Low Carbonization Technology & Traceability for Sustainable Textile Materials (지속가능 섬유 소재 추적성과 저탄소화 공정)

  • Min-ki Choi;Won-jun Kim;Myoung-hee Shim
    • Fashion & Textile Research Journal
    • /
    • v.25 no.6
    • /
    • pp.673-689
    • /
    • 2023
  • To realize the traceability of sustainable textile products, this study presents a low-carbon process through energy savings in the textile material manufacturing process. Traceability is becoming an important element of Life Cycle Assessment (LCA), which confirms the eco-friendliness of textile products as well as supply chain information. Textile products with complex manufacturing processes require traceability of each step of the process to calculate carbon emissions and power usage. Additionally, an understanding of the characteristics of the product planning-manufacturing-distribution process and an overall understanding of carbon emissions sources are required. Energy use in the textile material manufacturing stage produces the largest amount of carbon dioxide, and the amount of carbon emitted from processes such as dyeing, weaving and knitting can be calculated. Energy saving methods include efficiency improvement and energy recycling, and carbon dioxide emissions can be reduced through waste heat recovery, sensor-based smart systems, and replacement of old facilities. In the dyeing process, which uses a considerable amount of heat energy, LNG, steam can be saved by using "heat exchangers," "condensate management traps," and "tenter exhaust fan controllers." In weaving and knitting processes, which use a considerable amount of electrical energy, about 10- 20% of energy can be saved by using old compressors and motors.

Study on the Establishment of Barley Cultivation System using the Power Tiller (동력경운기를 중심으로한 맥류재배의 기계화 -관작업체계 확립에 관한 연구)

  • 이영렬;최규홍
    • Journal of Biosystems Engineering
    • /
    • v.3 no.2
    • /
    • pp.22-33
    • /
    • 1978
  • To maintain the self-sufficiency of food production , it is required to improved the productivity and increase the effective utilization of land in the double cropping areas using improved cultivation technology. The following reasons encourage this cours of action because the overlapping rice harvest and barely seeding seasons complete for labour, the lower price of barley makes it financially less attractive to grow and these two facts together are responsible for a decrease in barley being planted in certain more seasonably marginal double cropping areas. Fro these reasons, it is desirable to carry out tests to improve the current cultivation techniques . In this interest , the following studies were carried out in the experimental field located at Banweol-myeon, Whasung-jkun, Gyeonggi-do from October 1977 to July 1978 in order to establish the mechanical method of barley cultivation using the power tiller. The summarized results are as follows. 1. The work performance in the seeding operation using the rotary barley seeder was 68 minutes per 10 ares which compares favourably with 408 min/10a using the conventional method. This is only one sixth of the time required by th conventional method. The operating costs using the rotary barley seeder was 1, 463 won per 10 areas as against 3, 486 Won per 10 ares for the conventional method, showing a saving of about 50% in comparison with the conventional method. 2. In the manure spreading operation, the work performance was 25 min/10a for the manure spreading machine , compared to 1089 min/10a for the manual operations. This is about one fourth of the time required by the conventional method, The operating costs were 810 Won/10a for the machine and 857 Won/10a for the manual labour. This cost shows little advantage by the machine over the manual labor costs. The conventional method of manure spreading will continue pending decision which will develope and improve the machine.3. Work performance in the rolling operation using the barley rolIer was 30 min/lOa which compares favourably with 135 min/10a using conventional method. This was one fourth of the time required by the conventional method. The operating costs were 514 Won/103. for the machine and 1, 003 Won/lOa for manual labour. In the weed control operation, the work performance and operating costs were 45min/lOa, 1, 399won/10a for the herbcide application using the power sprayer, 1, 149min/10a 8, 541won/lOa for the conventional method respectively. This is 26 times higher efficiency in comparison to the conventional method. 4. In the harvesting operation using the reaper binder and tiller attachment, the work performance was 60min/lOa and represents a cost of 2, 039won/10a. The con\ulcornerventional method took 640min/10a at a cost of 4, 757won/lOa. The reaper binder showns a saving of one tenth over the conventional method. The automatic thresher is already recommended for the current situations, and is now being used. 5. From a comparison of the results of the above trials, the serial cultivation system using the attachment for the power tiller such as the rotary barley seeder is now to be recommended for the current barley cultivation system. It is also recommend from these results that the mechanized technology now available must be used to improve and maintain the increase in barley production. It is seen th1t this is the only course now avaihble to solve the peak seasonal requirements of labour needed for l11rvesting and seeding between rice and barley cultivation.

