• 제목/요약/키워드: Power burden

검색결과 344건 처리시간 0.03초

재폐로 동작에 따른 초전도 한류기의 회복성능 분석 (Analysis of the Recovery Behavior of SFCL According to Reclosing Operation)

  • 하경훈;조용선;김덕구;최효상
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1073-1077
    • /
    • 2011
  • The breaking capacity of circuit breakers could be no more increased in the electric power system. This is because the fault current increases due to continuous increases in electric power demand and facilities. To solve the problem, it is necessary to come up with an alternative. The superconducting fault current limiter (SFCL) has received an attention among various alternatives. The SFCL effectively reduce a fault current in cooperation with a power circuit breaker. A various types of the SFCL are suggested and a study on them have been progressed. As a result of it, the SFCL can be applyed to the electric power system in the near future. But, a study on recovery behaviors of the SFCL is not enough for applying to the electric power system. If the superconducting elements do not completely recover to the superconducting state after fault operation, it might be a breakdown of the superconducting elements due to heavy power burden and it gives an bad influence on the working of other electric devices. Additionally, the distribution power system has reclosing operation such as open-0.3sec-closed/open-3min-closed/open procedure. So we need to study more about improvement of the recovery behaviors of the SFCL. In this paper, we analyzed the recovery behaviors of a flux-coupling type SFCL according to reclosing operation when a single line-to-ground fault occurred and we compared recovery behaviors of the SFCL with and without a neutral line between secondary reactors and superconducting elements. Also, the flux-coupling type SFCL has advantageous for increases of capacity by controlling the variation in turn ratios between two reactors. Consequently, when the number of turns of the secondary reactors increased, the power burden of the superconducting elements was bigger due to the increase of impedances of the secondary reactors. To distribute the power burden, two superconducting elements connected in series and the balanced quenching of the superconducting elements was induced by connecting a neutral line.

암 환자 돌봄제공자의 돌봄부담감과 대처방식이 소진에 미치는 영향 (Influence of Caring Burden and the Way of Coping on Burnout in Caregivers of Cancer Patients)

  • 허수빈;신소영
    • 한국직업건강간호학회지
    • /
    • 제28권2호
    • /
    • pp.114-123
    • /
    • 2019
  • Purpose: The aims of this study were to identify the effects of caring burden and the way of coping on burnout in caregivers of cancer patients. Methods: One-hundred and forty family caregivers of cancer patients who visited the cancer center at one tertiary hospital in metropolitan city B were included. The data collection was conducted from August 1st to October 1st, 2018, using a structured, self-reported questionnaire. The collected data were analyzed using descriptive statistics, t-test, one-way ANOVA, Pearson correlation coefficients, and multiple regression. Results: In the multiple regression analysis, the subject's gender (${\beta}=.12$, p=.028) and caring burden (${\beta}=.74$, p<.001) had a significant effect on burnout. The explanatory power of the subject's gender, education level, religion, caring time, number of family caregivers, monthly income, economic burden, expectation for treatment, caring burden, the way of aggressive coping, and the way of passive coping with burnout was 63.8% (F=23.28, p<.001). Conclusion: Reducing the caring burden in family caregivers of cancer patients will ultimately contribute to reducing burnout, thereby contributing to an improvement in the psychological well-being and quality of life of family members, as well as positively contributing to the recovery of patients.

3상 변압기의 권수비에 따른 초전도 한류기의 전력특성 (Electric Power Characteristics of a SFCL based on Turn-ratio of 3-Phase Transformer)

  • 정인성;최효상;정병익
    • 전기학회논문지
    • /
    • 제63권3호
    • /
    • pp.414-417
    • /
    • 2014
  • At present, the demand for electric power increases, the electric power system is complicated. The size of the line-to-ground fault and the line-to-line fault occurred with complication of electric power system continue to increase, therefore several issues are raised. To address these issues effectively, the superconducting fault current limiter (SFCL) has been proposed, this study is ongoing. In this paper, we applied the SFCL in three-phase transformer and comparative analysis of the electric power burden to the SFCL. The superconductor is combined to the third winding of transformers in connection structure. In case of a third line-to-line fault, we did comparative analysis of the electric power burden to the SFCL based on the turn ratio of transformer third winding. In this case, we could confirm as the third turn ratio increased, electric power impressed to the superconducting element increased.

