• 제목/요약/키워드: Power measurements

검색결과 1,590건 처리시간 0.032초

큰 회전각을 가지는 터빈 블레이드 표면에서 나프탈렌승화법을 이용한 열(물질)전달계수 측정 (Measurements of Heat (Mass) Transfer Coefficient on the Surface of a Turbine Blade with n High Turning Angle Using Naphthalene Sublimation Technique)

  • 권현구;이상우;박병규
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1077-1087
    • /
    • 2002
  • The heat (mass) transfer characteristics on the blade surface of a high-turning first-stage turbine rotor for power generation has been investigated by employing the naphthalene sublimation technique. A four-axis profile measurement system is developed successfully for the measurements of local sublimation depth on the curved surface In the leading edge region, there is a good agreement between the present heat (mass) transfer data and the previous result on a turbine blade with a moderate turning angle, but some discrepancies are found in the mid-chord heat (mass) transfer between the two results. The local heat (mass) transfer on the present suction surface is greatly enhanced due to an earlier boundary transition, compared with that on a turbine blade with a moderate turning angle, meanwhile there is only a slight change in the pressure-side heat (mass) transfer between the two different turbine rotors. In general, the heat (mass) transfer augmentation by the endwall vortices is found much higher on the suction surface than on the pressure surface.

Partial Discharge Measurements of Artificial Defects in HTS Transformer Model using HFCT

  • Lee, S.H.;Shin, W.J.;Park, T.G.;Koo, J.Y.;Lee, B.W.
    • Progress in Superconductivity
    • /
    • 제11권1호
    • /
    • pp.13-18
    • /
    • 2009
  • Partial discharge measurements in cryogenic dielectric materials of HTS transformer are very important because partial discharge was regarded as primary source for ageing and breakdown of cryogenic materials. But, partial discharge measurement techniques and its effects in low temperature high voltage environments were not suggested and there exist only a few reports on this research fields. Therefore, in order to implement reliable HTS transformers, partial discharge diagnosis techniques for cryogenic materials of HTS transformers were investigated using partial discharge (PD) pattern analysis methods. In this works, four different types of artificial defects including turn to turn insulation, free moving particle, void and protrusion, have been fabricated since it was commonly regarded that they might cause the sudden service failures of the power apparatus. For this purpose, these defects are installed into the dielectric materials in liquid nitrogen and experimental investigations have been carried out for the diagnosis of HTS transformer. And various PD patterns caused by the amount of quench of superconductors were analyzed. Throughout this works, the different PD patterns in cryogenic dielectric materials in liquid nitrogen, and PD measuring technique could be the fundamental steps to establish diagnosis technologies of HTS transformer for power applications.

  • PDF

Sensorless Control of a Single-Phase Switched Reluctance Motor Using Residual Flux

  • Yang, Hyong-Yeol;Shin, Duck-Shick;Lim, Young-Cheol
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.911-918
    • /
    • 2009
  • This paper presents a new sensorless control method for single-phase switched reluctance motors using induced electromotive force (EMF) due to the residual flux both on the stator and the rotor during phase commutation. The induced EMF falls to zero when the rotor pole moves away from the overlap with the stator pole. By detecting this instant, the speed and position of the rotor can be simply estimated. This method is very simple to implement and it is insensitive to variations in the system parameters as it does not require any stored magnetic data or offline inductance measurements but requires only measurements of the terminal voltage and a simple analog circuit. The proposed method is implemented on a 6/6 single-phase switched reluctance motor. However, it can also be implemented on a multiphase SRM regardless of the size, operation speed and switching mode of the motor hence making the proposed method viable to many applications. Simulation and experimental verification is provided to demonstrate the feasibility of the proposed method.

