• Title/Summary/Keyword: Power loss analysis

Search Result 1,498, Processing Time 0.027 seconds

Design of the Linked Patch Monopole Antenna and Its SAR Analysis along with Antenna Direction (연결된 패치 형태의 모노폴 안테나 설계 및 안테나 탑재 방향에 따른 SAR 분석)

  • Yang, Joo-Hun;Lee, Seungwoo;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.10
    • /
    • pp.1117-1127
    • /
    • 2012
  • In this paper, the monopole antenna for satisfying GSM900/DCS1800/PCS1900/UMTS2100 services is designed. We can get the characteristic of the low frequency bands by connecting the front patch to the back patch of the antenna and get the low frequency resonance band using a front patch slit. The proposed antenna total volume is $40{\times}98{\times}1.6\;mm^3$, and it is designed on the FR-4 substrate having a relative dielectric constant of 4.4. As measurement result after fabrication, showed that the resonant frequency bandwidths are 156 MHz(828~984 MHz), 708 MHz(1.476~2.184 GHz) based on the return loss of 10 dB, and the radiation patterns show as the omnidirectional shapes for the E-field and H-field. For analyzing the human effects, the proposed antenna is mounted on the mobile-phone case. The averaged peak SAR over 1 g and 10 g is simulated and measured when the input power is 0.25 W. We have checked the variation of the SAR values when the antenna is mounted 4 different directions, then checked the direction having a relatively higher SAR. The results also satisfied the limiting SAR values which are 1.6 W/kg and 2.0 W/kg averaged over 1 g and 10 g tissues respectively.

A Modified EGEAS Model with Avoided Cost and the Optimization of Generation Expansion Plan (회피비용을 고려한 EGEAS 모형 개발과 전원개발계획의 최적화)

  • 이재관;홍성의
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.17 no.1
    • /
    • pp.117-117
    • /
    • 1992
  • Pubilc utility industries including the electric utility industry are facing a new stream of privatization com-petition with the private sector and deregulation. The necewssity to solve now and in the future power supply and demand problems has been increasing through the sophisticated generation expansion plan(GEP) approach con-sidering not only KEPCo's supply-side resources but also outside resources such as non-utility generation(NUG) demand-side management (DSM). Under the environmental situation in the current electric utility industry a new approach is needed to acquire multiple resources competitively. This study presents the development of a modified electric generation expansion analysis system(EGEAS) model with avoided cost based on the existing EGEAS model which is a dynamic program to develope an optimal generation expansion plan for the electric utility. We are trying to find optimal GEP in Korea's case using our modified model and observe the difference for the level of reliabilities such as the reserve margin(RM) loss of load probability(LOLP) and expected unserved energy percent(EUEP) between the existing EGEAS model and our model. In addition we are trying to calculate avoided cost for NUG resources which is a criterion to evaluate herem and test possibility of connection calculation of avoided cost with GEP implementation using our modified model. The results of our case study are as follows. First we were able to find that the generation expansion plan and reliability measures were largely influenced by capacity size and loading status of NUG resources, Second we were able to find that avoided cost which are criteria to evaluate NUG resources could be calculated by using our modified EGEAS model with avoided cost. We also note that avoided costs were calculated by our model in connection with generation expansion plans.

Evaluation of Domestic CCPs(Coal Combustion Products) Quality by API Test Method (API시험법에 의한 국내 석탄회의 품질 평가)

