• Title/Summary/Keyword: Power network

Search Result 5,967, Processing Time 0.03 seconds

Design of ATM Networks to transfer for Electric Power System Informations (전력정보 전달을 위한 ATM 망 설계)

  • Jeong, Young-Kyeung;Kim, Han-Kyeung
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.572-574
    • /
    • 1998
  • In this paper, we are proposed design of ATM networks to transfer for electric power system informations, proposed transport networks is partitioned management part and functional part, management part is partitioned edge network, core network, local network, authority network, functional part is partitioned core network, access network, edge area. It is based on laying and partitioning by ITU-T G.805, we also proposed ATM network requirements for Carrier Relay traffic acceptability in electric power system information.

  • PDF

Mutual Authentication Protocol Using a Low Power in the Ubiquitous Computing Environment

  • Cho Young-bok;Kim Dong-myung;Lee Sang-ho
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.91-94
    • /
    • 2004
  • Ubiquitous sensor network is to manage and collect information autonomously by communicating user around device. Security requirements in Ubiquitous based on sensor network are as follows: a location of sensor, a restriction of performance by low electric power, communication by broadcasting, etc. We propose new mutual authentication protocol using a low power of sensor node. This protocol solved a low power problem by reducing calculation overload of sensor node using two steps, RM(Register Manager) and AM(Authentication Manager). Many operations performing the sensor node itself have a big overload in low power node. Our protocol reduces the operation number from sensor node. Also it is mutual authentication protocol in Ubiquitous network, which satisfies mutual authentication, session key establishment, user and device authentication, MITM attack, confidentiality, integrity, and is safe the security enemy with solving low electric power problem.

  • PDF

A Routing Scheme for Reducing the Power Consumption of USN Nodes (USN 노드의 소비전력 절감을 위한 경로설정 기법)

  • Lee, Moon-Ho
    • Journal of Information Technology Applications and Management
    • /
    • v.14 no.2
    • /
    • pp.1-10
    • /
    • 2007
  • The ubiquitous computing system is expected to be widely utilized in digital home, logistics control, environment/disaster management, medical/health-care services and other applications. The ubiquitous sensor network (USN) is a key infra-structure of this system. Nodes in the USN are exposed to adverse environments and required to perform their missions with very limited power supply only. Also the sensor network is composed of much more nodes. In case some node consumes up its power capacity under a certain required level, the network topology should change and re-routing/ re-transmission of data is necessitated. Resultantly communication protocols studied for conventional wireless networks or ad-hoc networks are not suitable for the sensor network. Schemes should be devised to control the efficient usage of node power in the sensor network. This paper proposes a routing algorithm to enhance the efficiency of power consumption for USN node and analyzes its performance by simulation.

  • PDF

Influence of the Interconnected Wind farm on Protection for Distribution Networks (풍력발전단지의 계통연계 운전이 배전선 보호계전에 미치는 영향)

  • 장성일;김광호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.3
    • /
    • pp.151-157
    • /
    • 2003
  • Wind farm interconnected with grid can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the distribution power line with wind fm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator due to the contribution of wind farm. Consequently, it may be difficult to detect the fault happened in the distribution network connected with wind generator This paper describes the effect of the interconnected wind turbine generators on protective relaying of distribution power lines and detection of the fault occurred in a power line network. Simulation results shows that the current level of fault happened in the power line with wind farm depends on the fault impedance, the fault location. the output of wind farm. and the load condition of distribution network.

Design of a Reliable Network for DCS in Nuclear Power Plant (원자력 발전소 분산 제어 시스템을 위한 고신뢰 통신망의 설계)

  • Lee, Sung-Woo;Im, Han-Suck
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.588-590
    • /
    • 1997
  • In this paper, a highly reliable communication network for DCS in nuclear power plant is designed. The structure and characteristics of DCS in nuclear power plant is briefly explained. The features needed for a communication network for DCS in nuclear power plant is described. According to the abovo features, the layer structure of the communication network is determined and each layer is designed in detail.

  • PDF

A Connectionist Expert System for Fault Diagnosis of Power System (전력계통 사고구간 판정을 위한 Commectionist Expert System)

  • 김광호;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.4
    • /
    • pp.331-338
    • /
    • 1992
  • The application of Connectionist expert system using neural network to fault diagnosis of power system is presented and compared with rule-based expert system. Also, the merits of Connectionist model using neural network is presented. In this paper, the neural network for fault diagnosis is hierarchically composed by 3 neural network classes. The whole power system is divided into subsystems, the neural networks (Class II) which take charge of each subsystem and the neural network (Class III) which connects subsystems are composed. Every section of power system is classified into one of the typical sections which can be applied with same diagnosis rules, as line-section, bus-section, transformer-section. For each typical section, only one neural network (Class I) is composed. As the proposed model has hierarchical structure, the great reduction of learning structure is achieved. With parallel distributed processing, we show the possibility of on-line fault diagnosis.

