• Title/Summary/Keyword: Power feedforward

Search Result 248, Processing Time 0.02 seconds

Implementation of Linear Power Amplifier with 1.9 GHz for PCS Basestation (1.9 GHZ PCS 기지국용 선형 전력증폭기의 제작)

  • Kim, Sang-Ki;Bang, Sung-Il
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.88-96
    • /
    • 2003
  • In this paper, We designed and implemented a linear high-power amplifier which can be used for the commercial service in band of $1.9GHz(1.93{\sim}1.99GHz)$ at U.S.A. The output power of the implemented linear high power amplifier is 25W. In order to satisfy IMD characters decided by FCC, the Feedforward linearization techniques has been used. The used feedforward method has improved the IMD characteristics from 10.51dBc to 19.01dBc in each power level from 1W(30dBm) to 25W(44dBm). The IMD level of the final output shows from minimum 64.84dBc to maximum 68.17dBc. Because this good characteristics of IMD, the LPA is expected to use as a commercial product of PCS base station.

  • PDF

A Study on the Speed Control of BLDC Motor Using the Feedforward Compensation (전향보상을 이용한 BLDC 전동기의 속도제어에 관한 연구)

  • 박기홍;김태성;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.3
    • /
    • pp.253-259
    • /
    • 2004
  • This paper presents a speed controller method based on the disturbance torque observer for high-performance speed control of the brushless DC (RLDC) motor. In case of the speed control of robot arms and tracking applications with lower stiffness, we cannot design the speed controller gain to be very large from the viewpoint of the system stability Thus, the feedforward compensation method using disturbance torque observer was proposed. This method can improve the speed characteristic without increasing the speed controller gain. The speed characteristic against disturbance torque can be improved when the bandwidth of the speed controller cannot be made large enough. Consequently, the speed control of the BLDC motor for the high-performance application become achieved.

Characteristic Analysis and Control of Three Phase PWM Buck AC-AC Converter (3상 PWM Buck AC-AC 컨버터의 특성해석과 제어)

  • 최남섭
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.6
    • /
    • pp.1283-1290
    • /
    • 2003
  • Recently, PWM Buck AC-AC Converter is widely employed in various industrial applications such as voltage and power regulator, electronic transformer, phase shifter and so on. This paper presents static and dynamic modeling and complete characteristic analysis of a PWM Buck AC-AC converter. Firstly, the three phase converter system is modelled by using DQ transformation whereby we can obtain basic characteristic equations such as voltage gain and power factor as well as state equation and transfer function for control. Secondly, based on the analysis, the feedforward-feedback control technique is also proposed to obtain instantaneous duty level change whereby very fast dynamic response is achieved. Finally, the experimental results show the validity of the modeling, analysis and control.

A Study on DC-DC Power Supply for Magnetically Levitated Vehicle (자기부상열차용 DC-DC 전원장치에 관한 연구)

  • Chun, Choon-Byeon;Jeon, Kee-Young;Lee, Hoon-Goo;Han, Kyung-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.128-135
    • /
    • 2004
  • The author present a modified multi-loop algorithm including feedforward for controlling a 55kW step down chopper in the power supply of Maglev. The control law for the duty cycle consists of three terms. The first is the feedforward term. which compensates for variations in the input voltaga. The second term consists of the difference between the slowly moving inductor current and output current. The third term consists of proportional and integral terms involving the perturbation in the output voltage. This perturvation is derived by subtracting the desired output voltage from the actual output voltage. The proportional and integral action stabilizes the system and minimizes output voltage error. In order to verify the validity of the proposed multi-loop controller, simulation study was tried using Matlab simulink

Design and Implementation of a Linearizer Using the Feedforward Loop without Delay Lines (지연 선로가 없는 Feedforward Loop를 이용한 선형화기의 설계 및 제작)

  • 정승환;조경준;김완종;안창엽;김종헌
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.116-123
    • /
    • 2000
  • This paper presents a linearizer using the feedforward loop which can be applied to PCS base-station applications. This linearizer used a IM amplifier and an auxiliary amplifier in order to remove delay lines used in the predistortor using the feedforward technique. The delay line in error loop is changed by the main power amplifier(PA) and the error amplifier is utilized to amplify the error signal which fed to the output of main amplifier. The linearizer was simulated by HP ADS ver 1.1 and fabricated on GML 1000 with thickness of 0.8 mm and dielectric constant of 3.2. Two-tone signals at 1.85 GHz and 1.851 GHz with -7dBm/tone from synthesizers are injected into the main PA. The main PA with a 27 dB gain and a $P_{1dB}$ of 29 dBm(two-tone) was utilized. The reduction of intermodulation distortion (IMD) is around 17 dB.

