• Title/Summary/Keyword: Power balance

Search Result 1,150, Processing Time 0.024 seconds

A Validation Model for the Statistical Power Balance Method Using a Reverberation Chamber

  • Lee, Young Seung;Choi, Sung Woong;Park, Seung Keun
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.3
    • /
    • pp.192-194
    • /
    • 2013
  • This paper proposes a validation model using a reverberation chamber for verification of the effectiveness and accuracy of the statistical power balance (PWB) method. The PWB method treats electromagnetic (EM) field distributions in certain environments as a representative value of an "ensemble" average, so a reverberation chamber is utilized as a testing apparatus to experimentally simulate the sets of measurement field "ensemble" inside a complex environment. Measurements are performed with various test conditions for environmental loss using flat absorbers, and front and side doors of the chamber. Comparison between the PWB analysis and the measurement results shows good agreement, indicating the usefulness of this statistical analysis method for stating the electromagnetic field inside the EM zone as a representative value to general structures.

Thermal Performance Simulation of Cogeneration Power Plants (열병합 발전플랜트의 열성능 해석)

  • Lee, Dong-Won;O, Myeong-Do;Lee, Jae-Heon;Jo, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.451-460
    • /
    • 2001
  • An analysis program for the thermal performance prediction of steam turbine cogeneration systems with multi-extraction, reheat and regeneration has been developed on the basis of the thermodynamic heat balance method. Heat balance analyses were performed for a commercial cogeneration power plant using the program. Its appropriateness was verified by comparing its heat balance results with those of other commercial programs and those provided by the original system designer. Further parametric analyses were carried out and performance improvement measures in designing the plant were suggested.

PERUPS (PERFORMANCE UPGRADE SYSTEM) FOR ON-LINE PERFORMANCE ANALYSIS OF A NUCLEAR POWER PLANT TURBINE CYCLE

  • KIM SEONGKUN;CHOI KWANGHEE
    • Nuclear Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.167-176
    • /
    • 2005
  • We developed the PERUPS system to aid the on-line performance analysis for the turbine cycle of the YongGwang 3 and 4 nuclear power plants. Procedure of measurement validation is included in the performance calculation to obtain heat balance. Precision of on-line performance calculation is increased via practical modifications of standard calculation algorithms based on the PTC (Performance Test Code). The proposed system also provides useful Web-based aids for performance analysis, including performance data management, a graphic viewer for heat balance and turbine expansion lines, and synthesized reports of performance.

Sequence Pulse Modulation for Voltage Balance in a Cascaded H-Bridge Rectifier

  • Peng, Xu;He, Xiaoqiong;Han, Pengcheng;Lin, Xiaolan;Shu, Zeliang;Gao, Shibin
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.664-673
    • /
    • 2017
  • With the development of multilevel converters, cascaded single-phase H-bridge rectifiers (CHBRs) has become widely adopted in high-voltage high-power applications. In this study, sequence pulse modulation (SPM) is proposed for CHBRs. SPM is designed to balance the dc-link voltage and maintain the smooth changes of switch states. In contrast to phase disposition modulation, SPM balances the dc-link voltage even after removing the load of one submodule. The operation principle of SPM is deduced, and the unbalance degree of SPM is analyzed. All the proposed approaches are experimentally verified through a prototype of a four-module (nine-level) CHBR. Conclusions are drawn in accordance with the results of SPM and its imbalance degree analysis.

Implementation of Engine power balance management system through the smart phone (스마트 폰을 통한 엔진파워밸런스 관리 시스템 구현)

  • Kim, Hwa-seon;Jang, Jong-wook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.515-517
    • /
    • 2014
  • 엔진 부조(engine hesitation)의 원인을 추적함에 있어 가장 효과적인 점검방법 중의 하나가 엔진파워 밸런스(engine power balance)를 점검하는 것이다. 본 연구에서는 공회전 상태에서 4개의 실린더 폭발의 압력 편차로 인한 엔진 부조를 점검하기 위해 엔진 파워 밸런스를 점검하는 방법을 사용한다. 엔진의 부조는 네 개의 실린더의 회전 밸런스가 틀어졌기 때문이므로 실린더의 회전 밸런스 정보를 수집 분석하는 방법이 필요하다. 본 연구에서는 실린더의 엔진 회전수를 계산하기 위해 OBD-II와 무선 시스템인 블루투스 모듈을 이용하여 실시간으로 CKP 센서 정보를 수집하는 방법과 밸런스가 틀어진 실린더를 찾는 알고리즘을 제시하여 엔진 파워 밸런스를 조절 관리하는 시스템을 스마트 폰에 구현하고자한다.

