A Study of Stability Analysis for Exit Light (유도등의 안정성 해석에 관한 연구)

  • Jung, Jong-Jin;SaKong, Seong-Ho
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.81-85
    • /
    • 2008
  • In this study, Standards of Lighting Appliance and Standard of Model Approval and Inspection Technology for EXIT LIGHT are compared so as to analyze stability of a exit light which is fire product. Test items, which are not included in Standard of Model approval and Inspection Technology for EXIT LIGHT, are deduced from aforementioned comparison and analysis. Also the derived test items are experimented with a exit light. For a power factor correction, a power factor correction circuit is designed and power factor, crest factor, asymmetry ratio, luminance variation are analyzed. In order to show the validity of designed circuit, current waveform and voltage waveform are measured.

Properties and Classification of Patterns of Air Discharges (기중방전의 방전원별 특성분석 및 패턴분류)

  • Park, Yeong-Guk;Lee, Gwang-U;Jang, Dong-Uk;Gang, Seong-Hwa;Jeong, Gwang-Ho;Kim, Wan-Su;Lee, Yong-Hui;Im, Gi-Jo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.19-23
    • /
    • 2000
  • Partial discharges(PD)in air insulated electric power apparatus often lead to deterioration of solid insulation by electron bombardments and electrochemical reaction. The PD caused to reduce the life time of power apparatus and to increase power losses. Thus understanding and classification of PD patterns in air are very important to discern sources of PD. In this paper, PD in air by using statistical methods was investigated. We classified air discharges, corona, surface discharges and cavity discharges by Kohonen network. For classification of PD patterns, we used statistical operators and parameters such as skewness$(S^+,\; S^-),\; kurtosis(K^+, K^-),\; mean phase(AP^+, AP^-)$, cross-correlation factor(CC) and asymmetry derived from the mean pulse-height phase distribution$(H_{avg}(\phi))$, the max pulse-height phase distribution $(H_{qmax}(\phi))$, the pulse count phase distribution $(H_n(\phi))$ and the pulse height vs. Repetition rate $(H_q(n))$.

  • PDF

BER Improvements of 0.96 Tbps WDM Signals through Optimal Parameter Values of Optical Phase Conjugator (광 위상 공액기의 최적 파라미터 값 도출을 통한 0.96 Tbps WDM 신호의 BER 개선)

  • Lee, Youngkyo
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.11 no.1
    • /
    • pp.79-88
    • /
    • 2015
  • In this paper, it is investigated that the limitation due to the asymmetry of optical power and chromatic dispersion with respect to optical phase conjugator (OPC) for compensating optical signal distortion in WDM system is overcomed by using OPC position offset and optimal dispersion coefficients of fiber sections, which depend on OPC position offset. It is confirmed that overall WDM channels are efficiently compensated by applying the optimal parameter values obtained from the proposed method into 24 channels ${\times}40$ Gbps WDM system with non zero - dispersion shifted fiber (NZ-DSF) of 1, 000 km, such as power penalties of inter-channel are reduce to almost 3.5 dB from the infinite value. It is also confirmed that the flexible design of WDM system with OPC is possible by using the optimal parameters, in which OPC is placed at ${\pm}15km$ from 500 km for efficiently compensating overall channels. Thus, the methods proposed in this research will be expected to alternate with the method of making a symmetrical distribution of power and local dispersion in real optical link which generates a serious problem if it was not made but it is the condition in the case of applying the OPC into multi-channels WDM system.