정적챔버에서 GDI용 연료분사기의 가솔린, M85, E85 및 LPG 분무 계측 (The Spray Measurements of Gasoline, M85, E85, and LPG by a GDI Injector in a Constant Volume Chamber)

  • 김성수
    • 동력기계공학회지
    • /
    • 제16권6호
    • /
    • pp.5-10
    • /
    • 2012
  • Spray structures and penetration lengths of Gasoline, M85, E85, and LPG by a GDI 6-hole fuel injector were examined in a constant volume chamber. The chamber pressure was controlled at 0.1 MPa and 0.9 MPa. The effects of fuel injection pressure and chamber pressure on the spray structures and penetration lengths were investigated using the 2-dimensional Mie scattering technique. It was found that the sprays developed linearly till ASOI 1.7ms after start of injection and vortices were happened around jets on the way of spray development. And the high chamber pressure, 0.9 MPa kept the fuel sprays development down and the penetration length was reduced to about 55% compared with that of 0.1 MPa. In additions high pressure of fuel injection, 12 MPa increased the spray penetration length more about 7~10% than that of 7 MPa.

CT scan의 다평면 재구성을 하는 Dentascan 프로그램과 개인용 컴퓨터를 이용한 영상재형성과의 비교에 관한 연구 (Comparison of Image reformation Using Personal Computer with Dentascan Program)

  • 김은경
    • 치과방사선
    • /
    • 제27권1호
    • /
    • pp.7-16
    • /
    • 1997
  • This study was performed to demonstrate the method of image reformation for dental implants, using a personal computer with inexpensive softwares and to compare the images reformatted using the above method with those using Dentascan software. CT axial slices of 5 mandibles of 5 volunteers from GE Highspeed Advantage(GE Medical systems, U.S.A.) were used. Personal computer used for image reformation was PowerWave 6041120 (Power Computing Co, U.S.A.) and softwares used were Osiris (Univ. Hospital of Geneva, Switzerland) and Import ACCESS V1.H Designed Access Co., U.S.A.) for importing CT images and NIH Image 1.58 (NIH, U.S.A.) for image processing. Seven images were selected among the serial reconstructed cross-sectional images produced by Dentascan(DS group). Seven resliced cross-sectional images at the same position were obtained at the personal computer(PC group). Regression analysis of the measurements of PC group was done against those of DS group. Measurements of the bone height and width at the reformed cross-sectional images using Mac-compatible computer were highly correlated with those using workstation with Dentascan software(height : r²=0.999, p<0.001, width : r²=0.991, p<0.001). So, it is considered that we can use a personal computer with inexpensive softwares for the dental implant planning, instead of the expensive software and workstation.

  • PDF

A Review on the Job Stress Measurements in Nuclear Power Plant Workers for Human Error Prevention

  • Kim, Seon Soo;Luo, Meiling;Oh, Yeon Ju;Lee, Yong Hee
    • 대한인간공학회지
    • /
    • 제32권1호
    • /
    • pp.47-58
    • /
    • 2013
  • Objective: The aim of this study is to review the job stress measurement for applying in nuclear power plants(NPPs). Background: The standard and guideline to evaluate and manage the job stress is insufficient in NPPs. Although job stress might have a negative effect on task performance particularly it can be related with human error in NPPs. Method/Results: This paper considered the objective and subjective stress measurements. One of the questionnaire(Korean Occupational Stress Scale) and the experiment method was investigated to apply in NPPs. KOSS was analyzed about the inter item consistency and correlation with the workload, and relative importance. In the objective evaluation considered the experiment method for the physical and mental job stress and analyzed from the phased point of view. Conclusion/Application: The measurement and criteria to evaluate job stress for operators must be complemented on the job characters and environments in NPPs. This study may support to confirm and manage the job stress in NPPs. The study of more specific methodology on job stress in NPPs is required on the basis of this paper.

GAMMA-SPECTROMETRY IN ENVIRONMENTAL MONITORING OF NUCLEAR POWER

  • Cechak, Tomas;Gerndt, Josef;Kluson, Jaroslav;Musilek, Ladislav;Thinova, Lenka
    • Journal of Radiation Protection and Research
    • /
    • 제26권3호
    • /
    • pp.203-206
    • /
    • 2001
  • The mathematical processing (unfolding) of pulse height spectra from a scintillation detector helps to calculate the photon fluence rate energy distribution in a measured photon field. The data processing is based on the knowledge of detection system response function and directional dependence respectively. The experimental results of the photon fields measurements in the vicinity of the spent fuel temporary storage and inside the storage hall are presented. The containers Castor 440 are used for temporary storing of the burnt up fuel assemblies in the Czech nuclear power plant Dukovany. A set of periodical measurements was performed in order to get basic information on the time dependence of the photon fields spatial distributions and spectral characteristics in the temporary storage hall and its vicinity. The photon fields were measured by the scintillation system. The obtained photon fields spatial distributions and spectral characteristics present the information on the radiation hazard in the storage.