  • PDF

A Study of Zhuxi's Daoxuezhengzhi(道學政治) through his political frustration in the partisan struggle of 1196 Qingyuandanghuo(慶元黨禍) (1196년 경원당화(慶元黨禍)의 사상정국에서 주희의 정치적 좌절을 통해서 본 주희의 도학정치고찰)

  • Lee, Wook-Keun
    • (The)Study of the Eastern Classic
    • /
    • no.37
    • /
    • pp.473-507
    • /
    • 2009
  • The purpose of this study is to understand Zhuxi's Taoxuezhengzhi(道學政治) by reorganizing both his political opinion in each different political situation and his consistent political consciousness appeared in his whole political career. He concluded that the politics was the real problematic in Southern Sung, which made its structure distorted. This distorted structure of politics had widely rooted in whole sphere of society. In order to cure this political problematic, Zhuxi had focused on huangdi(皇帝) and chaoting(朝廷). That is why people is the basis of State and the result of politics, while huangdi and chaoting is the basis of politics and the beginnig of politics. According to Zhuxi, forming their political power group of their own will by using huangdi's power, the political elites close to only to huangdi made the function of chaoting unstable, with the result that the political decay produced. In chaoting, it resulted in the weakness of huangdi's power, the collapse of official discipline(紀綱), and the absence of public opinion(公論) and public aggreement(公議). Beyond chaoting, it resulted in the absence of political trust and the degeneration of public morals(風俗). In the Southern Sung were not altered the political orientation and culture based on the political decay, but only political orientation and characteristics of political elite only altered. This proves Zhuxi's approach that all problems in Southern Sung could resolve by the political approach. Zhuxi had suggested political issues in office. The alternatives for those political issues had basis of the theme, the one that saving people(恤民) is the purpose of politics. However his political ideas and the execution of them had been occsionally collapsed by the complex political structue, the mechanisms of political power, and the sameness and privatization of political geography in Southern Sung. Qingyuandanghuo(慶元黨禍) was the final stage of his political frustration, with the result that it led to the failure of Zhuxi's taoxuezhengzhi and interrupted the tradition of taoxue(道學) for the time being.

Improvement of Energy Density in Supercapacitor by Ion Doping Control for Energy Storage System (에너지 저장장치용 슈퍼커패시터 이온 도핑 제어를 통한 에너지 밀도 향상 연구)

  • Park, Byung-jun;Yoo, SeonMi;Yang, SeongEun;Han, SangChul;No, TaeMoo;Lee, Young Hee;Han, YoungHee
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.209-213
    • /
    • 2019
  • Recently, demand for high energy density and long cycling stability of energy storage system has increased for application using with frequency regulation (F/R) in power grid. Supercapacitor have long lifetime and high charge and discharge rate, it is very adaptable to apply a frequency regulation in power grid. Supercapacitor can complement batteries to reduce the size and installation of batteries. Because their utilization in a system can potentially eliminate the need for short-term frequent replacement as required by batteries, hence, saving the resources invested in the upkeep of the whole system or extension of lifecycle of batteries in the long run of power grid. However, low energy density in supercapacitor is critical weakness to utilization for huge energy storage system of power grid. So, it is still far from being able to replace batteries and struggle in meeting the demand for a high energy density. But, today, LIC (Lithium Ion Capacitor) considered as an attractive structure to improve energy density much more than EDLC (Electric double layer capacitor) because LIC has high voltage range up to 3.8 V. But, many aspects of the electrochemical performance of LIC still need to be examined closely in order to apply for commercial use. In this study, in order to improve the capacitance of LIC related with energy density, we designed new method of pre-doping in anode electrode. The electrode in cathode were fabricated in dry room which has a relative humidity under 0.1% and constant electrode thickness over $100{\mu}m$ was manufactured for stable mechanical strength and anode doping. To minimize of contact resistance, fabricated electrode was conducted hot compression process from room temperature to $65^{\circ}C$. We designed various pre-doping method for LIC structure and analyzing the doping mechanism issues. Finally, we suggest new pre-doping method to improve the capacitance and electrochemical stability for LIC.