Analysis on operation characteristics and power burdens of the double quench trigger type SFCLs

  • Lim, Seung-Taek;Lim, Sung-Hun;Han, Tae-Hee
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제19권2호
    • /
    • pp.33-37
    • /
    • 2017
  • To protect the power systems from fault current, the rated protective equipment should be installed. However growth of power system scale and concentration of loads caused the large fault current in power transmission system and distribution system. The capacities of installed protective equipment have been exceeded the due to increase of fault current. This increase is not temporary phenomenon but will be steadily as long as the industry develops. The power system operator need a counter-measurement for safety, so superconducting fault current limiter (SFCL) has been received attention as effective solutions to reduce the fault current. For the above reasons various type SFCLs have been studied recently. In this paper, operation characteristics and power burden of trigger type SFCL is studied. The trigger type SFCL has been used for real system research in many countries. Another trigger type SFCL (double quench trigger type SFCL) is also studied. For this paper, short circuit test is performed.

요양시설 입소 노인 주보호자에 대한 사회적 지지가 부양긍정감과 부양부담에 미치는 영향 (Effects of Social Support for Elderly Residents' Primary Caregivers in Long-Term Care Facilities on Caregivers' Positive Feelings and Burden)

  • 김지향;한숙정
    • 가정간호학회지
    • /
    • 제26권2호
    • /
    • pp.199-209
    • /
    • 2019
  • Purpose: This study was conducted to determine factors affecting the positive feelings and care burden of elderly residents' primary caregivers in long-term care facilities. Methods: The survey was conducted between November and December 2018. A structured questionnaire was used to collect data, and 148 individuals voluntarily participated. The collected data were examined through descriptive statistical analysis using SPSS WIN ver.24.0, t-test, one-way Anova $Scheff{\acute{e}}$ test, Pearson's correlation coefficient, and multiple regression. Results: Factors that significantly affected caregivers' positive feelings included caregivers' education level(${\beta}=-.32$, p<.001), social support(${\beta}=.31$, p<.001), care burden(${\beta}=-.29$, p=.001), and total support fee(not more than 1.5million won)(${\beta}=-.18$, p=.012). The explanation power was as high as 40.0%(Adj $R^2=.40$). Factors that significantly affected caregivers' burden included social support(${\beta}=-.25$, p=.002), positive feelings(${\beta}=-.25$, p=.002), elderly individual's religion(${\beta}=-.17$, p=.007), and elderly individual's marriage status(${\beta}=.17$, p=.021). The explanation power was as high as 45.0%(Adj $R^2=.45$). Conclusion: Our results suggest that it is necessary to increase social support for elderly residents' primary caregivers in long-term care facilities. This can be helpful to decrease burden and enhance positive feelings in caregivers. We should also collect caregivers' information as well to provide appropriate assistance.

변압기형 초전도 한류기의 퀜치특성에 대한 중성선의 영향 (Influence of a Neutral Line on the Quench Behaviors of a Transformer Type SFCL)

  • 조용선;최효상;구경완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2212-2213
    • /
    • 2008
  • In this paper, we studied the method for simultaneous quenching of a transformer type superconducting fault current limiter (SFCL) with two superconducting elements connected in series. Only an element between two elements of the transformer type SFCL was quenched like the case of the resistive type SFCL. By this quenching characteristics, the power burden of the superconducting element was increased. In order to solve this problem, we connected the neutral line between two superconducting elements and the center of secondary coils. The two elements were all quenched in the transformer type SFCL with a neutral line. As a result, the power burden of superconducting elements was decreased, so it was efficient for the increase of power capacity of the transformer type SFCL.

  • PDF

교육용 웹 기반 전력조류계산 프로그램 개발 (Development of Educational Web-Based Power Flow Program)

  • 양광민;이기송;이정규;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.432-434
    • /
    • 2003
  • This paper developed the web based power flow program for education. Since a lot of users can connect and implement the web based program, the only one computer can get much evaluation burden not to compute. Using the XML technology, which supports the distributed computing technology, we have developed the web-based power flow software and system that are distributed the above calculation burden to three computers: web server, database server, application server. Also, this software was developed to get the difference of number of iteration and evaluation speed as veil as the results of state variables for each node according to the each calculation method for power flow using the chart. Therefore, users can get the physical concept of power flow in addition to the difference among the evaluation methods for power flow. We have performed the case studies with IEEE 14 bus system using the developed software.

