• Title/Summary/Keyword: Power inverter

Search Result 3,965, Processing Time 0.031 seconds

Control of Motor Drives Fed by PFC Circuits without DC-Link Electrolytic Capacitors

  • Kim, Kwang-Man;Kim, Eung-Ho;Choi, Jong-Woo
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1067-1074
    • /
    • 2018
  • This paper presents a control method for variable-speed motor drives that do not use a DC-link electrolytic capacitor. The proposed circuit consists of a power factor correction converter for boosting the DC-link voltage, an inverter for driving the motor, and a small DC-link film capacitor. By employing a small DC-link capacitor, the proposed circuit that is small, and a low cost and weight are achieved. However, because the DC-link voltage varies periodically, the control of the circuit is more difficult than that of the conventional method. Using the proposed control method, an inverter can be controlled reliably even when the capacitance of the DC-link capacitor is very small. Experiments are performed using a 1.5-kW inverter with a $20-{\mu}F$ DC-link capacitor, and the experimental results are analyzed thoroughly.

A Test System of Valve and Poles for Large Scale Inverter using Resonant Circuit (공진회로를 이용한 대용량 인버터 구성용 밸브 및 폴 시험설비에 관한 연구)

  • Han, Young-Seong;Chung, Chung-Choo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.971-976
    • /
    • 2011
  • This paper proposes a test system for a valve and poles building blocks used for large scale inverters such as STATCOM, SSSC, UPFC and VSC HVDC. Power semiconductors in the valve are normally connected in series to withstand switching voltage much larger than the voltage rating of a single power semiconductor. Therefore, there is a need to verify if the dynamic voltage sharing during switching in a valve is satisfactory. In this paper, we propose a test system that provides the necessary test condition: voltage and current in the valve using resonant circuits. A test scheme for a single phase inverter consisting two poles is also proposed. The performance of the inverter pole has to be verified at the factory test, before the system is installed at the site to secure the reliability of the system. The proposed scheme makes it possible to confirm if the pole can withstand voltage and current switching condition and handle loss.

Development of the Bidirectinal DC-DC Converter Control Algorithm for Hybrid Electric Vehicles (하이브리드 전기자동차용 양방향 DC-DC Converter제어 알고리즘 개발)

  • Oh Doo-Yong;Gu Bon-Gwan;Nam Kwang-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.346-349
    • /
    • 2004
  • The design of DC-DC converters for power electronic interfaces in power management systems for Hybrid Electric Vehicle (HEV) is a very challenging task. In this paper, the considered topology is the hi-directional buck-boost converter and inverter system. If we make the converter side DC link current the same as the inverter side DC link current in a converter-inverter system, no current will flow through the BC link capacitor and as a result, no DC link voltage variation occurs. This leads to the possibility of reducing small th size of DC link capacitors which are expensive, bulky. Therefore we propose the converter current controller which can manage to match inverter and converter current at the DC link.

  • PDF

HID Ballast using Soft Switching Multi Level Inverter (Soft Switching Multi Level Inverter를 이용한 HID용 Ballast)

  • Lee Jang-Sun;Kim Yoon-Ho;Kim Soo-Hong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.628-634
    • /
    • 2004
  • The soft switching is applied to the multi-level inverter to enhance the characteristics of HID(High Intensity Discharge) Ballast in headlight of vehicle. The electrical properties are investigated. The available modeling of the ballast in steady-state is calculated using mathematical method and the result is used in analyzing the power characteristics and design of the system. Finally the designed system md modeling is confirmed by the experiment.

The Study of Inverter Module with applying the RC(Reverse Conduction) IGBT (RC(Reverse Conduction) IGBT를 적용한 Inverter Module에 대한 연구)

  • Kim, Jae-Bum;Park, Shi-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.359-359
    • /
    • 2010
  • IGBT(Insulated Gate Bipolar Transistor) 란 MOS(Metal Oxide Silicon) 와 Bipolar 기술의 결정체로 낮은 순방향 손실(Low Saturation)과 빠른 Speed를 특징으로 기존의 Thyristor, BJT, MOSFET 등으로 실현 불가능한 분양의 응용처를 대상으로 적용이 확대 되고 있고, 300V 이상의 High Power Application 영역에서 널리 사용되고 있는 고효율, 고속의 전력 시스템에 있어서 필수적으로 이용되는 Power Device이다. IGBT는 출력 특성 면에서 Bipolar Transistor 이상의 전류 능력을 가지고 있고 입력 특성 면에서 MOSFET과 같이 Gate 구동 특성을 갖기 때문에 High Switching, High Power에 적용이 가능한 소자이다. 반면에, Conventional IGBT는 MOSFET과 달리 IGBT 내부에 Anti-Parallel Diode가 없기 때문에 Inductive Load Application 적용시에는 별도의 Free Wheeling Diode가 필요하다. 그래서, 본 논문에서 별도의 Anti-Parallel Diode의 추가 없이도 Inductive Load Application에 적용 가능한 RC IGBT를 적용하여 600V/15A급 Three Phase Inverter Module을 제안 하고자 한다.