Reducing Vibration of a Centrifugal Turbo Blower for FCEV Using Vibrational Power Flow (진동 동력 흐름 기법을 이용한 FCEV용 원심형 터보 블로워의 진동 저감)

  • Kim, Yoon-Seok;Lee, Sang-Kwon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.2
    • /
    • pp.150-158
    • /
    • 2009
  • A centrifugal turbo blower is one of the part to generate electric power of fuel cell electric vehicle(FCEV). In order to generate the electric power of FCEV, the centrifugal turbo blower operates at very high speed above 30,000rpm in order to increase the pressure of the air, which supplied to a stack of FCEV, using rotation of its impeller blades. Vibration which originated from the blower is generated by unbalance of mechanical components, rotation of bearings and rotating asymmetry that rotate at high speed. The vibration is transmitted to receiving structure through vibration isolators and it can causes serious problems in the noise, vibration and harshness(NVH) performance. Thus, the study about reducing this kind of vibration is an important task. Quantifying the effectiveness of vibration isolation can be effectively accomplished by using vibrational power flow because relative contributions of each isolator to the total vibration transmission can be easily represented. In this paper, vibrational power flow is applied to the centrifugal turbo blower mounted on FCEV in order to analyze the most dominant vibration transmitting path. As a result, the main contributor among four isolators is a mount #3 of the blower. Also, a 30 percent lowering of the mount #3 stiffness shows 34 percent decrement of vibrational power flow by the simulation.

Does a Frontal 2-Electrode Electroencephalogram Provide Sufficient Neuropsychological Information in Various Major Psychiatric Disorders?

  • Sol Han;Hyen-Ho Hwang;Kang-Min Choi;Sungkean Kim;Seung-Hwan Lee
    • Anxiety and mood
    • /
    • v.20 no.1
    • /
    • pp.8-16
    • /
    • 2024
  • Objective : The purpose of this study is to compare the signal obtained from the frontal 2-electrodes EEG with that obtained from the temporal, central, and parietal 2 electrodes. Methods : EEGs were recorded in a total of 67 patients with major depressive disorder (MDD), 104 patients with schizophrenia (SCZ), and 29 patients with Alzheimer's disease (AD). For each disease group, there were healthy controls (HC) that were paired accordingly (HC1=69, HC2=104, HC3=27). The following measurements were compared across electrodes: band power, alpha peak frequency (APF), APF power, alpha asymmetry (AA), and Kolmogorov complexity (KC). Results : Statistically significant differences were found in band power measured from frontal electrodes compared to electrodes placed in other locations. Specifically, the power of theta waves was measured higher in the temporal electorodes, alpha 1 and alpha 2 waves in the parietal, beta 1 and beta 2 in the central, and gamma waves in the temporal electrodes. Both SCZ and AD patients showed increased theta power in all electrodes. In SCZ patients, APF decreased in the central and temporal electrodes, but the APF power analysis showed no difference between the patients and controls. Additionally, AD patients exhibited increased AA in the central EEG, while SCZ patients showed decreased KC in the parietal and temporal electrodes. Conclusion : Depending on the electrode location, sensitive EEG frequencies differed. Compared with signals from other electrodes, frontal EEG in MDD patients revealed generally constant signal values, though the temporo-parieto-central electrodes appeared to be more reliable in SCZ and AD patients.

Comparison of Both Legs EMG Symmetry during Over-Ground Walking and Stair Walking in Stroke Patients

  • Jeong, Mu-Geun;Kim, Joong-Hwi
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.4
    • /
    • pp.228-233
    • /
    • 2015
  • Purpose: Gait is the most basic element when evaluating the quality of life with activities of daily living under ordinary life circumstances. Symmetrical use of the lower extremities requires complicated coordination of all limbs. Thus, this study examined asymmetry of muscle activity quadriceps femoris and tibialis anterior as a baseline for training during over-ground walking and stair walking of stroke patients. Methods: Subjects were 14 stroke patients included as one experimental group. Gait speed used in this study was determined by the subject. Low extremity paretic and non-paretic EMG was compared using the surface EMG system. Results: The low extremity EMG difference was statistically significant during over-ground walking and stair walking (p<0.05). The result of low extremity EMG substituted symmetry ratio formula was compared to EMG symmetry ratio in both legs during over-ground walking and stair walking. The average symmetry ratio of quadriceps femoris during over-ground walking was 0.65, and average symmetry ratio of quadriceps femoris during stair walking was 0.47, with significant difference (p<0.05). Conclusion: EMG data was higher in stair walking than over-ground walking. However, in the comparison of symmetry ratio, asymmetric EMG of quadriceps femoris was significantly increased during stair walking. These findings suggested that application of stair walking for strengthening of both legs can be positive, but the key factor is maintaining asymmetrical posture of both legs. Therefore, physical therapists should make an effort to reduce asymmetry of quadriceps femoris power during stair walking by stroke patients.

