
    • /
    • pp.461-473
    • /
    • 2010
  • Since eco friendly and power saving products recently got into the limelight for the protection of environment, LED light technology has caught much of attention as the next generation broadcasting lighting. The newly introduced light source has such advantages as higher efficiency, longer life and its slim and compact forms leading to conveniency in installations. When combined with digital light control it gives more dynamic and various features to lighting. In this paper, used CIE standard for measuring light sources by their purposes and forms to make a comparative analysis of spectral distribution and color rendition of LED light source to those of existing lighting systems. By means of the cast shadowing and color reproduction tests I also tried to figure out the effects of LED lighting design on TV visuals where higher quality is crucial with the audience's increasing demands for quality image.

Vibration characteristics of endodontic motors with different motion: reciprocation and conventional rotation (왕복운동 및 회전운동 근관성형용 전동모터 간의 진동 양상 비교)

  • Jeon, Yeong-Ju;Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee;Chang, Hoon-Sang
    • The Journal of the Korean dental association
    • /
    • v.52 no.12
    • /
    • pp.734-743
    • /
    • 2014
  • Objectives: By introduced reciprocation motion file in dentistry, dentists benefit simple canal shaping procedure and time-saving. But, reciprocation motion generates uncomfortable vibration to doctors and patients. Because there was no study about this consideration, this study compared vibration pattern and power generated from reciprocation motion motor and conventional rotary motor. Materials & Methods: One conventional rotary motor; X-Smart (Dentsply Maillefer, Ballaigues, Switzerland); and two reciprocating motors; WaveOne Motor (Dentsply Maillefer, Ballaigues, Switzerland) and X-SMART PLUS (Dentsply Maillefer, Ballaigues, Switzerland); were used in this study. Triaxial $ICP^{(R)}$ Accelerometer (Model 356A12, PCB piezotronics, New York, USA) was attached on motor's handpiece head, and was measured tri-axial vibratory acceleration with NI Sound and Vibration Assistant 2009 software (National Instruments, Texas, USA). Mean vibratory acceleration and maximum vibratory acceleration was measured on fixed position and handed position. The results of vibratory acceleration were statistically analyzed using ANOVA and multiple comparisons are made using Turkey's test at p<0.05 level. Results: Reciprocating motors showed higher mean vibratory acceleration and maximum vibratory acceleration than conventional rotary motor (p<0.05). Between reciprocating motors, X-SMART PLUS had lower mean vibratory acceleration and maximum vibratory acceleration than WaveOne Motor (p<0.05). Conclusion: Reciprocating motors generate more vibration than conventional rotary motor. Further study about effect of vibration to dentist and patient is needed. And it seems to be necessary to make a standard about vibration level in endodontic motors.

Simplification of Device-Triggered Reporting Procedure on 3GPP GERAN Cellular IoT Communications (3GPP GERAN CIoT 환경에서 디바이스 Triggering 기반 Reporting 절차 간소화 방안)

  • Kim, Jun Suk;Shin, Jung Wan;Chung, Min Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.1
    • /
    • pp.80-83
    • /
    • 2016
  • In this paper, a simplified uplink transmission procedure is proposed for reducing energy consumption and improving lifetime of CIoT devices. In the proposed procedure, the CIoT devices register information on their service and traffic to the networks, and the networks statically allocate pre-defined amounts of radio resources when the CIoT devices have requested permission for their uplink transmissions. This paper provides details of the proposed procedure comparing with those of the current GSM procedure, and defines detailed operations of the devices and the networks for the proposed one. This shows that the proposed scheme can effectively support CIoT services on GSM networks.

A Study on the Power Saving Fraction of Site Electrical Load depending on the installation area of PV system in Apartment Complex (공동주택 단지 배치유형별 PV시스템 최적 설치면적 및 전기부하 기여율 평가 연구)

  • Yoon, Jong-Ho;Park, Jae-Sung;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.60-66
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex through the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performed with the hourly simulations of total received insolation on each surface considering the shading effect of buildings. Electrical load profile of typical Korean apartments were investigated for the load matching analysis. To calculate an annual total PV output, we used MERIT program which is a hourly based load matching tool developed by ESRD. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending on a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡtype revealed the best option for the maximum output of PV system.

A study on non-response bias adjusted estimation in business survey (사업체조사에서의 무응답 편향보정 추정에 관한 연구)

  • Chung, Hee Young;Shin, Key-Il
    • The Korean Journal of Applied Statistics
    • /
    • v.33 no.1
    • /
    • pp.11-23
    • /
    • 2020
  • Sampling design should provide statistics to meet a given accuracy while saving cost and time. However, a large number of non-responses are occurring due to the deterioration of survey circumstances, which significantly reduces the accuracy of the survey results. Non-responses occur for a variety of reasons. Chung and Shin (2017, 2019) and Min and Shin (2018) found that the accuracy of estimation is improved by removing the bias caused by non-response when the response rate is an exponential or linear function of variable of interests. For that case they assumed that the error of the super population model follows normal distribution. In this study, we proposed a non-response bias adjusted estimator in the case where the error of a super population model follows the gamma distribution or the log-normal distribution in a business survey. We confirmed the superiority of the proposed estimator through simulation studies.