  • PDF

YBCO소자의 연결방법에 의한 자속구속형 초전도 한류기의 퀜치특성의 향상 (Improvement of Quench Properties of a Flux-Lock Type Superconducting Fault Current Limiter by the Connection Method of YBCO Elements)

  • 정수복;박형민;최효상
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.323-327
    • /
    • 2008
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) depending on the methods of the serial and parallel connections between the superconducting elements. The flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil through an iron core, and the secondary coil is connected to the superconducting elements in series and parallel. In this paper, the analyses of voltage, current, and resistance of the superconducting elements connected in serial and parallel were performed to increase the power capacity of the flux-lock type SFCL. A part of the superconducting elements was not quenched in $2{\times}2$ serial connection between the elements and then the power burden of the quenched elements was increased. However the elements with $2{\times}2$ parallel connection was all quenched. This means that the power burden of each superconducting element can be reduced under the same conditions. We found that $2{\times}2$ parallel connection was more profitable for the current limiting effects and the increase of the power capacity.

MANAGING SPENT NUCLEAR FUEL FROM NONPROLIFERATION, SECURITY AND ENVIRONMENTAL PERSPECTIVES

  • Choi, Jor-Shan
    • Nuclear Engineering and Technology
    • /
    • 제42권3호
    • /
    • pp.231-236
    • /
    • 2010
  • The growth in global energy demand and the increased recognition of the impacts of carbon dioxide emissions from fossil fuel plants have aroused a renewed interest on nuclear energy. Many countries are looking afresh at building more nuclear power stations to deal with the twin problems of global warming and the need for more generating capacity. Many in the nuclear community are also anticipating a significant growth of new nuclear generation in the coming decades. If there is a nuclear renaissance, will the expansion of nuclear power be compatible with global non-proliferation and security? or will it add to the environmental burden from the large inventory of spent nuclear fuel already produced in existing nuclear power reactors? We learn from past peaceful nuclear activities that significant concerns associated with nuclear proliferation and spent-fuel management have resulted in a decrease in public acceptance for nuclear power in many countries. The terrorist attack in the United States (US) on September 11, 2001 also raised concern for security and worry that nuclear materials may fall into the wrong hands. As we increase the use of nuclear power, we must simultaneously reduce the proliferation, security and environmental risks in managing spent-fuel below where they are today.

일반병동 전실예정의 중환자실 환자 가족의 부담감 영향 요인 (Factors Influencing on Burden of Family Members of Intensive Care Patients : Planned Transfer to General Ward after Intensive Care)

  • 이혜숙;유미애;이수경;손연정
    • 한국콘텐츠학회논문지
    • /
    • 제14권5호
    • /
    • pp.211-223
    • /
    • 2014
  • 본 연구는 일반 병동으로 전실 예정된 중환자실 환자 가족을 대상으로 중환자실 환자 가족의 부담감에 영향을 미치는 요인을 규명하기 위해 시도된 서술적 횡단조사연구이다. 연구대상은 C시에 소재한 일 대학병원 중환자실에서 일정기간 집중치료를 받고 신체상태가 안정적으로 회복되어 일반병동으로 전실 예정된 환자의 가족 중 연구대상자 선정기준에 적합한 101명이 연구 분석대상에 포함되었다. 자료수집 기간은 2010년 8월부터 11월까지였으며, SPSS 18.0 프로그램을 이용하여 자료 분석을 시행하였다. 연구 결과, 중환자실 환자 가족의 객관적 부담감은 전실 시 환자의 의식수준, 환자 몸에 부착된 기계장치의 수, 기관절개관 여부에서 통계적으로 유의한 차이가 나타났으며, 환자 가족의 주관적 부담감의 경우 환자의 성별, 환자의 교육수준, 환자와의 관계 항목에서 통계적으로 유의한 차이가 나타났다. 중환자실 환자 가족의 전실불안은 객관적 주관적 부담감과 통계적으로 유의하게 순상관관계를 보였고, 본 연구의 주요 결과인 회귀분석에서 환자 가족의 부담감 영향요인으로 객관적 부담감의 경우 전실불안이, 주관적 부담감은 환자 성별과 전실불안이 통계적으로 유의한 독립변인으로 제시되었고, 각각의 설명력은 12.7%와 23.8%로 나타났다. 본 연구결과, 일반 병동으로 전실 예정된 환자 가족의 전실불안이 환자 가족의 객관적, 주관적 부담감을 증가시키는 요인으로 나타나, 향후 본 연구결과를 토대로 중환자실 퇴실 환자와 그 가족을 대상으로 각 대상자의 요구도를 반영한 맞춤형 전실교육을 통해 환자가족의 부담감을 적극적으로 낮출 수 있는 방안이 마련되어야 할 것이다.