  • PDF

The characteristic analysis of inverter air-conditioner power system with low power dissipation type (저소비전력형 인버터 에어컨 전원시스템의 특성 해석)

  • Park, Young-Jo;Suh, Ki-Young;Mun, Sang-Pil;Kim, Young-Mun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.52-54
    • /
    • 2003
  • By having the proposed circuit using a smaller one with a small reactor, the output voltage is boosted-up and improves the input of the current waveform. Therefore, we are able to follow the harmonics guidelines Greater power and efficiency is obtained from the proposed circuit. This also reduces some switching loss and holds the over-shooting by using the inverter of eliminated dead-time HPWM which is a non-linear impedance of the circuit to make up the diodes, the capacitance, and the reactor. We compared the conventional PWM inverter and proposed HPWM inverter.

  • PDF

Analysis and Control of Cost-Effective Topologies for Single Phase to Three Phase Power Converter (비용절감형 단상-삼상 전력변환기 구조의 해석 및 제어)

  • Lee, Hae-Chun;Park, Tae-Yeol;Kim, Gi-Taek
    • Journal of Industrial Technology
    • /
    • v.19
    • /
    • pp.217-226
    • /
    • 1999
  • A single phase to three phase power converter with cost effective and simple structure is proposed. The converter consists of rectifier and inverter. The rectifier is composed of a half wave rectifier, a dc link capacitor, and a current limiting inductor, and the inverter is of only two switches with PWM control. For negative sequence operation the inverter output voltage leads the line input by $60^{\circ}$, and for positive sequence operation the inverter output voltage leads by $60^{\circ}$. We can see that positive sequence operation shows higher output voltage, slight harmonic distortion(2%), and better performances such as high efficiency and high power factor. A mathematical model for system analysis is provided, and specifications for selection and control scheme both for start-up and for steady state are analyzed. comparison and operational limits of positive and negative sequence operation are performed, and simulations and experiments are executed to verify the proposed.

  • PDF

A Study on the Parameter Optimization of Inverter for Induction Heating Cooking Appliance (유도가열 조리기기용 인버터 파라미터 최적화에 관한 연구)

  • Kang, Byung-Kwan;Lee, Se-Min;Park, Jung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.77-85
    • /
    • 2009
  • With the advent of power semiconductor switching devices, power electronics relating to high frequency electromagnetic eddy current based induction heating technology have become more suitable and acceptable. This paper presents high-frequency induction heating cooking appliance circuit based on the zero current switching-PWM single ended push-pull(ZCS-PWM SEPP) resonant inverter added AC-DC converter. This inverter uses pulse-width-modulation(PWM) control method with active auxiliary quasi-resonant lossless inductor snubbers and a switched capacitor. To improved the transient performance, the PI controller is applied for this system. For the systematic parameter optimization of the PI controller, the gradient-based optimization algorithm is applied. The performance of optimized parameters is evaluated using simulation and experimental test. These results show that the proposed systematic optimal tuning method improve the transient performances of this system.

A Scheme for Adoption of Regenerative Inverter in DC Transit System (직류급전시스템 회생용 인버터 개발 및 실계통 적용 방안)

  • Kim, Joo-Rak;Han, Moon-Seob;Chang, Sang-Hoon;Kim, Jung-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1044-1045
    • /
    • 2008
  • DC transit system has been adopted in the metropolitan area, Korea since 1974. EMU in this system always reiterates that acceleration and retardation. When EMU decelerates using electric breaking, regenerative power occurs. Regenerative power can be consumed in vicinity EMU on the same line or in resistor. If DC transit system has inverter for reusing regenerative power, Energy efficiency in DC transit system will be increased. This paper present the adoption of developed inverter in commercial railway line and the test result procedure of developed inverter is presented.

  • PDF

Development of a Large Scale STATCOM Using Double-Connected Multistep Inverter (이중접속방식의 멀티스텝 인버터를 이용한 대용량 STATCOM의 개발)

  • 김태훈;배영상;최세완;이왕하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.36-41
    • /
    • 2004
  • In this paper a large scale STATCOM using double-connected multi-step inverter is proposed and operating principle along with control method is detailed. A simple auxiliary circuit including an interphase transformer is employed to improve output voltage waveform of 12-step into 36-step. The proposed scheme could be a cost effective approach in high power applications such as 10MVar to 30MVar STATCOM. Experimental results from a 2KVA laboratory prototype show validity of the proposed method.