• Title/Summary/Keyword: Power fluctuation

Search Result 603, Processing Time 0.028 seconds

Pulse Laser Power Stabilization Using PID Control Method (PID 제어기법을 이용한 펄스 레이저 출력 안정화에 관한 연구)

  • Ryoo, Hoon-Chul;Kwak, Seung-Woo;Kang, Dong-Won;Kim, Kyoung-Sik;Hahn, Jae-Won
    • Laser Solutions
    • /
    • v.9 no.2
    • /
    • pp.17-22
    • /
    • 2006
  • In this study, PID control method was applied to decrease the power fluctuation of the pulse laser which is one of the major processing variables in laser machining process. To stabilize the power fluctuation of the pulse laser, we averaged 10 pulse outputs of Nd:YAG laser operating in 10Hz using boxcar averager, and with taking this averaged output as an input signal, we conducted PID control using optical attenuator which is consisted of half wave plate attached on the stepping motor and polarizer. When PID control was not enabled, the power fluctuation was 4.71% and with PID control, the power fluctuation was 1.86% for 2 hours and 1 hour respectively. As a result, we stabilized the power fluctuation of the pulse laser by 60.5%

  • PDF

Pulse Laser Power Stabilization Using PID Control Method (PID 제어기법을 이용한 펄스 레이저 출력 안정화에 관한 연구)

  • Ryu, Hoon-Chul;Kwak, Seung-Woo;Kang, Dong-Won;Kim, Kyoung-Sik;Hahn, Jae-Won
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2006.06a
    • /
    • pp.89-96
    • /
    • 2006
  • In this study, PID control method was applied to decrease the power fluctuation of the pulse laser which is one of the major processing variables in laser machining process. To stabilize the power fluctuation of the pulse laser, we averaged 10 pulse outputs of Nd:YAG laser operating in 10Hz using boxcar averager, and with taking this averaged output as an input signal, we conducted PID control using optical attenuator which is consisted of half wave plate attached on the stepping motor and polarizer. When PID control was not enabled, the power fluctuation was 4.71% and with PID control, the power fluctuation was 1.86% for 2 hours and 1 hour respectively. As a result, we stabilized the power fluctuation of the pulse laser by 60.5%

  • PDF

Interchannel RF Power Fluctuation in WDM-RoF System Employing Photonic Crystal Fiber (광결정 광섬유를 이용한 WDM-RoF 시스템의 채널간 전력변화 편차 분석)

  • Kim, So-Eun;Lee, Chung-Ghiu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.4
    • /
    • pp.821-828
    • /
    • 2012
  • In this paper, we report that the differences between RF power levels can be improved in wavelength division multiplexing - radio over fiber (WDM-RoF) system by using a photonic crystal fiber. In a WDM-RoF system, each WDM channel experiences different received RF power level fluctuation in remote node (RN) because of wavelength-dependent dispersion. Since each WDM channel experiences different power fluctuation, the RF power fluctuation acts as a design constraint in viewpoint of network design. We designed a photonic crystal fiber to improve the effect of wavelength- dependent dispersion on RF power fluctuation. Also, we analyzed the wavelength-dependent difference of inter-channel RF power fluctuations.

Analysis on Characteristic of Pressure Fluctuation in Hydraulic Turbine with Guide Vane

  • Shi, FengXia;Yang, JunHu;Wang, XiaoHui
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.3
    • /
    • pp.237-244
    • /
    • 2016
  • An unsteady three-dimensional simulation based on Reynolds time-averaged governing equation and RNG $k-{\varepsilon}$ turbulence model, was presented for pump-as-turbine, the pressure fluctuation characteristic of hydraulic turbine with guide vane was obtained. The results show that the time domains of pressure fluctuation in volute change periodically and have identical cycles. In volute tongue and inlet pressure fluctuations are light, while in dynamic and static coupling interface pressure fluctuations are serious; In impeller blade region the pressure fluctuation of pressure surface are lighter than that of suction surface. The dominant frequencies of pressure fluctuation concentrate in low frequency region, and concentrate within 2 times of the blade passing frequency.

Research on the Mechanism of Neutral-point Voltage Fluctuation and Capacitor Voltage Balancing Control Strategy of Three-phase Three-level T-type Inverter

  • Yan, Gangui;Duan, Shuangming;Zhao, Shujian;Li, Gen;Wu, Wei;Li, Hongbo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2227-2236
    • /
    • 2017
  • In order to solve the neutral-point voltage fluctuation problem of three-phase three-level T-type inverters (TPTLTIs), the unbalance characteristics of capacitor voltages under different switching states and the mechanism of neutral-point voltage fluctuation are revealed. Based on the mathematical model of a TPTLTI, a feed-forward voltage balancing control strategy of DC-link capacitor voltages error is proposed. The strategy generates a DC bias voltage using a capacitor voltage loop with a proportional integral (PI) controller. The proposed strategy can suppress the neutral-point voltage fluctuation effectively and improve the quality of output currents. The correctness of the theoretical analysis is verified through simulations. An experimental prototype of a TPTLTI based on Digital Signal Processor (DSP) is built. The feasibility and effectiveness of the proposed strategy is verified through experiment. The results from simulations and experiment match very well.