  • PDF

A Study on Power-Flow Analysis of The Lepelletier 6-Speed Automatic Transmission (6 속 자동변속기용 레펠레티아 유성 치차의 동력 해석에 관한 연구)

  • 박진홍;심재경;강봉수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.652-655
    • /
    • 2004
  • In gear-train design, power-flow analysis is a very important process. The method for power-flow analysis apply the power balance equation and torque balance equation to each fundamental circuit. Then, the equation are solved simultaneously to determine the power-flow in planetary gear train. In this paper we perform power-flow analysis of a 6-speed automatic transmission. With this results are used to represent block diagram. In addition, the efficiencies of epicyclic inversion of the 6-speed automatic transmission is obtained.

  • PDF

Program Development for Solving the Energy Balance Problem of Liquid Rocket Engine (액체로켓 엔진 Energy Balance 문제 해결을 위한 프로그램 개발)

  • Park, Soon-Young;Nam, Chang-Ho;Cho, Won-Kook
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.135-138
    • /
    • 2006
  • We developed an engine system design program by balancing the pressure-mass-power relation which can be acquired from each component's specification. In gas generator type open-cycle rocket engine system it is possible to distinguish the variables into two categories, which are input variables and requirement variables. We define 11 design variables corresponding to the 11 balance equations as functions of pressure, mass and power of target engine system. We solved these equations by Newton method. As an example we designed gas generator cycle engine system and finally we could conclude that this developed program is well suited to the engine system design.

  • PDF

Influence of Pilates on physical factors related to exercise performance

  • Yu, Jae-Ho;Lee, Gyu-Chang
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.3
    • /
    • pp.57-63
    • /
    • 2011
  • Purpose: The purposes of this study were to investigate the effectiveness of Pilates exercise on Fitness Factors related to motor performance including flexibility, agility, power, balance, and muscle endurance. Methods: Forty subjects were randomly allocated to one of two groups. The Pilates group did Pilates exercises 3 times a week for 8weeks, 60 minutes each time, and submitted to evaluation of protocols to assess sitting and reaching tests, a standing broad jump test, a side step test, a balance test using a Biodex Stability System, and muscle endurance using CSMI. Results: The Pilates group (n=20) participated in Pilates exercises three times in a week for eight weeks. The results show significant post-test differences in the Pilates group in the following areas: flexibility, agility, power, balance and muscle endurance. There was no significant increase in the control group. Post-exercise, there was no significant difference between the Pilates and control group. Conclusion: The Pilates method can offer significant improvement in personal flexibility, agility, power, balance, and muscle endurance. This study suggests that individuals can improve their Fitness Factors related to motor performance using Pilates exercises that do not require equipment or a high degree of skill. Further study is required to quantify the benefits of Pilates exercise.

Novel Method for Circulating Current Suppression in MMCs Based on Multiple Quasi-PR Controller

  • Qiu, Jian;Hang, Lijun;Liu, Dongliang;Geng, Shengbao;Ma, Xiaonan;Li, Zhen
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1659-1669
    • /
    • 2018
  • An improved circulating current suppression control method is proposed in this paper. In the proposed controller, an outer loop of the average capacitor voltage control model is used to balance the sub-module capacitor voltage. Meanwhile, an individual voltage balance controller and an arm voltage balance controller are also used. The DC and harmonic components of the circulating current are separated using a low pass filter. Therefore, a multiple quasi-proportional-resonant (multi-quasi-PR) controller is introduced in the inner loop to eliminate the circulating harmonic current, which mainly contains second-order harmonic but also contains other high-order harmonics. In addition, the parameters of the multi-quasi-PR controller are designed in the discrete domain and an analysis of the stability characteristic is given in this paper. In addition, a simulation model of a three-phase MMC system is built in order to confirm the correctness and superiority of the proposed controller. Finally, experiment results are presented and compared. These results illustrate that the improved control method has good performance in suppressing circulating harmonic current and in balancing the capacitor voltage.

Water Balance Evaluation of Final Closure Cover for Near- surface Radioactive Wastes Disposal Facility

  • Keunmoo Chang;Park, Joo-Wan;Yoon, Jeong-Hyoun;Park, Heui-Joo;Kim, Chang-Lak
    • Nuclear Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.274-282
    • /
    • 2000
  • The simulation of water balance was conducted for suggested four alternative multi-layer cover design of near-surface radioactive waste disposal facility under domestic climate condition. The analysis was also conducted for the most favorable one out of four alternative cover design under conservative scenarios. Until 100 years after closure of disposal vault, the infiltration flux for the most favorable cover design was negligible even under doubling of the ambient precipitation condition. When the degradation of asphalt and geomembrane after 100 years of closure was considered, the infiltration flux significantly increased almost to the design criteria of cover system in I' Aube disposal facility. And it was found that the hydraulic conductivity of bentonite/sand as a bottom barrier should be no greater than 1$\times$10$^{-7}$ cm/sec recommended by U.S. EPA.

  • PDF