  • Yoo, Sung-Won;Yu, Kyung-Geun;Cho, Young-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2013
  • Recently, recycling of industrial by-products and CO2 reduction have been important issues in the world. In this reason, applications and reuse of Fly ash as a binder for concrete, which is generated in thermoelectric power plant, have been one of the effective recycle methods. In order for Fly ash to be applied to concrete, Korean Standard(KS) has selected and managed quality such as $SiO_2$, fineness, specific gravity, ignition loss and activity index. However, there is a limits for activity index, whose test period required is at least 28 days or 91 days. Activity index is the critical indication standard to determine mechanical strength of concrete that contained Fly ash. To complement the disadvantage of test method, this research provided "API test method", which quickly measure Pozzolanic reaction of Fly ash can be considered as a alternative of activity index. Then, the adaptable API test method need to be investigated through comparative analysis with the test result of API, activity index and K-value. The test method can make evaluation of Fly ash quality faster and more accurate. As a result, most Fly ash produced in Korea has not been satisfied in the KS quality standard except water content and specific gravity, and especially fluidized bed boiler ash has its characteristics. Also, API, activity index and K-value have superior interrelationship. The interrelationship between API and activity index and K-value gets increased as the material age gets higher, so API test can be considered as very useful test method for Pozzolanic reaction evaluation of Fly ash.

Risk Factors of Work-related Low Back Pain in Manufacturing Workers (제조업 근로자들의 작업과 연관된 요통의 위험요인에 관한 연구)

  • Kim, D.H.;Shin, H.R.;Chun, J.H.;Kim, Y.W.;Kim, J.H.;Lee, C.U.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.26 no.1 s.41
    • /
    • pp.20-36
    • /
    • 1993
  • Work-related low back pain is one of the major factors that cause the loss of working power especially in actively working age, therefore controlling the work-related low back pain is one of the major issues in the field of industrial safety and health. This study was performed for detecting the risk factors and proposing the efficient control program of the work-related low back pain. The subjects were male workers employed at the manufacturing industry in Pusan with longer than 6 months' working duration. The data was collected by self-reported questionnaire and interview from May 1 to October 31,1992. The contents of questionnaire were as follows:. the experience of low back pain within the recent one month, general characteristics(age, marital status, education level, religion, regular exercise), physical characteristics(height, weight), employment status(working duration, daily working hours, rest during work, satis(action fur the job), type of work and working environments(posture, forward bending, lifting and movement, satisfaction for table and chair). The result was analyzed for 608 entire respondents by case-control comparative method. The number of cases was 152 with a history of work-related low back pain, so the relative frequency of self-reported work-related low back pain was 25.0%, and the number of controls was 344 without any history of low back pain. As a result, two characteristics of the employment status(working duration, satisfaction fur the job) and all characteristics of type of work and working environments showed a statistical significance between the case and control groups(p<0.01). The Oddb ratios of these variables for Work-related low back pain were calculated. They were 7.88 for the satisfaction fur chair, 7.86 for lifting and movement,3.31 for satisfaction for table, and 2.22 fur bending forward(p<0.01). And for the multivariate logistic regression analysis confirmed that unsatisfaction for table was independent risk factor for Work-related low back pain. In summary, though this study was based upon the self-reported questionnaire and the subjective complaints, the satisfaction for chair, lifting and movement, satisfaction for table, and bending forward concerned with the type of work and working environments were considered as the main factors causing the work-related low back pain, and the work-related low back pain may be preventable by the ergonomic control of these factors.

  • PDF

The Conflict over the Separation of Prescribing and Dispensing Practice (SPDP) in Korea: A Bargaining Perspective (의약분업을 둘러싼 갈등 : 협상론의 관점에서)

  • Lee, Kyung-Won;Kim, Joung-Hwa;T. K. Ahn
    • Health Policy and Management
    • /
    • v.12 no.4
    • /
    • pp.91-113
    • /
    • 2002
  • We report and analyze the Korean physicians' recent general strike over the implementation of the Separation of Prescribing and Dispensing Practice (SPDP) in which more than 18,000 private clinics and 280 hospitals participated. Utilizing game-theoretic models of bargaining we explain why the Korean physicians were so successful in organizing intense collective action against the government and securing very favorable policy outcomes. In particular, we highlight the role of distributional conflict among social actors in shaping the details of institutional reform. The introduction of the SPDP was a necessary first step in the overall reform of health care system in Korea. However, the SPDP was perceived to be a serious threat to the economic viability of their profession by the vast majority of Korean physicians who had long been relied on the profits from selling medicines to compensate for the loss of income due to the low service fee under the previous health care system. The strong political coalition among heterogeneous physicians enabled them to organize an intense form of collective action, the general strike. Thus, physicians were successful not only in dragging the government to a bargaining table, but also winning in the bargaining and securing an outcome vastly favorable to them. On the other hand, the lack of an overall reform plan in the health care policy area, especially the finance of the National Health Insurance and the need for maintaining an image as a successful reform initiator, motivated the government to reach a quick resolution with the striking physicians.

