Development of 6kW ZVS Boost Converter by 4-Parallel Operation (4-병렬 제어 기법을 적용한 6kW 영전압 스위칭 승압형 컨버터 개발)

  • Rho, Min-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.86-92
    • /
    • 2009
  • This paper presents development of 6kw ZVS(Zero Voltage Switching) boost converter by 4-parallel operation. To realize a high capacity converter with 6 kw, 4-parallel operation of 1.5kW unit module is proposed in this paper. To meet high ratio input to output voltage, isolated type booster converter is designed. To achieve ZVS operation of 4-switches of full bridge and protect a voltage overshoot caused by switch turn-off, simple active-clamp circuit is applied to the primary side. For parallel operation of 4-modules, master-slave control method is proposed to achieve input current sharing of 4-unit converter modules accurately. For performance tests, simulation is carried out. Also, load and experimental tests of the developed booster converter, 230Vdc/6kW, are carried out under various conditions. For field tests, the developed converter is applied for boosting a battery power to high DC_link voltage for a VSI inverter which starts a micro-turbine(MT) installed in vehicle and it's performance is verified through high speed motoring a MT up to tens of thousands of rpm.

Comparative study of proportional-integral, proportional-resonant, and predictive deadbeat controllers in a PV PCS (태양광 전력변환장치의 PI, PR 및 PD 제어기 비교 연구)

  • Le, Dinh-Vuong;Kim, Chang-Soon;Hwang, Chul-Sang;Park, Minwon;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1050-1051
    • /
    • 2015
  • In industry, there are several different controllers which can be implemented for power conditioning systems (PCS) such as proportional-resonant (PR), predictive deadbeat (PD), or proportional-integral (PI) controller. But there are not any comparison studies about these controllers. To investigate the differences between the three types of the controllers, this paper presents a comparative study of PR, PI, and PD controllers in a photovoltaic (PV) PCS. These controllers are designed mathematically and simulated for the comparative analysis. The PI controller is designed in the rotating reference (dq) frame. The PR and PD controllers are implemented in the natural (abc) reference frame. The PCS is composed of a DC-DC boost converter and a full bridge inverter. The filter of the PCS is an LCL filter including a passive damping resistor. The parameters of PCS are 3 kW, 25 kHz switching frequency and 220 V-60 Hz grid voltage. The comparison results between these controllers for the grid-connected PCS are clearly shown. The simulation results demonstrate the detailed characteristics of each controller for the PV PCS in order to choose the controller for individual target properly.

  • PDF

The Analysis of Dynamic characteristics and Modeling of Brushless DC Motor (Brushless DC 전동기의 모델링과 동특성 해석)

  • 전내석;조성훈;안병원;이성근;김윤식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.408-413
    • /
    • 2001
  • DC motor has widely been used in the field of variable-speed driving unit since it is easy to control flux and torque precisely but it is troublesome to check and maintain periodically. In addition, there are difficulties in hish power and high speed running due to rectifying limit of commutator, and are a lot of restrictions in installation. Therefore, speed control in BLDC(Brushless DC) motor has seriously been studied for a long while. In this paper, a mathematical model of BLDC motor driven by PWM inverter is developed. Dynamics and steady-state characteristics of BLDC motor are simulated and analyzed with a series of experiment for the parameter estimation : torque, speed, phase voltage and current.

  • PDF

The Design and An릴ysis of the Piezoelectric Inverter to Drive EEFL for a Large Screen (대화면 Backlight를 위한 EE리 구동용 압전 인버터 설계 및 분석)