  • PDF

Artificial neural network reconstructs core power distribution

  • Li, Wenhuai;Ding, Peng;Xia, Wenqing;Chen, Shu;Yu, Fengwan;Duan, Chengjie;Cui, Dawei;Chen, Chen
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.617-626
    • /
    • 2022
  • To effectively monitor the variety of distributions of neutron flux, fuel power or temperatures in the reactor core, usually the ex-core and in-core neutron detectors are employed. The thermocouples for temperature measurement are installed in the coolant inlet or outlet of the respective fuel assemblies. It is necessary to reconstruct the measurement information of the whole reactor position. However, the reading of different types of detector in the core reflects different aspects of the 3D power distribution. The feasibility of reconstruction the core three-dimension power distribution by using different combinations of in-core, ex-core and thermocouples detectors is analyzed in this paper to synthesize the useful information of various detectors. A comparison of multilayer perceptron (MLP) network and radial basis function (RBF) network is performed. RBF results are more extreme precision but also more sensitivity to detector failure and uncertainty, compare to MLP networks. This is because that localized neural network could offer conservative regression in RBF. Adding random disturbance in training dataset is helpful to reduce the influence of detector failure and uncertainty. Some convolution neural networks seem to be helpful to get more accurate results by use more spatial layout information, though relative researches are still under way.

Development of Low Power PLC Modem for Monitoring of Power Consumption and Breaking of Abnormal Power (전력감시 및 이상전력 차단 기능을 갖는 저전력 전력선통신 모뎀 개발)

  • Yoon, Jae-Shik;Wee, Jung-Chul;Park, Chung-Ha;Song, Yong-Jae;Kim, Jae-Heon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2281-2285
    • /
    • 2009
  • Powerline communication is the data signal which is modulated by carrier frequency through the installed powerline at in-home or office is transmitted and received signals are separated into data signal with using band-pass filter which cent-frequency is carrier frequency. The home gateway, an equipment which works as an gateway for ubiquitous home network, relays all functions of a home network. The home gateway must always be connected in order to provide seamless services. However it gives unfavorable power consumption. Therefore the needs for working in maximum power saving mode while there is no data traffic and for invoking to the normal function when it is necessary. So, in this paper we survey the development of low power PLC modem monitoring of power consumption and breaking abnormal power in the home Network.

An Autonomous Optimal Coordination Scheme in a Protection System of a Power Distribution Network by using a Multi-Agent Concept

  • Hyun, Seung-Ho;Min, Byung-Woon;Jung, Kwang-Ho;Lee, Seung-Jae;Park, Myeon-Song;Kang, Sang-Hee
    • KIEE International Transactions on Power Engineering
    • /
    • v.2A no.3
    • /
    • pp.89-94
    • /
    • 2002
  • In this paper, a protection system using a Multi-Agent concept for power distribution networks is proposed. Every digital over current relay(OCR) is developed as an agent by adding its own intelligence, self-tuning and communication ability. The main advantage of the Multi-Agent concept is that a group of agents work together to achieve a global goal which is beyond the ability of each individual agent. In order to cope with frequent changes in the network operation condition and faults, an OCR agent, suggested in this paper, is able to detect a fault or a change in the network and find its optimal parameters for protection in an autonomous manner considering information of the whole network obtained by communication between other agents. Through this kind of coordination and information exchanges, not only a local but also a global protective scheme is completed. Simulations in a simple distribution network show the effectiveness of the suggested protection system.

Introduction of Power Flow Tracing Method for Determination of Power Transmission Network Charge and Verification of Its Effectiveness (송전요금 결정을 위한 전력조류 추적법의 도입 및 효용성 검증)

  • No, Gyeong-Su
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.2
    • /
    • pp.53-58
    • /
    • 2002
  • This paper describes methodologies to charge for power transmission network use. These methodologies are normally divided into two categories such as marginal cost method and embedded cost allocation method. This paper, first, discusses the possible problems that can occur when the marginal cost method is applied to pricing the transmission services. Next, the paper proposes a method to apply the electricity tracing method to the transmission network charge. The result of the electricity tracing method is then used in MW-mile method to charge individual loads for the use of transmission network. Effectiveness of the algorithm is verified by computer simulations and it is estimated that the results can be used to compute the cost of electric power transmission under deregulated environment in electric power industries.