• Title/Summary/Keyword: Power meter

Search Result 527, Processing Time 0.026 seconds

The Effect of Low Temperature Plasma Treatment Condition on the Peel Strength of EVA Foam for Shoe Mid-sole (저온플라즈마 처리조건이 신발 중창용 EVA 발포체의 접착력에 미치는 영향)

  • Park, C.C.;Park, C.Y.
    • Elastomers and Composites
    • /
    • v.35 no.4
    • /
    • pp.296-302
    • /
    • 2000
  • The surfaces of injection and pressure-molded sheets of poly(ethylene-covulylacetate)(EVA) foams used for shoe mid-sole were treated with low temperature plasma to improve adhesion with a water-based polyurethane adhesives. Several experimental variables were considered, such as radio frequency power, treating time, type of gas. gas flow, and distance between electrode and sample. The modificated surface by plasma treatment were characterized using contact angle meter, scanning electron microscopy(SEM), universal testing machine(UTM). Adhesion was tested by T-peel tests of treated EVA foams/polyurethane adhesive joints. The treatment in the low temperature plasma produced a noticeable decrease in contact angle. The peel strength of EVA foams treated with plasma was increased with plasma treating time, and gas flow.

  • PDF

A Study on the Characteristics of Mass Transfer in Hollow Fiber Membranes (중공사막에서의 물질전달 특성에 관한 연구)

  • 김기범;김종석;김종수;유일수;이왕로;김성종
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.142-148
    • /
    • 2004
  • This paper presents the enhancement of oxygen transfer efficiency using vibrating intravascular lung assist device (VIVLAD) for patients having chronic respiratory problems. The flow rate was controlled by the pump and monitored by a built-in flow meter. The vibration apparatus was composed of a piezo-actuator, a function generator, and a power amplifier. Gas flow rates of up to 6 L/min through the 120-cm-long hollow fibers have been achieved by exciting a piezo-actuator. The output PVDF sensor and FRF (frequency response function) were investigated by various frequency in VIVLAD. As a result, the maximum oxygen transfer rate was found to occur with maximum amplitude and the transfer of vibration to the hollow fiber membranes. It was excited by the frequency band of 35 Hz at various distilled water flow rates, and various module types.

Analysis of Natural Frequency According to Span of Foot-bridges (보도교의 구조시스템별 고유진동수 분석)

  • Do, Ki Young;Yoon, Sung Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.5
    • /
    • pp.375-383
    • /
    • 2014
  • In Seoul, total 166 places of foot-bridges were constructed but a study on correlation between resonance occurrence status by gait vibration and natural frequency by each span and that between span based on structural system and natural frequency is very unsatisfactory in reality. Consequently in this study, time series wave form, power spectrum and natural frequency were analyzed based on resonance occurrence by targeting 65 places of foot-bridges being constructed in Seoul through convenient and simple portable vibration meter.

Development of Automated Surface Inspection System using the Computer V (컴퓨터 비젼을 이용한 표면결함검사장치 개발)

  • Lee, Jong-Hak;Jung, Jin-Yang
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.668-670
    • /
    • 1999
  • We have developed a automatic surface inspection system for cold Rolled strips in steel making process for several years. We have experienced the various kinds of surface inspection systems, including linear CCD camera type and the laser type inspection system which was installed in cold rolled strips production lines. But, we did not satisfied with these inspection systems owing to insufficient detection and classification rate, real time processing performance and limited line speed of real production lines. In order to increase detection and computing power, we have used the Dark Field illumination with Infra_Red LED, Bright Field illumination with Xenon Lamp, Parallel Computing Processor with Area typed CCD camera and full software based image processing technique for the ease up_grading and maintenance. In this paper, we introduced the automatic inspection system and real time image processing technique using the Object Detection, Defect Detection, Classification algorithms. As a result of experiment, under the situation of the high speed processed line(max 1000 meter per minute) defect detection is above 90% for all occurred defects in real line, defect name classification rate is about 80% for most frequently occurred 8 defect, and defect grade classification rate is 84% for name classified defect.

  • PDF

Temperature Dependence of Volume Resistivity Characteristics for Nano Composit Epoxy (나노컴퍼지트 에폭시 체적고유저항의 온도의존성)

  • Lee, Dong-Gun;Back, Sung-Hak;Park, Tae-Hak;Park, Hong-Kyu;Jeong, In-Bum;Kim, Joung-Sik;Hong, Jin-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.91-91
    • /
    • 2010
  • In this paper, nano composites material is produced by adding MgO with particle size of 5 [nm] into epoxy resign using as insulating material of power transformer apparatus and molding part to study the volume resistivity of nano composites used epoxy. We measured the volume resistivity using the High Resistance Meter(4329A) depending on changing the amount of addition and temperature in this experience. In result, we have confirmed that 1.0, 3.0, 5.0 and 10.0 [wt%] as about 2.9, 7.6, 7.5 and 6.1 times increased than virgin. Therefore, the characteristic of volume resistivity was relatively stable as specimen by added 3.0 [wt%] than the others.