A Study on T5 28W Fluorescent Lamp Ballast Using a Piezoelectric Transformer and One-chip Microcontroller (One Chip Microcontroller와 압전변압기를 이용한 T5 28W 형광등용 전자식 안정기에 관한 연구)

  • 황락훈;류주현;장은성;조문택;안익수;홍재일
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.70-79
    • /
    • 2003
  • In this paper, T5 28-watt fluorescent lamp ballast using a piezoelectric transformer is fabricated and its characteristic is investigated. Developed electronic ballast is composed of basic circuits and blocks, such as rectifier part, active power factor corrector part, frequency oscillation part using microcontroller and feedback control, piezoelectric transformer and resonant half bridge inverters. The fabricated ballast uses to variable frequency methode in external so exciting that the frequency of piezoelectric transformer could be generated by voltage control oscillator using microcontroller(AT90S4433). The current of fluorescent lamp is detected by feedback control circuit. The signal of inverter output is received using Piezoelectric transformer, and then its output transmitted to fluorescent lamp. Traditional electromagnetic ballasts operated at 50-60Hz have been suffered from noticeable flicker, high loss, large crest factor and heavy weight. A new electronic ballast is operated at high frequency about 75kHz, and then Input power factor, distortion of total harmonic and lamp current crest factor are measured about 0.9!35, 12H and 1.5, respectively Accordingly, the traditional ballast is by fabricated electronic ballast using piezoelectric transformer and voltage control oscillator because of its lighter weight, high efficiency, economic merit and saving energy.

A Study on Smart Energy Management System using Information and Communication Technology (ICT를 활용한 스마트에너지관리시스템에 관한 연구)

  • Lee, Yong-Soo;Heo, Jun;Choi, Yong-Hoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.167-172
    • /
    • 2014
  • Recently interest in energy is becoming increasingly amplified in the world. Green energy is the buzzword of the world's business community as well as governments also leave a green energy seonbongjang of economic recovery. According to the International Institute for Energy, it will be expected to invest in the field of green energy about 7 trillion dollar traslated into 7,000 trillian won around the world by 2030. Thus production, supply, reduce and reuse policies and techniques for green energy came pouring out like a flood. But there is a limit to the fuel supply in order to produce a power generation facility and the power supply that is essential. Reducing produced power efficiently is more important than the increasing of power production. At present, using a method that controls the equipment installed by measuring the environment for efficient control of the energy management of energy-consuming devices that are in use. But the reality is that many policies of national and corporate to did not work to solve a part of the energy savings. In this paper, I proposes a smart energy management system to control the equipment by using the accumulated data obtained with minimal changes in the environment using the energy.

Realization of an IEEE 802.11g VoWLAN Terminal with Support of Adaptable Power Save and QoS During a Call (통화 중 적응적 Power Save와 QoS 지원이 가능한 IEEE B02.11g VoWLAN 단말기 구현)

  • Kwon, Sung-Su;Lee, Jong-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.10A
    • /
    • pp.1003-1013
    • /
    • 2006
  • There is a serious problem in an 802.11g VoWLAN (Voice over Wireless LAN) terminal that talk time is less than 30% compared with an 802.11b terminal. It is almost impossible to achieve talk time level of the 802.11b MAC transmission method because IEEE 802.11g uses OFDM modulation, which is a kind of multi-carrier method and OFDM transmission speed is 54 Mbps faster than normal modulation. In this paper, a new concept of a Holdover time as a power saving method during a call with 802.11g terminal is suggested for the first time. Increase in the number of engaged terminals as a result of holdover time causes to QoS problem because of the increase in the number of back-off and then contention window. In this paper, to solve the QoS problem, a new approach is suggested such that when in down lint the sequence number of 802.11 G.711 is analyzed in the MAC of the terminal and then the Hold over time depending on loss rate is changed. Also, consumption of an electric current of 802.11b/g and MAC parameter's performance due to busy traffic caused by increase in the number of terminal are analyzed and then real data using VQT and Airopeek are analyzed.

