• Title/Summary/Keyword: Power distribution facilities

Search Result 280, Processing Time 0.038 seconds

Distributed Energy System Connection Limit Capacity Increase Technology Using System Flexible Resources (계통유연자원을 활용한 분산에너지 계통접속 한계용량 증대 기술)

  • Jeong Min Park
    • Journal of Integrative Natural Science
    • /
    • v.16 no.4
    • /
    • pp.139-145
    • /
    • 2023
  • Due to changes in the distribution system and increased demand for renewable energy, interest in technology to increase the limit capacity of distributed energy grid connection using grid flexible resources is also increasing. Recently, the distribution system system is changing due to the increase in distributed power from renewable energy, and as a result, problems with the limited capacity of the distribution system, such as waiting for renewable energy to connect and increased overload, are occurring. According to the power generation facility status report provided by the Korea Power Exchange, of the total power generation capacity of 134,020 MW as of 2021, power generation capacity through new and renewable energy facilities is 24,855 MW, accounting for approximately 19%, and among them, power generation through solar power accounts for a total portion of the total. It was analyzed that the proportion of solar power generation facilities was high, accounting for 75%. In the future, the proportion of new and renewable energy power generation facilities is expected to increase, and accordingly, an efficient operation plan for the distribution system is needed. Advanced country-type NWAs that can integrate the operation and management of load characteristics for each line of the distribution system, power distribution, regional characteristics, and economic feasibility of distributed power in order to improve distribution network use efficiency without expanding distribution facilities due to the expansion of renewable energy. An integrated operating system is needed. In this study, in order to improve the efficiency of distribution network use without expanding distribution facilities due to the expansion of renewable energy, we developed a method that can integrate the operation and management of load characteristics for each line of the distribution system, power distribution, regional characteristics, and economic feasibility of distributed power. We want to develop an integrated operation system for NWAs similar to that of advanced countries.

Detection and Diagnosis of Power Distribution Supply Facilities Using Thermal Images (열화상 이미지를 이용한 배전 설비 검출 및 진단)

  • Kim, Joo-Sik;Choi, Kyu-Nam;Lee, Hyung-Geun;Kang, Sung-Woo
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • Maintenance of power distribution facilities is a significant subject in the power supplies. Fault caused by deterioration in power distribution facilities may damage the entire power distribution system. However, current methods of diagnosing power distribution facilities have been manually diagnosed by the human inspector, resulting in continuous pole accidents. In order to improve the existing diagnostic methods, a thermal image analysis model is proposed in this work. Using a thermal image technique in diagnosis field is emerging in the various engineering field due to its non-contact, safe, and highly reliable energy detection technology. Deep learning object detection algorithms are trained with thermal images of a power distribution facility in order to automatically analyze its irregular energy status, hereby efficiently preventing fault of the system. The detected object is diagnosed through a thermal intensity area analysis. The proposed model in this work resulted 82% of accuracy of detecting an actual distribution system by analyzing more than 16,000 images of its thermal images.

Evaluation Methodology of System Interruption Cost Taking into Consideration Failure Rate of Distribution Facilities (배전기자재별 고장확률을 고려한 배편계통 수용가 정전비용 산출 기법)

  • Choe, Sang-Bong;Kim, Dae-Gyeong;Jeong, Seong-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.5
    • /
    • pp.232-237
    • /
    • 2002
  • It is increased for methodology to evaluate distribution power system interruption cost in power supply zones under competitive electricity market. This paper presents algorithms to evaluate system interruption cost in distribution power supply zones taking into consideration failure rate of distribution facilities and composite customer interruption cost. In this paper, it is introduced for weighting factor for each customer failure duration and failure rate of distribution facilities to evaluate reasonable system interruption cost in distribution power supply area. Also, this Paper estimates evaluation results of system interruption cost using a sample model system. Finally, evaluation results of system interruption cost based on failure rate of distribution facilities and composite customer interruption cost are shown in detail.

A Study on the Web-based Overall Information Management System Developement of the Overhead Distribution Facilities Using SIAS (SIAS를 이용한 웹 기반 가동배전설비 종합 정보관리 시스템 개발에 관한 연구)

  • Lee, Dong-Yeop;Kim, Dong-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.898-904
    • /
    • 2009
  • The objective of the present study lies in constructing web-based GIS system providing broad range of information applicable for power/telecommunications distribution facilities through cable. Nowadays, Korea is renowned forits faste sttele communications network across the nation enjoyable for being a test-runbed by worldwide contents providers. It is not too much to say that the trend is caused by the fact that Korea utilizes the cobweb-like power transmission cables applicable for the nationwide telecommunications networking. In particular, the trend has been all the more encouraged by the governmental drive to expedite the telecommunication network by way of the established power transmission facilities deemed as publicutility. Nevertheless, few can deny that the overexcessive competition among telecommunication service providers increasingly gives rise to unauthorized, arbitrary facilitation of distribution devices, which becomes much burden in operating the normal power/telecommunications distribution facilities by a power-generating company. In this regard, the study, to cope with such problems, attempts to develop a web GIS-based information management system compatible with NDIS(New Distribution Information System), a distribution facility management system now under operation by KEPCO, making advantage of GE Energy's SIAS(Smallworld Internet Application) technology. The model provided by this study is expected to get closer into effective operation of distribution facilities along with better sharing of information among conventional telecommunications operators, while getting rid of infringed facilitation cases