  • Park Hong-Sun;Yang Seung-Hak;Lim Young-Cheol;Han Keun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.504-507
    • /
    • 2006
  • 현재 LCD(Liquid Crystal Display)용 광원으로서 주로 냉음극 방전램프(CCFL : Cold Cathode Fluorescent Lamp)가 사용되고 있으며, 그 외 LED를 비롯해서 외부전극 방전램프(EEFL: External Electrode Fluorescent Lamp), 면광원(FFL : Flat Fluorescent Lamp), 전계 방출램프(FEL : Field Emission Lamp)등 다른 광원에 대한 적용도 활발히 진행되고 있다. 본 논문에서는 멀티램프 구동이 유리하여 인버터 개수를 줄일 수 있는 장점을 가지고 있는 EEFL을 사용하였으며, 변압기의 자체 손실을 줄이고 소형화가 가능하며, 높은 승압 비를 갖는 압전 변압기를 병렬로 연결하여 멀티램프 구동이 가능하도록 하였다. 최적의 EEFL 구동회로를 구성하기 위해서 Push-Pull 타입의 압전 인버터를 설계하였으며, 설계된 인버터 회로에 대한 시뮬레이션 분석을 수행하고, 향후 여러 형태의 구동 방법을 적용하므로 서 압전 변압기로도 대화면 멀티 램프 구동용 인버터의 제작이 가능함을 제시하였다.

  • PDF

Design of digital Controller for Fuel Cell Inverter using Error Space Approach (오차 공간 접근법을 이용한 연료전지용 인버터 제어기 설계)

  • Park Ga-Woo;Yeom Sang-Gu;Kim Hyung-Chul;Lee Jin-Mok;Kim Soo-Cheol;Lee Jae-Moon;Jung Hun-Sun;Choi Jae-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.65-67
    • /
    • 2006
  • 연료전지용 전력변환 시스템에서 기존의 PID 제어기의 해석적인 해를 얻는 것은 매우 어려운 일이다. 최근, UPS용 CVCF 시스템에서 오차 공간 접근법을 이용한 새로운 제어알고리즘을 바탕으로 시스템의 제어기의 제어상수를 해석적으로 접근하여 좋은 성능을 얻은 바 있다. 오차 공간 접근법은 해석적으로 시스템의 응답속도 및 오버슈트를 임의의 제한범위 내로 설계할 수 있도록 하는 제어할 수 있는 장점이 있다. 이러한 UPS 시스템의 제어기 설계방법을 유사한 구조의 연료전지의 인버터 제어기 설계에 적용하여 해석적으로 제어기의 제어상수를 얻고 시뮬레이션을 통하여 제어기가 안정하며 빠른 응답속도를 가지는 것을 확인한다.

  • PDF

A Simple Control Strategy for Balancing the DC-link Voltage of Neutral-Point-Clamped Inverters at low modulation index (Neutral-Point-Clamped 인버터의 저 변조지수에서 DC 링크 전압 균형을 위한 간단한 컨트롤 기법)

  • Ma C.S.;Kim T.J.;Kang D.W.;Hyun D.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.560-564
    • /
    • 2003
  • This paper proposes a simple control strategy based on the discontinuous PWM(DPWM) to balance the DC-link voltage of three-level Neutral-Point-Clamped(WPC) inverters at low modulation index. New DPWM methods in multi-level inverter are also introduced. The proposed DPWM method changes the path and duration to flow the neutral point current out of or into neutral point of the DC-link and it makes the overall fluctuation of the DC-link voltage zero during a sampling time of reference voltage vector. Therefore, the voltage of the DC-link can be balanced fairly well and also the voltage ripple of the DC-link is reduced significantly. Moreover, comparing with conventional methods, the proposed strategy is very simple. The validity of the proposed DPWM method is verified by experiment

  • PDF

A Symmetric Carrier Technique of CRPWM for Voltage Balance Method of the Flying Capacitor Multi-level Iinverter (플라잉 커패시터 멀티-레벨 인버터의 커패시터 전압 균형을 이루기 위한 캐리어 비교방식을 이용한 캐리어 대칭 기법)

  • Jeon J.H.;Kim T.J.;Kang D.W.;Hyun D.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.606-610
    • /
    • 2003
  • This paper presents a simple carrier symmetric method for the voltage balance of flying capacitors in FCMLI(flying capacitor multi-level inverter). To achieve the voltage balance of flying capacitors, the utilization of each carrier must be balanced during a half-cycle of the switching period such as PSPWM(Phase-Shifted PWM). However, the CRPWM(Carrier Redistribution PWM) method causes the fluctuation of flying capacitor voltages because the balanced utilization of carriers is not achieved. Moreover, it does not consider that the load current change has an influence on flying capacitor voltages by assuming that the current flows Into the load. To overcome the drawbacks of CRPWM, it is modified by the technique that carriers of each band are disposed symmetrically at every fundamental period. Firstly, the CRPWN method is reviewed and the theory on voltage balance of flying capacitors is analyzed. The proposed method Is introduced and is verified through the experiment result.