Analysis of Key Factors in Operational Control Transition Resolution using Analytic Hierarchy Process (AHP) (계층적 분석방법(AHP)을 적용한 전시작전통제권 전환의 주요 결정요인 분석)

  • Park, Sang-Jung;Koh, Chan
    • Journal of Digital Convergence
    • /
    • v.9 no.6
    • /
    • pp.153-163
    • /
    • 2011
  • This study analyzes the military and political factors that influenced the Participatory Government's resolution in Wartime Operational Control (OPCON) Transition. The research on key factors in OPCON transition firstly implemented literature research and then increased feasibility through additional use of AHP. The analysis results showed that there was a negative effect for Korean Peninsular Defense in the 'ROK-US Alliance Asymmetry' area, a positive effect to increase ROK-led Capability of Theater Operation in the 'ROK and U.S. Alliance Interdependence' area and a positive effect for Invocation of ROK Self-Defense Power in the 'Interests of Participatory Government's Liberal Regime' area respectively. After applying AHP, "ROK exercise of Self-defense" in the 'Interests of Participatory Government's Liberal Regime' area received the highest assessment, while the "Increasement of North Korea's Threat" in the 'ROK-US Alliance Asymmetry' area received the lowest assessment. This study is meaningful in that it analyzed the key military and political factors in the Participatory Government's resolution of Wartime OPCON Transition using AHP.

Development of Fault Diagnostic Algorithm based on Spectrum Analysis of Acceleration Signal for Wind Turbine System (가속도 신호의 주파수 분석에 기반한 풍력발전 고장진단 알고리즘 개발)

  • Ahn, Sung-Ill;Choi, Seong-Jin;Kim, Sung-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.675-680
    • /
    • 2012
  • Wind energy is currently the fastest growing source of renewable energy used for electrical generation around the world. Wind farms are adding a significant amount of electrical generation capacity. The increase in the number of wind farms has led to the need for more effective operation and maintenance. CMS(Condition Monitoring System) can be used to aid plant operator in achieving these goals. Its aim is to provide operators with information regarding th e health of their machine, which in turn, can help them improve operation efficiency. In this work, wind turbine fault diagnostic algorithm which can diagnose the mass unbalance and aerodynamic asymmetry of the blades is proposed. Proposed diagnostic algorithm utilizes both FFT(Fast Feurier Transform) of the signal from accelerometers installed inside of nacelle and simple diagnostic logic. Furthermore, to verify the applicability of the proposed system, 3W small sized wind turbine system is tested and physical experiments are carried out.

Changes of EEG Coherence in Narcolepsy Measured with Computerized EEG Mapping Technique (기면병에서 전산화 뇌파 지도화 기법으로 측정한 뇌파 동시성 시성 변화)

