• 제목/요약/키워드: Power conditioning system

검색결과 814건 처리시간 0.037초

대용량 연료전지 발전시스템용 전력변환기 개발 (Development of Power Conditioning System for High Power Fuel Cell System)

  • 강호현;이진희;백승택;정홍주;정준모;서인영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.153-156
    • /
    • 2007
  • This paper presents the design, development and performance of a power conditioning system (PCS) for application to a 250kW Molten Carbonate Fuel Cell (MCFC) generation system. A DSP controller was used to control the dc-dc and dc-ac converter operation for grid connection and power injection to the grid. The controller must also supervise the total PCS operation while communicating with the fuel cell system controller. A control method for parallel operation of dc-dc converters was proposed and verified. A 250kW prototype was successfully built and tested. Experimental performances are compared to minimum target requirements of the PCS for MCFC.

  • PDF

증기-액 이젝터를 적용한 해양온도차발전 시스템의 성능 특성 (Performance Characteristics of OTEC(Ocean Thermal Energy Conversion) Power Cycle with Vapor-Liquid Ejector)

  • 윤정인;손창효;김현욱;하수정;이호생;김현주
    • 동력기계공학회지
    • /
    • 제18권5호
    • /
    • pp.88-93
    • /
    • 2014
  • In this paper, the performance analysis of condensation and evaporation capacity, turbine work and efficiency of the OTEC power system using vapor-liquid Ejector is presented to offer the basic design data for the operating parameters of the system. The working fluid used in this system is $CO_2$. The operating parameters considered in this study include the vapor quality at heat exchanger outlet, pressure ratio of ejector and inlet pressure of low turbine, mass flow ratio of separator at condenser outlet. The main results were summarized as follows. The efficiency of the OTEC power cycle has an enormous effect on the mass flow ratio of separator at condenser outlet. With a thorough grasp of these effects, it is possible to design the OTEC power cycle proposed in this study.

2단 구성 DC-DC 컨버터와 인버터에 의한 연료전지발전 계통연계시스템 연구 (Study on Power Conditioning System for Fuel Cell Power Generation with 2-Stage DC-DC Converter and Inverter)

  • 주영아;오은태;한병문;이준영
    • 전기학회논문지
    • /
    • 제58권8호
    • /
    • pp.1551-1558
    • /
    • 2009
  • This paper proposes a new power conditioning system for the fuel cell power generation, which consists of a LLC resonant DC-DC converter and 3-phase inverter. The LLC resonant converter boosts the fuel cell voltage of 26-48V up to 400V, using the hard-switching boost converter and the high-frequency ZVS half-bridge converter. The operation of proposed power conditioning system was verified through simulations with PSCAD/EMTDC software. The feasibility of hardware implementation was verified through experimental works with a laboratory prototype, which was built with 1.2kW PEM fuel-cell stack, 1kW LLC resonant converter, and 3kW PWM inverter. The proposed system can be utilized to commercialize a real interconnection system for the fuel-cell power generation.

A Study of Islanding Detection of Grid-connected Three-phase Photovoltaic Power Conditioning System

  • Jung Y.S.;Yu G.J.;Choi J.Y.;Choi J.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.761-764
    • /
    • 2003
  • Islanding phenomenon of a grid-connected photovoltaic (PV) power conditioning system (PCS) is said to occur if the PCS continues to power a section of the utility system after that section has been disconnected from the utility source. Since islanding creates hazards for personnel and equipment, PCSs are required to detect and prevent Et. In this paper, several islanding detection methods (IDMs) and reactive power variation method are described. Islanding test results for 9kW PCS are presented for verification.

  • PDF

전력변환 시스템의 실시간 스위치 고장진단에 대한 연구 (A Study on the Real-Time Switch Fault Diagnosis of the Power conditioning System)

  • 이용식;이선우;김재현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1066-1067
    • /
    • 2015
  • This paper presents a diagnosis method for the detection and location of open-short switch faults in the three-phase power conditioning system. A method for switch fault diagnosis on the power conditioning system is proposed, based on the concordia transform. The switch fault types and locations on power conditioning system are diagnosed by a method in which analyze the d-q current vector locus and current pattern. The Simulation results confirm the proposed diagnostic method.