  • PDF

A Study of Using Optimal Hysteresis Band Amplitude for Direct Torque Control of Induction Motor (유도전동기 직접토크제어의 히스테리시스 밴드 크기의 최적화에 관한 연구)

  • Jeong B.H.;Kim S.K.;Park J.K.;Oh G.K.;Cho G.B.;Baek H.L.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.812-815
    • /
    • 2003
  • Most of all, DTC drive is very simple in its implementation because it needs only two hysteresis comparator and switching vector table for both flux and torque control. The switching strategy of a conventional direct torque control scheme which is based on hysteresis comparator results in a variable switching frequency which depends on the speed, flux, stator voltage and the hysteresis of the comparator. The amplitude of hysteresis band greatly influences on the drive performance such as flux and torque ripple and inverter switching frequency. In this paper the influence of the amplitudes of flux and torque hysteresis bands and sampling time of control program on the torque and flux ripples are investigated. Simulation results confirm the superiority of the DTC under the proposed method over the conventional DTC.

  • PDF

Maximum Torque Control of IPMSM Drive using Optimal Current (최적전류를 이용한 IPMSM 드라이브의 최대토크 제)

  • Baek, Jeong-Woo;Ko, Jae-Sub;Choi, Jung-Sik;Kang, Sung-Jun;Jang, Mi-Geum;Mun, Ju-Hui;Chung, Dong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.57-58
    • /
    • 2010
  • This paper proposes maximum torque control of IPMSM drive using optimal current. This control method is applicable over the entire speed range which considered the limits of the inverter's current and voltage rated value. For each control mode, a condition that determines the optimal d-axis current $i_d$ for maximum torque operation is derived. This paper considers the design and implementation of novel technique of high performance speed control for IPMSM using multi-MFC and ANN controller. Also, this paper proposes maximum control of IPMSM drive using approximation method. This method is decreased the burden of digital signal process(DSP) in calculation of optimal current. This paper proposes the analysis results to verify the effectiveness of the MFC and ANN controller. Also it verifies the validity of maximum torque control of IPMSM drive with optimal current.

  • PDF

Maximum Torque Control of IPMSM Drive with LM-FNN Controller (LM-FNN 제어기에 의한 IPMSM 드라이브의 최대토크 제어)

  • Nam Su-Myung;Choi Jung-Sik;Chung Dong-Hwa
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.2
    • /
    • pp.89-97
    • /
    • 2006
  • Interior permanent magnet synchronous motor(IPMSM) has become a popular choice in electric vehicle applications, due to their excellent power to weight ratio. The paper is proposed maximum torque control of IPMSM drive using learning mechanism-fuzzy neural network(LM-FNN) controller and artificial neural network(ANN). The control method is applicable over the entire speed range and considered the limits of the inverter's current and voltage rated value. For each control mode, a condition that determines the optimal d-axis current $i_{d}$ for maximum torque operation is derived. This paper considers the design and implementation of novel technique of high performance speed control for IPMSM using LM-FNN controller and ANN controller. The hybrid combination of neural network and fuzzy control will produce a powerful representation flexibility and numerical processing capability. Also, this paper is proposed speed control of IPMSM using LM-FNN and estimation of speed using ANN controller. The back propagation neural network technique is used to provide a real time adaptive estimation of the motor speed. The proposed control algorithm is applied to IPMSM drive system controlled LM-FNN and ANN controller, the operating characteristics controlled by maximum torque control are examined in detail. Also, this paper is proposed the analysis results to verify the effectiveness of the LM-FNN and ANN controller.