  • PDF

Enhancement of ACPR and Noise level of Analog Optical Transmitter by Feedforward Compensation (피드포워드 보상회로를 적용한 아날로그 광 송신기의 ACPR과 잡음 레벨 개선)

  • Lee, Joon-Jae;Park, Sang-Hyun;Yun, Young-Seol;Choi, Young-Wan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2005.08a
    • /
    • pp.149-153
    • /
    • 2005
  • The optical fiber micro-cellular system requires the high linearity that determines the quality and capacity of system. Hence, there is a need for improving the linearity in mobile communication system. In order to compensate dispersion-induced signal distortion, we fabricated the optical feedforward transmitter. The compared 3rd-IMD was enhanced by 38 dB for two-tone case and the Adjacent Channel Power Ratio was enhanced by 20 dB for W-CDMA 1 carrier and by 16 dB for W-CDMA 3 carriers. Also, the induced noise level was reduced.

  • PDF

Design of Adaptive GPC wi th Feedforward for Steam Generator (증기발생기 수위제어를 위한 적응일반형예측제어 설계)

  • Kim, Chang-Hwoi
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.261-264
    • /
    • 1993
  • This paper proposes an adaptive generalized predictive control with feedforward algorithm for steam generator level control in nuclear power plant. The proposed algorithm is shown that the parameters of N-step ahead predictors can be obtained using the parameters of one-step ahead predictor which is derived from plant model with feedforward. Using this property the proposed scheme is an adaptive algorithm which consists of GPC method and the recursive least squares algorithm for identifying the parameters of one-step ahead predictor. Also, computer simulations are performed to evaluate the performance of proposed algorithm using a mathematical model of PWR steam generator Simulation results show good performances for load variation. And the proposed algorithm shows better responses than PI controller does.

  • PDF

The Improvement of Transient State Characteristics with Voltage Type PWM Conbverter Control (전압형 PWM 컨버터 제어에의한 과도상태의 특성 개선)

  • 이상일;이진섭;백형래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.3
    • /
    • pp.268-274
    • /
    • 1999
  • The problem of power factor and hmmonics are occurred in convelter system which used to SCRs and diodes as p power semiconductor devices. IGBT power device with selh:ommutation type was solved that problem. maintain the l input line current with sinusoidal wave CUlTent of input power source voltage. It was estimated that improvement of t transient state characteristics with feedfolward compensator added in the diode rectifier with single phase voltage type i inverter was used to simulation load. As a results it was verified that the transient state characteristics with voltage t type PWM convelter control was improved.

  • PDF

A 67dB DR, 1.2-V, $0.18-{\mu}m$ Sigma-Delta Modulator for WCDMA Application (WCDMA용 67-dB DR, 1.2-V, $0.18-{\mu}m$ 시그마-델타 모듈레이터 설계)

  • Kim, Hyun-Jong;Yoo, Chang-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.6 s.360
    • /
    • pp.50-59
    • /
    • 2007
  • [ $0.18-{\mu}m$ ] CMOS 1.2-V 2nd-order ${\Sigma}{\Delta}$ modulator with full-feedforward topology is designed. Using full-feedforward topology makes op-amp performance requirements much less stringent, therefore it has been adopted as a good candidate for low-voltage low-power applications throughout the world. Also, ${\Sigma}{\Delta}$ modulator is designed with top-down design approach, therefore various nonideal effects of op-amp are modeled in this paper.

Development of Knee Ankle Foot Orthosis for Gait Rehabilitation Training using Plantaflexion and Knee Extension Torque (족저굴곡과 무릎 신전 토크를 이용한 보행 재활 훈련용 장하지 보조기 개발)

  • Kim, Kyung;Kim, Jae-Jun;Heo, Min;Jeong, Gu-Young;Ko, Myoung-Hwan;Kwon, Tae-Kyu
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.10
    • /
    • pp.948-956
    • /
    • 2010
  • The purpose of this study was to test the effectiveness of a prototype KAFO (Knee-Ankle-Foot Orthosis) powered by two artificial pneumatic muscles during walking. We had previously built powered AFO (Ankle-Foot Orthosis) and KO (Knee Orthosis) and used it effectively in studies on assistance of plantaflexion and knee extension motion. Extending the previous study to a KAFO presented additional challenges related to the assistance of gait motion for rehabilitation training. Five healthy males were performed gait motion on treadmill wearing KAFO equipped with artificial pneumatic muscles to power ankle plantaflexion and knee extension. Subjects walked on treadmill at 1.5 km/h under four conditions without extensive practice: 1) without wearing KAFO, 2) wearing KAFO with artificial muscles turned off, 3) wearing KAFO powered only in plantaflexion under feedforward control, and 4) wearing KAFO powered both in plantaflexion and knee extension under feedforward control. We collected surface electromyography, foot pressure and kinematics of ankle and knee joint. The experimental result showed that a muscular strength of wearing KAFO powered plnatarfexion and knee extension under feedforward control was measured to be lower due to pneumatic assistance and foot pressure of wearing KAFO powered plnatarfexion and knee extension under feedforward control was measured to be greater due to power assistance. In the result of motion analysis, the ankle angle of powered KAFO in terminal stance phase was found a peak value toward plantaflexion and there were difference of maximum knee flexion range among condition 2, 3 and 4 in mid-swing phase. The current orthosis design provided plantaflexion torque of ankle jonit in terminal stance phase and knee extension torque of knee joint in mid-swing phase.