Prediction of Performance Characteristics with Various Location of Waste Heat Recovery Heat Pump in a Gwang-gyo Cogeneration Plant (냉각수 활용 히트펌프 설치 위치에 따른 광교 열병합발전소의 성능 특성 예측)

  • Park, Heun-Dong;Heo, Ki-Moo;Yoon, Sung-Hoon;Moon, Yoon-Jae;Yoo, Ho-Sun;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.10 no.2
    • /
    • pp.28-37
    • /
    • 2014
  • Recently, it is considered that environment and energy are critical issues all over the world. In power generation sector in Korea, almost power stations are constructed and operated as cogeneration plants in conformity with this trend. KDHC(Korea District Heating Corporation) goes one step further adopting renewable energy technology like heat pump using wasted heat for energy-saving and environment improvement. This study investigates the performance characteristics by the location of waste heat recovery heat pumps of 5 Gcal/h capacity in 150 MW-class Gwang-gyo cogeneration plant using commercial software 'THERMOFLEX'. Prior to analysis, the simulations are performed with actual operation data, and then the validation of simulations is verified by checking the error within 2%. After verification, the simulations are carried out with 3 locations and the effect on electrical power output and heat output is analyzed. As a result, overall efficiency of cogeneration plant is the highest in the case of heat pump located before DH(District Heating) Heater because of the largest increase of heat output despite of decrease of electrical power output.

  • PDF

Particle Swarm Optimization-Based Peak Shaving Scheme Using ESS for Reducing Electricity Tariff (전기요금 절감용 ESS를 활용한 Particle Swarm Optimization 기반 Peak Shaving 제어 방법)

  • Park, Myoung Woo;Kang, Moses;Yun, YongWoon;Hong, Seonri;BAE, KUK YEOL;Baek, Jongbok
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.388-398
    • /
    • 2021
  • This paper proposes a particle swarm optimization (PSO)-based peak shaving scheme using energy storage system (ESS) for electricity tariff reduction. The proposed scheme compares the actual load with the estimated load consumption, calculates the additional output power that the ESS needs to discharge additionally to reduce peak load, and adds the input. In addition, in order to compensate for the additional power, the process of allocating power to the determined point is performed, and an optimization that minimizes the average of the load expected at the active power allocations using PSO so that the allocated value does not affect the peak load. To investigated the performance of the proposed scheme, case study of small and large load prediction errors was conducted by reflecting actual load data and load prediction algorithm. As a result, when the proposed scheme is performed with the ESS charge and discharge control to reduce electricity tariff, even when the load prediction error is large, the peak load is successfully reduced, and the peak load reduction effect of 17.8% and electricity tariff reduction effect of 6.02% is shown.

A Study on Performance Evaluation of Light Shelf according to the Reflectivity of Interior Space (실내 공간의 반사율에 따른 광선반 성능평가 연구)

  • Jeon, Gangmin;Lee, Heangwoo;Kim, Yongseong
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.5 no.5
    • /
    • pp.461-470
    • /
    • 2015
  • There has been a significant increase in the amount of research on reducing the lighting power consumption of buildings and also an increasing demand for technological development. Light shelf has been recognized as one of the most efficient solutions to this issue and related researches have been conducted, which have mostly focused on factors related to simple light shelves and are not suitable as an appropriate basis for the design of light shelves. Thus this study aims to establish the proper design basis for light shelves by evaluating the performance of shelves per reflection rate in indoor areas. Power consumption rate and indoor illumination intensity distribution of a testbed built based on actual living conditions were calculated for the performance evaluation, of which the results are as following: 1) Reduction of reflection rate of ceiling and walls caused average illumination intensity in summer, winter and median seasons, and evenness per reflection rate of indoor areas was found to be different in summer, winter and median seasons, making it a necessary consideration for designing light shelves. 2) Calculation of power consumption from lighting control showed that a high reflection rate of indoor areas may be suitable for power consumption reduction, and that reflection rates higher than 80% for ceilings and higher than 75% for walls in terms of the efficiency of researches on the indoor reflection rate and its application would be appropriate. This study is meaningful as the research focuses on light shelves based on considering indoor environmental factors. More studies will be required that consider a variety of factors.