AT-DMB Reception Method with Eigen-space Beamforming Algorithm (고유 공간 빔형성 알고리즘을 이용한 AT-DMB 수신 방법)

  • Lee, Jae-Hong;Choi, Seung-Won
    • Journal of Broadcast Engineering
    • /
    • v.15 no.1
    • /
    • pp.122-132
    • /
    • 2010
  • AT-DMB system has been developed to increase data rate up to double of conventional T-DMB in the same bandwidth while maintaining backward compatibility. The AT-DMB system adopted hierarchical modulation which adds BPSK or QPSK signal as enhancement layer to existing DQPSK signal. The enhancement layer signal should be small enough to maintain backward compatibility and to minimize the coverage loss of conventional T-DMB service coverage. But this causes the enhancement layer signal of AT-DMB susceptible to fading effect in transmission channel. A turbo code which has improved error correction capability than convolutional code, is applied to the enhancement layer signal of the AT-DMB system for compensating channel distortion. However there is a need for other solutions for better reception of AT-DMB signal in receiver side without increasing transmitting power. In this paper, we propose adaptive array antenna system with Eigen-space beamforming algorithm which benefits beamforming gain along with diversity gain. We analyzed the reception performances of AT-DMB system in indoor and mobile environments when this new smart antenna system and algorithm is introduced. The computer simulation results are presented along with analysis comments.

Nano-scale Patterning on Diamond substrates using an FIB (FIB를 이용한 다이아몬드 기판 위의 나노급 미세 패턴의 형상 가공)

  • Song, Oh-Sung;Kim, Jong-Ryul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1047-1055
    • /
    • 2006
  • We patterned nano-width lines on a super hard bulk diamond substrate by varying the ion beam current and ion beam sources with a dual beam field ion beam (FIB). In addition, we successfully fabricated two-dimensional nano patterns and three-dimensional nano plate modules. We prepared nano lines on a diamond and a silicon substrate at the beam condition of 30 kV, 10 pA $\sim$ 5 nA with $Ga^+$ ion and $H_2O$ assisted ion sources. We measured each of the line-width, line-depth, etched line profiles, etch rate, and aspect ratio, and then compared them. We confirmed that nano patterning was possible on both a bulk diamond and a silicon substrate. The etch rate of $H_2O$ source can be enhanced about two times than that of Ga source. The width of patterns on a diamond was smaller than that on a silicon substrate at the same ion beam power The sub-100 nm patterns on a diamond were made under the charge neutralization mode to prevent charge accumulation. We successfully made a two-dimensional, 240 nm-width text of the 300-lettered Lord's Prayer on a gem diamond with 30 kV-30 pA FIB. The patterned text image was readable with a scanning electron microscope. Moreover, three dimensional nano-thick plate module fabrication was made successfully with an FIB and a platinum deposition, and electron energy loss spectrum (EELS) analysis was easily performed with the prepared nano plate module.