  • Park, Doo-Heum;Kwon, Jun-Soo;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.8 no.2
    • /
    • pp.121-128
    • /
    • 2001
  • Objectives: In narcoleptic patients diagnosed with ICSD (international classification of sleep disorders, 1990) criteria, nocturnal polysomnography, and MSLT (multiple sleep latency test), we tried to find characteristic features of quantitative electroencephalography (QEEG) in a wakeful state. Methods: We compared eight drug-free narcoleptic patients with sex- and age-matched normal controls, using computerized electroencephalographic mapping technique and spectral analysis. Absolute power, relative power, interhemispheric asymmetry, interhemispheric and intrahemispheric coherence, and mean frequency in each frequency band (delta, theta, alpha and beta) were measured and analyzed. Results: Compared with normal controls, narcoleptic patients showed decrease in monopolar interhemispheric coherence of alpha frequency bands in occipital ($O_1/O_2$), parietal ($P_3/P_4$), and temporal ($T_5/T_6$) areas and beta frequency band in the occipital ($O_1/O_2$) area. Monopolar intrahemispheric coherences of alpha frequency bands in left hemispheric areas ($T_3/T_5$, $C_3/P_3$ & $F_3/O_1$) decreased. Decrease of monopolar interhemispheric asymmetry of delta frequency band in the occipital ($O_1/O_2$) area was also noted. The monopolar absolute powers of beta frequency bands decreased in occipital ($O_2,\;O_z$) areas. Conclusion: Decreases in coherences of narcoleptic patients compared with normal controls may indicate fewer posterior neocortical interhemispheric neuronal connections, and fewer left intrahemispheric neuronal connections than normal controls in a wakeful state. Therefore, we suggest that abnormal neurophysiological sites of narcolepsy may involve complex areas such as neocortex and subcortex as well as the brainstem.

  • PDF

An Empirical Study on Differential factors of Accounting Information (회계정보의 차별적 요인에 관한 실증연구)

  • Oh Sung-Geun;Kim Hyun-Ki
    • Management & Information Systems Review
    • /
    • v.12
    • /
    • pp.137-160
    • /
    • 2003
  • The association between accounting earnings and the stock price of an entity is the subject that has been most heavily researched during the past 25 years in accounting literature. Researcher's common finding is that there are positive relationships between accounting earnings and stock prices. However, the explanatory power of accounting earnings which was measured by $R^2$ of regression functions used was rather low. To be connected with these low results, The prior studies propose that there will be additional information, errors in variables. This study investigates empirically determinants of earnings response coefficients(ERCs), which measure the correlation between earnings and stock prices, using earnings level / change, as the dependent variable in the return/earnings regression. Specifically, the thesis tests whether the factors such as earnings persistence, growth, systematic risk, image, information asymmetry and firm size. specially, the determinable variables of ERC are explained in detail. The image / information asymmetry variables are selected to be connected with additional information stand point, The debt / growth variables are selected to be connected with errors in variables. In this study, The sample of firms, listed in Korean Stock Exchange was drawn from the KIS-DATA and was required to meet the following criteria: (1) Annual accounting earnings were available over the 1986-1999 period on the KIS-FAS to allow computation of variables parameter; (2) sufficient return data for estimation of market model parameters were available on the KIS-SMAT month returns: (3) each firm had a fiscal year ending in December throughout the study period. Implementation of these criteria yielded a sample of 1,141 firm-year observation over the 10-year(1990-1999) period. A conventional regression specification would use stock returns(abnormal returns) as a dependent variable and accounting earnings(unexpected earnings) changes interacted with other factors as independent variables. In this study, I examined the relation between other factors and the RRC by using reverse regression. For an empirical test, eight hypotheses(including six lower-hypotheses) were tested. The results of the performed empirical analysis can be summarized as follows; The first, The relationship between persistence of earnings and ERC have significance of each by itself, this result accord with one of the prior studies. The second, The relationship between growth and ERC have not significance. The third, The relationship between image and ERC have significance of each by itself, but a forecast code doesn't present. This fact shows that image cost does not effect on market management share, is used to prevent market occupancy decrease. The fourth, The relationship between information asymmetry variable and ERC have significance of each by. The fifth, The relationship between systematic risk$(\beta)$ and ERC have not significance. The sixth, The relationship between debt ratio and ERC have significance of each by itself, but a forecast code doesn't present. This fact is judged that it is due to the effect of financial leverage effect and a tendency of interest.

  • PDF