  • PDF

Comparison of Antenna Parameters of R-/S-Band Standard Gain Horn Antennas

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Park, Jeong-Il
    • Journal of electromagnetic engineering and science
    • /
    • 제15권4호
    • /
    • pp.224-231
    • /
    • 2015
  • A comparison of the antenna parameters for R-band (1.7-2.6 GHz) and S-band (2.6-3.95 GHz) standard gain horn antennas has been performed by the Korea Research Institute of Standards and Science (KRISS), together with seven domestic participants from private companies and public institutions. Its purpose, as a proficiency test program of the 'Antenna Measurement Club' of KRISS, was to check equivalences in antenna parameter measurements between KRISS and the participants, particularly in the R-/S-band, to support antenna manufacturers and end users in Korea. The measurement parameters of this comparison are the power gain, radiation pattern, and reflection coefficient of the traveling standards for R-/S-band pyramidal standard gain horn antennas. The comparison used a gain comparison method and an extrapolation method to measure the power gain of the two traveling standards; the radiation patterns were measured in the far-field region of the transmitting and receiving antennas.

Damage detection on output-only monitoring of dynamic curvature in composite decks

  • Domaneschi, M.;Sigurdardottir, D.;Glisic, B.
    • Structural Monitoring and Maintenance
    • /
    • 제4권1호
    • /
    • pp.1-15
    • /
    • 2017
  • Installation of sensors networks for continuous in-service monitoring of structures and their efficiency conditions is a current research trend of paramount interest. On-line monitoring systems could be strategically useful for road infrastructures, which are expected to perform efficiently and be self-diagnostic, also in emergency scenarios. This work researches damage detection in composite concrete-steel structures that are typical for highway overpasses and bridges. The techniques herein proposed assume that typical damage in the deck occurs in form of delamination and cracking, and that it affects the peak power spectral density of dynamic curvature. The investigation is performed by combining results of measurements collected by long-gauge fiber optic strain sensors installed on monitored structure and a statistic approach. A finite element model has been also prepared and validated for deepening peculiar aspects of the investigation and the availability of the method. The proposed method for real time applications is able to detect a documented unusual behavior (e.g., damage or deterioration) through long-gauge fiber optic strain sensors measurements and a probabilistic study of the dynamic curvature power spectral density.

치과 임플란트 계획시 개인용 컴퓨터를 이용한 영상재형성에 관한 연구 (Image Reformation with a Personal Computer for Dental Implant Planning)

  • Eun-Kyung Kim
    • Journal of Oral Medicine and Pain
    • /
    • 제21권2호
    • /
    • pp.255-264
    • /
    • 1996
  • This study was performed to demonstrate the method of image reformation for dental implants, using a personal computer with inexpensive softwares and to compare the images reformatted using the above method with those using Dentascan software. CT axial slices of 4 mandibles of 4 volunteers from GE Highspeed Advantage(GE Medical systems, U.S.A.) were used. personal computer used for image reformation was PowerWave 604/120 (Power computing Co, U.S.A. ) and softwares used were Osiris (Univ. Hospital of Geneva, Switzerland) and ImportACLESS Vl.1 (Designed Access Co., U.S.A.) for importing CT images and NIH image 1.58 (NIH, U.S.A.) for image processing. Seven image were selected among the serial reconstructed cross-sectional images produced by Dentascan. Seven resliced cross-sectional images at the same position were obtained at the personal computer. Regression analysis of the measurements of PC group was done against those of DS group. Measurements of the bone height and width at the reformer cross-sectional images using Mac-compatible computer was highly correlated with those using workstation with Dentascan software(height : r2= 0.999, p<0.001, width : r2= 0.993, p <0.001). So, it is considered that we can use a personal computer with inexpensive software for the dental implant planning, instead of the expensive software and workstation.

  • PDF