A Study on the Analysis of Galloping for Power transmission line (송전선의 전선도약 해석에 관한 연구)

  • 김환성;변기식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.5
    • /
    • pp.1051-1057
    • /
    • 2001
  • In this paper, we deal with three types of modelling method for the analysis of galloping in power transmission line (PTL). The single mass model is obtained under linearization method and it is applied into f-order model. On these models, the nature frequencies of PTL are obtained and it makes an effects on the galloping directly. In simulation, we verify that the maximum magnitude of nature frequency depends on the galloping distance of PTL. Also from the analysis of frequency response, a few of reduction method for galloping are introduced which is effected by distance of PTL, wind velocity and icing types.

  • PDF

The Analysis of Power Line Galloping by Describing Function Method (Describing Function Method를 이용한 송전선의 전선도약(Galloping)현상 해석에 관한 연구)

  • 노창주;박한석;변기식
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.4
    • /
    • pp.339-345
    • /
    • 1992
  • Estimates of maximum amplitudes of conductor galloping are needed in order to determine appropriate phase-to-phase clearances on the overhead lines. One approach to obtaining these estimates is through the use of mathematical models of conductor galloping. Unfortunately, the models that consider both vertical conductor motion (Den Hartog type) and torsional conductor motion are often too complex for practical use. However, the estimates of maximum amplitude obtained from galloping models that assume only vertical (Den Hartog type) conductor motion tend to be too conservative. This paper presents the DF method to obtain the estimates of the amplitude and the frequency of galloping limit cycle, along with the wind pressure at which they occur, from a nonlinear dynamic model that considers both Den Hartog type and torsional conductor motion. From these results, the useful data for the line design guide and further insight into the mechanism of the conductor galloping are obtained.

  • PDF

Effect Analysis of Spacer Stiffness and Interval on Galloping of Power Transmission Lines (스페이서 강성과 간격이 송전선 갤러핑에 미치는 영향분석)

  • Oh, Yun-Ji;Sohn, Jeong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.1
    • /
    • pp.52-58
    • /
    • 2019
  • Due to icing and snow, power transmission lines have asymmetric cross sections, and their motion becomes unstable. At this time, the vibration caused by the wind is called galloping. If galloping is continuous, short circuits or ground faults may occur. It is possible to prevent galloping by installing spacers between transmission lines. In this study, the transmission line is modeled as a mass-spring-damper system by using RecurDyn. To analyze the dynamic behavior of the transmission line, the damping coefficient is derived from the free vibration test of the transmission line and Rayleigh damping theory. The drag and lift coefficient for modeling the wind load are calculated from the flow analysis by using ANSYS Fluent. Galloping simulations according to spacer stiffness and interval are carried out. It is found that when the stiffness is 100 N/m and the interval around the support is dense, the galloping phenomenon is reduced the most.

Sleet Jump Simulation of Power Transmission Line by Using Multi-Body Dynamics (다물체 동역학을 이용한 송전선의 슬릿점프 시뮬레이션)

  • Kim, Ji-Wook;Sohn, Jeong-Hyun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.20 no.5
    • /
    • pp.431-439
    • /
    • 2017
  • Since the power transmission line(PTL) passes through the high mountain and heavy snowfall region, it is necessary to keep the stability of the PTL. In this study, PTL is modeled as a mass-spring-damper system by using RecurDyn. The lumped mass model is verified by calculated from the simulation comparing the deflection analysis according to the sag and tension. In order to analyze the dynamic behavior of PTL, a damping coefficient for a multi-body model is derived by using the free vibration test and Rayleigh damping theory. Sleet jump simulation according to the region is performed. The maximum jump height, icing sag and amount of jump are confirmed. Also, the amount of jump and the reaction force at the supporting point according to the tension and load of ice are analyzed, respectively. As a result, it is noted that the amount of jump and reaction force are influenced more by the load of ice than by the tension of PTL.

Study and Survey of Operating Efficiency with Cool Storage System (빙축열냉방시스템의 운전효율에 관한 조사연구)

  • 손학식;심창호;김강현;김재철
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study is to maintain high efficiency and reasonable use of cool thermal storage systems operated in the domestic building sector. As the result of efficiency test from the five types of operated cool storage systems on the condition that COP ranges are 2.6 to 3.4 during the day time and 2.1 to 3.0 during the night time and it decreased by more than 30% of rated COP given 3.8 to 3.0. The Analysis of cool storage rate shows that only 3 (21.4%) systems out of 15 buildings hold to over 40% capacity for its total capacity. To prevent the decrease in operating efficiency, it should correct the malfunction of 3-way valve and expansion valve and the mistake of control values for schedule program and increase cooling tower capacity. In order to improve piping line, it needs bypass brine line off refrigerator, separation of chilled water line with Ice Slurry system at day and night time and speed control of chilled and warm water pumps. This study does require the more studies on improving difficulty of increasing cooling load with Ice on Coil system, waterproofing with Ice Ball system, COP drop during the night time with Ice Lens, low operating temperature during the day time with Ice Slurry and increasing of Power loss due to hot gas de-icing with Ice Harvest in the future.