  • PDF

Analysis of Current Limiting Characteristics According to Fault Angles in Integrated Three-Phase Flux-Lock Type Superconducting Fault Current Limiting (일체화된 삼상 자속구속형 고온초전도 전류제한기의 사고각에 따른 전류제한 특성 분석)

  • Park, Chung-Ryul;Du, Ho-Ik;Yim, Seong-Woo;Hyun, Ok-Bae;Lim, Sung-Hun;Park, Hyoung-Min;Cho, Yong-Sun;Nam, Gueng-Hyun;Lee, Na-Young;Choi, Hyo-Sang;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.255-256
    • /
    • 2006
  • In this paper, we investigated the. characteristics of fault current limiting according to fault angle in the integrated three-phase flux-lock type SFCL in fault types such as the single-line-to-ground fault, the double-line-to-ground fault and the three-line-to-ground fault. When the SFCL is operating under normal condition, the magnetic flux generated between primary and secondary coils of each single phase is canceled out perfectly, so that the impedance of the SFCL is also not generated and the power system can be operated normally without any loss, However, if a fault occurs even in any phase out of three phases, quench happened in SFCL elements and the current flowing secondary coil is restricted abruptly. Finally, the balance of magnetic flux in whole SFCL system is destroyed, and the fault currents in every phase could be limited at the same time irrespective of the fault types. As a result, the developed SFCL in this study were operated normally as expected and the purpose of the integration of 3 phase current limiting was also achieved successfully. However, the fault current limiting characteristics of the SFCL was dependant on the quench characteristics of HTSC elements in each phase, and it was expected that the improvement of the SFCL could be possible through the introduction of HTSC elements which have better critical characteristics.

  • PDF

A Hydration Reaction and Strength Development Properties of Cement Using Pond Ash in Coal Fired Power Plant (화력 발전소 매립회를 치환한 시멘트의 수화반응 및 강도발현 특성)

  • Lee, Jae-Seung;Noh, Sang-Kyun;Shin, Hong-Chul
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.578-584
    • /
    • 2021
  • This study comparatively analyzed the properties of hydration reaction and strength development of four types of pond ash(PA) and fly ash(FA), aiming for the effective use of PA. The PA whose chlorine content was highest due to the seawater movement method had a faster setting time, higher cumulative heat, and greater initial strength development than those of FA due to the acceleration of the cement hydration reaction. However, the activity factor increase rate decreased after seven days of curing due to the rapid generation of early hydrates. The PA that contained impurities, such as a large amount of unburned carbon, had a delayed setting time due to the lower hydration reaction. Moreover, the strength was degraded in all curing ages. The PA whose chlorine content was lower due to the freshwater movement method and the amorphous content exhibited similar hydration reactivity and strength development characteristics compared to that of FA. The thermogravimetric analysis results verified that it had a similar level of Ca(OH)2 consumption and pozzolanic reactivity with that of FA. Conclusively, it is necessary to expand the application of the freshwater movement method and manage the ignition loss to raise PA's usability.

A CFD Study on Aerodynamic Performances by Geometrical Configuration of Guide Vanes in a Denitrification Facility (탈질 설비 내 안내 깃의 기하학적 형상에 따른 공력 성능에 대한 전산 해석적 연구)

  • Chang-Sik, Lee;Min-Kyu, Kim;Byung-Hee, Ahn;Hee-Taeg, Chung
    • Clean Technology
    • /
    • v.28 no.4
    • /
    • pp.316-322
    • /
    • 2022
  • The flow pattern at the inlet of the catalyst layer in a selective catalytic reduction (SCR) system is one of the key parameters influencing the performance of the denitrification process. In the curved diffusing parts between the ammonia injection grids and the catalyst layers, guide vanes are installed to improve flow uniformity. In the present study, a numerical simulation has been performed to investigate the effect of the geometrical configuration of the guide vanes on the aerodynamic characteristics of a denitrification facility. This application has been made to the existing SCR process in a large-scaled coal-fired power plant. The flow domain to be solved covers the whole region of the flow passages from the exit of the ammonia injection gun to the exit of the catalyst layers. ANSYS-Fluent was used to calculate the three-dimensional steady viscous flow fields with the proper turbulence model fitted to the flow characteristics. The root mean square of velocity and the pressure drop inside the flow passages were chosen as the key performance parameters. Four types of guides vanes were proposed to improve the flow quality compared to the current configuration. The numerical results showed that the type 4 configuration was the most effective at improving the aerodynamic performance in terms of flow uniformity and pressure loss.