  • PDF

DEVELOPMENT OF 2.8-GHZ SOLAR FLUX RECEIVERS

  • Yun, Youngjoo;Park, Yong-Sun;Kim, Chang-Hee;Lee, Bangwon;Kim, Jung-Hoon;Yoo, Saeho;Lee, Chul-Hwan;Han, Jinwook;Kim, Young Yun
    • Journal of The Korean Astronomical Society
    • /
    • v.47 no.6
    • /
    • pp.201-207
    • /
    • 2014
  • We report the development of solar flux receivers operating at 2.8 GHz to monitor solar radio activity. Radio waves from the sun are amplified, filtered, and then transmitted to a power meter sensor without frequency down-conversion. To measure solar flux, a calibration scheme is designed with a noise source, an ambient load, and a hot load at $100^{\circ}C$. The receiver is attached to a 1.8 m parabolic antenna in Icheon, owned by National Radio Research Agency, and observation is being conducted during day time on a daily basis. We compare the solar fluxes measured for last seven months with solar fluxes obtained by DRAO in Penticton, Canada, and by the Hiraiso solar observatory in Japan, and finally establish equations to convert observed flux to the so-called Penticton flux with an accuracy better than 3.2 sfu.

Development of a Test Rig for Three-Dimensional Axial-Type Turbine Blade (축류형 3차원 터빈익형의 성능시험장치 개발)

  • Chang, B.I.;Kim, D.S.;Cho, S.Y.;Kim, S.Y.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.453-460
    • /
    • 2000
  • A test rig is developed for performance test of 1 stage axial-type turbine which is designed by meanline analysis, streamline curvature method, and blade design method using configuration parameters. The purpose of this study is to find the best configuration parameters for designing a high efficiency axial-type turbine blade. To measure the efficiency of turbine stage, a dynamo-meter is installed. Two different stators which are manufactured as an integrated type are developed, and a rotor blade and 5 sets disc are developed for setting different stagger angle. The tip and hub diameters of the test turbine are 300 and 206.4mm, respectively. The rotating speed is 1800RPM, and the extracted power is 2.5kW. Flow coefficient is 1.68 and the reaction factor at meanline is 0.373. The number of stator and rotor of test turbine are 31 and 41, respectively. The Mach number of stator exit flow near hub is 0.164.

  • PDF

DLMS SCADA System based on TETRA (TETRA 기반 DLMS 원방감시 시스템)

  • Song, Byung-Kwen;Lee, Suk-Hee
    • Journal of IKEEE
    • /
    • v.13 no.3
    • /
    • pp.95-102
    • /
    • 2009
  • TETRA(TErrestrial Trunked RAdio) is wireless communication system generally adopted to public network and backbone network, as the technology of Trunked Radio System specified by ETSI(European Telecommunications Standards Institute) and currently adopted to the Electric Power IT Backbone Network in Korea. DLMS(Device Language Message Specification) is used in order to meter an electric measuring instrument value. In this paper, DLMS Server and Client simulator are used based on Window operating system. The multi-functional gateway, which transforms the communications based on RS-232C between DLMS Server Simulator and Client Simulator to the one based on TETRA PEI(Peripheral Equipment Interface), is developed such that DLMS SCADA(Supervisory Control And Data Acquisition) system is constructed based on TETRA.

  • PDF

The Volume Resistivity properties due to the Curing Condition of Silicone Gel for Power Semiconductor (실리콘 젤의 경화조건에 따른 체적고유저항 특성)

  • Song, Byung-Gi;Cho, Kyung-Soon;Shin, Jong-Yeol;Kim, Lee-Doo;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.270-272
    • /
    • 1997
  • In order to a study on the electrical properties of silicone gel due to the curing condition, the volume resistivity test is researched. For experiment, we have made up several samples of different curing temperature and time such as 1[H], 2[H] at 125[$^{\circ}C$], 150[$^{\circ}C$], 160[$^{\circ}C$], 170[$^{\circ}C$], 180[$^{\circ}C$]. A measurement of volume resistivity using the VMG-1000 highmegohm meter is recorded after 10 minutes when the each voltage, and DC 500[V] and 1000[V] is applied. A coaxial cylindrical liquid electrode to measure volume resistivity of specimen is used, and its geometric capacitance is 2[pF]. As a result of the experiment, the electrical properties of specimen cured at 170[$^{\circ}C$] for 2[H] is superior.

  • PDF

A Study of an Efficient ZigBee Address Assignment Scheme for Home Area Networks of Smart Grid

  • Choi, Dongmin;Chung, Ilyong
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.5
    • /
    • pp.566-576
    • /
    • 2013
  • In Home Area Network (HAN) of the smart grid, Power Line Communication (PLC) technology and ZigBee communication technology can be used in the communication among the Advanced Metering Infrastructure (AMI) devices. However, according to performance evaluation results of the PLC technology, we find that using the PLC technology is unsuitable for the remote meter reading service. It is worth noting that some parts of the PLC are converted to the ZigBee communication technology in Jeju, Korea. Compared with PLC, ZigBee has no restriction of the place, where the equipments can be freely set up, due to the advantage of radio communication. However, number of usable devices will impact the network performance which is depended on the address assignment. In addition, due to the restriction of transmission range among devices, it is difficult to apply the ZigBee address assignment method to the practical circumstance. In this paper, we examine the previous ZigBee address assignment schemes and the corresponding routing algorithms, and propose a novel address assignment scheme compared with the existing methods, the performance of the proposed one is improved. In particular, evaluation results show that the proposed scheme reduces the average number of hop count, the transfer time and the processing time.