• 제목/요약/키워드: Power line

검색결과 6,044건 처리시간 0.033초

Development of Floating Power Supply for Current Measurement System of High Voltage Power Line

  • Oota, Ichirou;Hattori, Hiroaki;Nishiyama, Eiji;Matsuda, Toyonori;Kawano, Mitsunori;Kuwanami, Kenji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.88.5-88
    • /
    • 2002
  • A new floating power supply for the current measurement system of a high voltage power line is developed. It is confirmed that, the current measurement system can stably transfer the signal of the power line current about 50 - 300 A by using the proposed power supply. The excellent characteristics are obtained by the steady-state and transient experiments of the proposed circuit. $\textbullet$ The right figure shows the external view of the trial measurement system for 6.6 kV. In order to see the inside, 120 degrees of the insulator is cut. The toroidal coil for the power supply and the Rogowskii coil for the current sensor are both divided into two and fixed on the power line as...$\textbullet$ The proposed circuit can supply +5V and -5V voltages without using a solar cell and/or a battery.

  • PDF

Wireless Power Transfer Technology in On-Line Electric Vehicle

  • Ahn, Seung-Young;Chun, Yang-Bae;Cho, Dong-Ho;Kim, Joung-Ho
    • Journal of electromagnetic engineering and science
    • /
    • 제11권3호
    • /
    • pp.174-182
    • /
    • 2011
  • The On-line Electric Vehicle (OLEV) is an electric transport system in which the vehicle's power is transferred wirelessly from power lines underneath the surface of the road. Advantages of the OLEV include reducing battery size and cost to about 20 percent of that of conventional battery-powered electric vehicles, thereby minimizing the vehicle's weight and price, as well as the cost of charging the system. In this paper, we introduce a wireless power transfer mechanism to maximize the electrical performance of the power transfer system. Power transfer capacity, power transfer efficiency, and magnitude of leakage in the electromagnetic field (EMF) are analyzed, and the optimization methodology of the design parameters is discussed.

고효율 운전이 가능한 지능형 무정전 전원장치에 관한 연구 (A Study of Smart Uninterruptible Power Supply Capable High Efficiency Drive)

  • 엄태욱
    • 조명전기설비학회논문지
    • /
    • 제27권5호
    • /
    • pp.61-66
    • /
    • 2013
  • In this paper, a control scheme with the capability of high efficiency, which is realized by predicting the conditions of a load power and an input power, is proposed for the uninterruptible power supply (UPS). Generally, on-line UPS system supplies a constant voltage and a constant frequency (CVCF). However, the efficiency of the On-line UPS system can be reduced due to the switching losses of semiconductor devices during the power conversion. The these losses are improved by the proposed smart UPS with the high efficiency drive system, which is realized by analysing and predicting the conditions of a load power and an input power.

하프변환을 이용한 항공영상의 전력선 검출 (Power Line Detection of Arial Images Using Hough Transform)

  • 김동욱;강정혁
    • 한국전자통신학회논문지
    • /
    • 제5권2호
    • /
    • pp.171-179
    • /
    • 2010
  • 일반적으로 송전용 전력선 및 절연체의 감시 및 유지 보수를 위한 한 방법으로서 유인 헬기를 이용하여 가시영상 및 적외선 열영상을 측정하고 이를 분석하는 방법이 이용되고 있다. 이러한 감시 및 유지보수 방법을 무인화하기 위해 항공 영상으로부터 전력선의 자동 추출에 대한 연구가 진행 되어 왔다. 본 논문에서는 열영상 기반의 전력선 영상에서 전력선을 효과적으로 검출하기 위해 Hough변환 및 전력선의 방향성을 이용하는 방법을 제안하고자 한다. 제안된 방법은 얻어진 에지성분을 바탕으로 하프변환을 하고 방향성분을 분석하여 전력선의 분포특성을 얻고 이를 이용하여 전력선을 검출한다. 특히 얻어진 항공영상에서 전력선이 평행한 경우와 원근법에 의해 평행하지 않은 경우 모두 양호한 검출특성을 보인다. 모의실험을 통하여 이러한 전력선 검출 방법은 배경 영상의 복잡성과 항공영상의 전력선 방향에 무관하게 유효한 방법임을 확인할 수 있었다.

전력선 통신을 이용한 집단주택 안전관리 시스템 (Security Monitoring System for Apartment House Building Using Paver Line Carrier)

  • 김인수;김관호;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.476-478
    • /
    • 1993
  • Instead of installing new communication wiring to each house in the apartment house building. the power distribution network. which is already installed in the building. can be use as communication medium. In a safty management, by adoption of power line communication system, at remote we can monitor safty related sensors such as fire, gas leakage, burglar intrusion and emergency call which are located at each house. From this viewpoint, we developed security monitoring system for apartment house building using power lines. Security monitoring system consists of Power Line Communication-Sub Controller (PLC-SC). Power Line Communication-Main Controller (PLC-MC) and Management System (MS). Between a PLC-MC and a PLC-SC, the transmission rate is 1200 bps in power lines and modulation technique is frequency shirt keying (FSK). In between a PLC-MC and a MS, the transmission rate is 1200 bps in communication line (RS-485). As a result of this research. transmission loss is 0.1dB per meter of intrabuilding distribution network. Transmission can be reach in 250 meters. So it is enough to communicate for security monitoring system in apartment house building.