  • PDF

독립형 태양광 발전을 이용한 효율적인 하이브리드 LED 가로등 조명관리 시스템 설계 (An Efficient Hybrid LED Street Lighting Management System Design using Standalone Solar Photovoltaic)

  • 홍성일;인치호
    • 제어로봇시스템학회논문지
    • /
    • 제20권9호
    • /
    • pp.984-993
    • /
    • 2014
  • In this paper, we propose a design for an efficient hybrid LED street lighting management system using standalone solar photovoltaic. The proposed efficient hybrid LED street lighting management system was composed of hybrid power conditioning system, gateways, LED street lights and a monitoring server. The hybrid power conditioning system was designed to charge produced power by solar photovoltaic panels in day time, and supply power to the LED street lights in night time. If there is insufficient power, the system was designed to operate using firm power, because the system utilizes photovoltaic power. A system control algorithm allied to the lighting management system, and experimented by being configured to the functions that are able to perform real-time monitoring and remote control through the lighting management system even when absent. In the result of the efficiency analysis of the hybrid lighting management system proposed in this paper, we were able to increase the energy efficiency compared to existing lighting control systems by reducing power consumption and electricity costs.

고주파링크 전력계통 연계형 PCS (High Frequency Link PCS for Interfacing with Power Utility System)

  • 정봉근;윤광호;이광호;김은수;차인수
    • 전력전자학회논문지
    • /
    • 제15권1호
    • /
    • pp.60-68
    • /
    • 2010
  • 최근 PCS(Power Conditioning System)는 고효율, 고 전력밀도 및 고 기능화를 통해 고집적화 추세에 있다. 이러한 요구를 만족시키기 위해 LLC 공진인버터와 LF 사이클로 컨버터로 구성된 회로를 제안했다. 동작분석 및 1kW 시제품을 제작하여 110Vac, 60Hz 전원계통연계실험 통해 적용 가능함을 보였으며 이에 대한 실험결과를 서술하였다.

태양광 발전 시스템에서의 벅 컨버터 모델링과 해석 (Modeling and Analysis of The Buck Converter in Photovoltaic Power Conditioning System)

  • 정승환;최익;최주엽
    • 한국전자통신학회논문지
    • /
    • 제8권7호
    • /
    • pp.1039-1048
    • /
    • 2013
  • 일반적으로 벅 컨버터 제어기는 컨버터의 출력 전압을 제어하도록 설계하지만, 태양광발전시스템에서의 벅 컨버터 제어기는 설계 방식을 달리 구분해야 한다. 본 논문에서는 MPPT(Maximum Power Point Tracking)을 위하여 벅 컨버터의 입력 전압(태양광전지의 출력 전압)을 제어한다고 가정하였다. 또한, 컨버터의 입력 전압을 제어하기 위한 새로운 벅 컨버터 모델을 제시한다. 이 컨버터 모델은 최대전력점(MPP)에서 동작점을 두어 선형화한 태양광전지의 모델을 포함하며, 모델의 타당성을 검증하기 위하여 대신호와 소신호로 나누어 분석한다. 또한 일반적인 선형제어기를 설계하였을 때, 제어 가능성을 분석하여 검증한다.

스마트 그리드를 위한 분산자원과 전력변환장치 기반 마이크로그리드 독립운전 (Microgrid Island Operation Based on Power Conditioning System with Distributed Energy Resources for Smart Grid)

  • 허세완;박완기;이일우
    • 한국통신학회논문지
    • /
    • 제42권5호
    • /
    • pp.1093-1101
    • /
    • 2017
  • 스마트 그리드를 구성하는 기본 단위 요소인 마이크로그리드(Microgrid)는 전력의 중앙 공급방식에서 벗어나 독립된 하나의 체계를 이룬다. 본 논문은 전력변환장치(Power Conditioning System)를 기반으로 마이크로그리드를 계통으로부터 전기적으로 독립시키고, 신재생 에너지원과 에너지 저장장치(Energy Storage System) 등의 분산자원(Distributed Energy Resource)을 활용하여 효과적으로 독립 상태를 유지하고 운영할 수 있는 방법을 제안한다. 계통의 위상검출과 동기화를 통해 계통에 연계하거나 독립 시에 부하에 미치는 영향을 최소화할 뿐만 아니라 계통의 정전 상황에서도 안정적으로 운영이 가능하다.

New MPPT Control Strategy for Two-Stage Grid-Connected Photovoltaic Power Conditioning System

  • Bae, Hyun-Su;Park, Joung-Hu;Cho, Bo-Hyung;Yu, Gwon-Jong
    • Journal of Power Electronics
    • /
    • 제7권2호
    • /
    • pp.174-180
    • /
    • 2007
  • In this paper, a simple control method for two-stage utility grid-connected photovoltaic power conditioning systems (PCS) is proposed. This approach enables maximum power point (MPP) tracking control with post-stage inverter current information instead of calculating solar array power, which significantly simplifies the controller and the sensor. Furthermore, there is no feedback loop in the pre-stage converter to control the solar array voltage or current because the MPP tracker drives the converter switch duty cycle. This simple PCS control strategy can reduce the cost and size, and can be utilized with a low cost digital processor. For verification of the proposed control strategy, a 2.5kW two-stage photovoltaic grid-connected PCS hardware which consists of a boost converter cascaded with a single-phase inverter was built and tested.