Researches on The Aging Characteristics in Distribution Facilities (배전용(配電用) 기자재(機資材)의 열화특성(劣化特性) 고찰(考察))

  • Jang, Jeong-Tae;Koh, In-Seok;Hong, Soon-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.81-85
    • /
    • 1991
  • The distribution facilities fault has been anually shown about 13% all of the total distribution faults. Therefore, to prevent, the distribution facilities we have to manage them properly during their life time and enhance their quality and advance preventible maintenance, that is predictive maintenance or condition based maintenance. This paper presents the aging characteristics and the degenerating factors. Accordingly, improving the enhanced quality of distribution facilites is expected to contribute the electric power operation constantly.

  • PDF

The study of technical trend of Chinese distribution automation (중국의 배전자동화 기술동향 분석)

  • Ha, Bok-Nam;Seol, Ieel-Ho;Jung, Mi-Ae;Shin, Ick-Su;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.430-432
    • /
    • 2003
  • We want to know the specification of Chinese distribution automation system and facilities for approach to Chinese market. This paper introduces the purpose of distribution automation project, function of distribution automation system, standard of facilities by specification of utility in China.

  • PDF

A Diagnostic Technique for Power Distribution Line Facilities by the Corona Detector (코로나 검출기를 이용한 배전설비 진단기법)

  • Cho, Yong-Sang;Song, Gyu-So;Choi, Yu-Seong;Park, Tae-Seong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.588-593
    • /
    • 2011
  • The airpollutant may accelerate degradation of power line facilities, and may reduce the life of the electric facilities. In case of korea, there are a tendency that the density of air pollution may be increased by industrial development. while lack of research activity and establishment of a countermeasure on this issue. Recently the occurrence of electricity failure have been reduced on the power transmission and distribution lines. but the occurrence of electricity failure by insulator itself has been increased. It means that we should have develop more clear technique for detection of the wrong insulator. In this study to provide a method for detection of the insulator failure or effective management of the troubled insulator, we analyze the chemical composition of the insulator which used on power distribution line at the sea side locations. To define the relation between insulation and corona intensity, we design and develop an corona detector. We define the variation of insulation by pollution changes on the insulator and verify quantitative relation between corona and insulations using the corona detector.

An Investigation on the Air Pollution for Distribution Facilities In Metropolitan Area (22.9kV-Y 배전설비에 부착된 대도시 대기오염성분에 대한 조사연구)

  • Kim, Dong-Myung;Yoon, Tae-Sang;Park, Sang-Man;Yi, Sue-Muk
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1548-1550
    • /
    • 2000
  • The effect of air pollution on the distribution facilities was investigated. In order to evaluate the pollution level in the metropolitan area, contaminated specimens were analyzed with various technique such as ICP-AES, EA, and so on. The contaminants on the surface of the distribution line or insulators were combined with approximately 10 percent of organic and 90 percent of inorganic materials. We found out that the electric facilities were affected by the contaminants on the surface of the facilities.

  • PDF

Development of intelligent distribution automation system with the function of substation SCADA, power quality monitoring and diagnosis condition monitoring (SCADA 기능과 전기품질 온라인 감시 및 배전설비 열화감시 기능을 갖는 배전지능화 시스템 개발)

  • Ha, B.N.;Lee, S.W.;Shin, C.H.;Seo, I.Y.;Jang, Mun-Jong;Park, M.H.;Yun, G.G.;Song, I.K.;Lee, B.S.;Lee, J.C.;NamKoong, W.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1776-1786
    • /
    • 2010
  • Intelligent distribution automation system have total monitoring and control capability. The system covers substation, distribution network, distributed generations and customers at HV system. Various intelligent distribution facilities installed at distribution systems have voltage sensor, current sensor, aging monitoring sensor. Intelligent Feeder Remote Terminal Unit (IFRTU) tied to intelligent distribution facilities process information from facilities and it checks information of fault, power quality and aging of distribution facilities. The information is transmitted to master station through communication line. The master station have remote monitoring system covers substation, distribution network, distributed generations and customers. It also have various application programs that maintain optimal network operation by using information from on-site devices.

Deterioration Diagnostic Techniques for Power Facilities by Analyzing Pulse-Height of leakage current (누설전류 파고분석에 의한 전력설비의 열화진단 기술)

  • 한주섭;김명진;손원진;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.367-370
    • /
    • 2001
  • This paper proposes a new deterioration diagnostic technique for power facilities by analyzing the pulse-height analysis of leakage current. Until now, various deterioration diagnostic techniques to prevent power system failures by deterioration of power facilities are suggested, and most of which measures leakage current amplitude only as a estimation parameter. In this experiment, it is known that the pulse heights of the leakage current are increased according to deterioration progress as well as there comes remarkable changes in pulse height distribution thereto. Therefore, the use of pulse height distribution in deterioration diagnostic technique makes more accurate diagnosis than the conventional method by using only leakage current value. From the application test, it is confirmed that the proposed technique has sufficient performance to diagnose deterioration of power facilities.

  • PDF