  • PDF

배전 선로에 연계된 다수대의 변동성 재생에너지 발전 시스템의 출력 유효전력 변동에 따른 무효전력 제어를 이용한 전압 변동 보상 (Compensation of Voltage Variation Using Active Power-Dependent Reactive Power Control with Multiple VRE Systems Connected in a Distribution Line)

  • 이상훈;김수빈;송승호
    • 풍력에너지저널
    • /
    • 제9권4호
    • /
    • pp.47-56
    • /
    • 2018
  • This paper introduces an active power dependent standard characteristic curve, Q(P) to compensate for voltage variations due to the output of distributed generation. This paper presents an efficient control method of grid-connected inverters by comparing and analyzing voltage variation magnitude and line loss according to the compensation method. Voltage variations are caused not only by active power, but also by the change of reactive power flowing in the line. In particular, the system is in a relatively remote place in a coastal area compared with existing power plants, so it is relatively weak and may not be suitable for voltage control. So, since it is very important to keep the voltage below the normal voltage limit within the specified inverter capacity and to minimize line loss due to the reactive power. we describe the active power dependent standard characteristic curve, Q(P) method and verify the magnitude of voltage variation by simulation. Finally, the characteristics of each control method and line loss are compared and analyzed.

철도 전차선의 보조전원을 위한 전력선 커플러 연구 (Study on Power Line Coupler for Auxiliary Power to Overhead Line)

  • 이건복;이경표;김명룡;이수길;창상훈
    • 한국전자파학회논문지
    • /
    • 제29권7호
    • /
    • pp.566-569
    • /
    • 2018
  • 철도 전차선 구조에 고주파 전력을 인가할 수 있는 전력선 커플러에 대해 분석하였다. 전차선 구조는 고압의 환경에서 보조전원을 공급하기가 어렵고, 먼 거리까지 전력을 전달하는 방법이 필요하다. 이를 위해 코어를 사용하지 않는 로고스키 코일에 공진을 활용하는 방법을 제안하였다. 조가선, 전차선, 드로퍼로 구성된 간이 전차선 구조를 제작하였고, 여러 사이즈의 커플러를 제작하여 조가선에 연결한 다음 일정 거리만큼 떨어진 두 커플러의 전달 특성을 비교하였다. 가장 성능이 좋은 커플러에 매칭 회로를 적용하여 측정한 결과, 2.5 m 거리에서 53 %의 전달 효율을 나타내었다. 제안하는 방법은 전차선과 같은 특수한 구조물에서 기존의 도선을 활용하여 보조전원을 인가할 수 있음을 보여준다.

On-Line 실시간 성능감시 시스템을 이용한 화력발전소 운전 Parameter 값 비교분석 (Comparison of properties at Fossil Power Plant by On-Line Real Time Performance Monitoring System)

  • 정훈;박두용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3501-3505
    • /
    • 2007
  • As the power plant industry has been changed into competition structure, power generation companies do more with less by increasing capacity and lowering operation costs. In order to achieve this goals, an on-line real-time performance monitoring system has been needed to introduced to fossil power plant. The system represents a suite of related software modules which consist of on-line data, and on-line performance modules. This system can help the plant staff get the most out of their facilities by continuously monitoring deviations in equipment performance and the impact on those deviations on plant power, heat rate and operating cost. This paper shows the comparison of design value with acceptance test and current(measured) value.

  • PDF

전력선 주파수를 이용한 가시광 채널의 시분할 전송 (Time Division Transmission of Visible Light Channels Using Power Line Frequency)

  • 이성호
    • 센서학회지
    • /
    • 제23권5호
    • /
    • pp.349-355
    • /
    • 2014
  • In this paper, we developed a new method to transmit multiple visible light channels in time division mode using the AC power line frequency in order to prevent the crosstalk between adjacent optical signals. Synchronizing pulses are generated from the 220 V power line, and one pulse period is subdivided into several time slots for visible light channels. Each channel transmits data in a predefined time slot without interfering adjacent channels. In experiments, synchronizing pulses with a repetition rate of 240 Hz were generated from the 60 Hz power line, and three VLC channels with a bit rate of 9.6 kbps transmitted data independently using the time slots between synchronizing pulses. This configuration is very useful in constructing time division VLC networks for multiple sensors.

고속 전력선통신 시스템의 비이진 터보 부호 성능 (Performance of Double Binary Turbo Code for Power Line Communicaion Systems)

  • 이재선;양재수;우상규;윤병완;김진영
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.72-77
    • /
    • 2009
  • In this paper, performance of a turbo-coded PLC system is analyzed and simulated in a power line communication channel. Since the power line communication system typically operates in a hostile environment, turbo code has been employed to enhance reliability of transmitted data. The performance is evaluated in terms of bit error probability. As turbo decoding algorithms, Max-Log-MAP algorithms are chosen and performances are compared. The results in this paper can be applied to OFDM-based high-speed power line communication systems

  • PDF