Power Fluctuation Reduction of Pitch-Regulated MW-Class PMSG based WTG System by Controlling Kinetic Energy

  • Howlader, Abdul Motin;Urasaki, Naomitsu;Yona, Atsushi;Senjyu, Tomonobu;Saber, Ahmed Yousuf
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.116-124
    • /
    • 2012
  • Wind is an abundant source of natural energy which can be utilized to generate power. Wind velocity does not remain constant, and as a result the output power of wind turbine generators (WTGs) fluctuates. To reduce the fluctuation, different approaches are already being proposed, such as energy storage devices, electric double layer capacitors, flywheels, and so on. These methods are effective but require a significant extra cost to installation and maintenance. This paper proposes to reduce output power fluctuation by controlling kinetic energy of a WTG system. A MW-class pitch-regulated permanent magnet synchronous generator (PMSG) is introduced to apply a power fluctuation reducing method. The major advantage of this proposed method is that, an additional energy storage system is not required to control the power fluctuation. Additionally, the proposed method can mitigate shaft stress of a WTG system. Which is reflected in an enhanced reliability of the wind turbine. Moreover, the proposed method can be changed to the maximum power point tracking (MPPT) control method by adjusting an averaging time. The proposed power smoothing control is compared with the MPPT control method and verified by using the MATLAB SIMULINK environment.

Robust Fuzzy Controller for Mitigating the Fluctuation of Wind Power Generator in Wind Farm (풍력발전단지의 출력변동저감을 위한 강인 퍼지 제어기 설계)

  • Sung, Hwa Chang;Tak, Myung Hwan;Joo, Young Hoon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.1
    • /
    • pp.34-39
    • /
    • 2013
  • This paper proposes the implementation of robust fuzzy controller for designing intelligent wind farm and mitiagating the fluctuation of wind power generator. The existing researches are limited to individual wind turbine with variable speed so that it is necessary to study the multi-agent wind turbine power system. The scopes of these studies include from the arrangements of each power turbine to the control algorithms for the wind farm. For solving these problems, we introduce the composition of intelligent wind farm and use the T-S (Takagi-Sugeno) fuzzy model which is suitable for designing fuzzy controller. The control object in wind farm enables the minimizing the fluctuation of wind power generator. Simulation results for wind fram which is modelled as mathematically are demonstrated to visualize the feasibility of the proposed method.

An Investigation of the Major Factors Relating to the Flow Fluctuation at a Natural Gas Metering Facility (천연가스 계량설비에서 발생하는 유량 헌팅 현상 원인 분석)

  • An, Seung-Hee;Her, Jae-Young;Jeong, Jong-Tae;Sin, Chang-Hun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.158-165
    • /
    • 2005
  • KOGAS(Korea Gas Corporation) has about a hundred of local stations to supply natural gas to the city gas companies and the power stations. As some severe flow fluctuation phenomena are observed in several governor stations, the investigation about the reasons and factors which are relating to flow fluctuation has been started. Some field surveys hav been carried out and experimental studies have been performed to find the fluctuation mechanism. As a result, it is found that the flow fluctuation is related with the length of straight pipe in front of the meter, the size of the header pipe and the variation of demand at the city gas company and the power station. Furthermore. it is also proved that both the length of the transmitter cable and the status of the coating of signal transmission cable do not affect flow fluctuation, but the measurement range of the differential pressure transmitter influences flow fluctuation. On the other hand, as the averaging the flow fluctuation is converged to less than 0.1 % in almost all of the cases, it is concluded that the quantity of flow fluctuation do not relates to metering accuracy directly.

  • PDF

Study on the Improvement of Output Fluctuation from Generator Driven by Large Size-Low Speed Diesel Engine (대형저속 디젤엔진 구동 발전기의 출력변동 개선에 관한 연구)

  • 김영주;전효중;이돈출;이충기
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.16 no.5
    • /
    • pp.6-16
    • /
    • 1992
  • Since world-wide oil shock on 1970s, many large size-low speed diesel engines, instead of steam turbines, are used for the industrial electric power generating plants due to their economic advantage of low specific fuel consumption. But it is very important to control their electric power fluctuation problems for the purpose of smooth parallel operation with existing power plants. In this paper the fluctuation problem of KEPCO Nam-cheju No.1 generator driven by diesel ngine(B & W 7K 60MC, 13931x138.5RPM) is investigated with analysis of torsional vibration of which 4th harmonic component is related to its power fluctuation. The problem can be improved by modification of cylinder arrangement and flywheel position in reverse sequence, equalizing the combustion gas pressure of all cylinder and installation of torsional vibration damper enlarged 30%(Je=7287Kg.m$^{2}$) and high quality balancing of generator rotor.

  • PDF

Analysis on Required Capacity of Energy Storage System to Mitigate Wind Power Fluctuation (풍력발전기의 출력 안정화를 위한 에너지 저장장치 용량 산정 사례연구)

  • Kang, Min Hyeok;Chae, Sang Heon;Ahn, Jin Hong;Kim, Eel-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.6
    • /
    • pp.59-68
    • /
    • 2017
  • In accordance with the policy of local government, the large scale of wind farms have been installed in Jeju power system. However, The intermittent characteristics of wind power output may cause grid voltage and frequency variation, especially in weak power system. One of the solution to solve this problem is installation of Energy storage system (ESS). In this case, the ESS will regulate the active power generated from wind farm to mitigate fluctuation. Actually, the local government of Jeju island constructed ESS connected to Hangwon wind turbine in 2016. From this point, this paper analyzes requirement capacity of ESS to mitigate wind power fluctuation based on measured data from Hangwon wind turbine and ESS. The simulation results will be carried out by Matlab program.