• Title/Summary/Keyword: Power arc test

Search Result 121, Processing Time 0.033 seconds

Relief Performance of Fault Current and Design/Manufacturing of Polymer Arresters for Power Distribution (배전선로용 폴리머 피뢰기의 모듈 설계/제조 및 성능)

  • Cho, Han-Goo;Yun, Han-Su;Jang, Tae-Bong;Chie, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.175-179
    • /
    • 2005
  • The main objective of this paper is to module design and pressure relief test a new type of polymer gapless surge arrester for power distribution line. Metal oxide surge arrester for most electric power system applications, power distribution line and electric train are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of gapless elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion.

  • PDF

Performance Test of 400kW Enhanced Huels Type Plasma Generator (400kW 개량형 고온플라즈마 발생장치 성능평가연구)

  • Park, Sang-Hun;Lee, Ki-Seon;Lee, Sueng-Jin;Hwang, Lee-Ho;Rhee, Byong-Ho;Na, Jae-Jeong;Lee, Jung-Min
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.537-540
    • /
    • 2010
  • An Enhanced Huels Type Plasma Torch that generates over $5000^{\circ}C$ plasma arc flow is the core equipment of arc-jet wind tunnel. It is applied to the high-tech areas such as a new materials development and eco-friendly industry. Although the Enhanced Huels Type Plasma Torch produce uniform flow of high purity, its complicated structure and operating condition makes the commercialization of it to be difficult. The 400kW arc-jet generator using the enhanced Huels type plasma torch was tested. The result of this study showed that the torch was operated in the range of 280~320 A and 250~1350 V.

  • PDF

Comparative analysis of weldability using a three-point bending test of a movable iron core welder and a digital welder that outputs a sine wave (가동 철심형 용접기와 정현파를 출력하는 디지털 용접기의 3점식 굽힘시험을 이용한 용접성 비교 분석)

  • Jong-Sig Kim;Kwang-Ho Lee;Yi-Hwan Joo;Jong-Chul Koh;Gyeong-Yeol Yun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.605-611
    • /
    • 2023
  • In this study, in order to reduce energy that affects the natural environment, a moving iron core type welding machine and a digital welding machine (inverter type) with low power consumption are compared in shielded arc welding, and the parts that use less power and have the same weldability conditions are identified. want to check. The movable iron core welder uses alternating current that outputs a sine wave, and the digital welder also generates a sine wave alternating current, so it must have the same conditions, low power consumption, and the same weldability. However, weldability can be verified in various ways, but the analysis is limited to the qualification test in the field of national technical qualification welding.

A Study on Module Design and Performance of Polymer Arrester (폴리머 피뢰기의 모듈 설계 및 성능에 관한 연구)

  • Cho, Han-Goo;Chun, Jong-Uk;Kang, Yeong-Kil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05e
    • /
    • pp.108-111
    • /
    • 2003
  • The main objective of this paper is to module design and pressure relief test a new type of polymer gapless surge arrester for power distribution line. Metal oxide surge arrester for most electric power system applications, power distribution line and electric train are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of gapless elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion.

  • PDF

A Study on Microstructure, Mechanical Properties, Friction and Adhesion of TiN Thin Films Coated on SKD61 and Radical Nitrided SKD61 Substrates by Arc Ion Plating (SKD61과 Radical Nitriding 처리된 SKD61 기판상에 Arc Ion Plating으로 증착된 TiN 박막의 미세구조 및 기계적 특성, 마찰 및 접착력에 관한 연구)

  • Joo, Yun-Kon;Yoon, Jae-Hong;Fang, Wei;Zhang, Shi-Hong;Cho, Tong-Yul;Ha, Sung-Sik
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.6
    • /
    • pp.254-257
    • /
    • 2007
  • TiN coating on tool steel has been widely used for the improvement of durability of tools. In this work, radical nitriding(RN) is carried out on SKD61 at $450^{\circ}C$ for 5 hours in the ammonia gas pressure $2.7{\times}10^3\;Pa$. The TiN coating is carried out by arc ion plating(AIP) with the process parameters: arc power 150 A, bias voltage -50V, coating time 40 minutes and nitrogen gas pressure $4{\times}10^3\;Pa$. Hardness, elastic modulus, friction coefficient and adhesion of TiN coating on substrates of both TiN/SKD61 and TiN/RN SKD61 coatings are investigated comparatively. The primary crystalline faces of TiN surface are(200) and(111) for TiN/SKD61 and TiN/RN SKD61 respectively. In addition to the primary phase, Fe phase exists in TiN/SKD61 coating, but not in TIN/RN SKD61. The hardness of TiN/RN SKD61 is about 700 Hv, 250 Hv(56%) higher than that of TiN/SKD61 at the near interface of TiN and substrates. At the TiN surface, hardness of TiN/RN SKD61 is 2,149 Hv, 71 Hv(3%) higher than that of TiN/SKD61. The elastic modulus of TiN coating is improved to 26.7 GPa(6%) by radical nitriding. The adhesion is improved by the RN coating showing no spalling. buckling and chipping on the scratch test track which are shown on the non-RN TiN/SKD61.

Development of a Rotating Device Using Piezoelectric and Micro Displacement System (압전소자와 미소변위 기구를 이용한 회전장치 개발)

  • 강시홍;엄태봉
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.494-497
    • /
    • 2003
  • A rotating device driven by an Inchworm motor was designed and fabricated to be used as an angie standard system. 1. PZT was adopted as a driving source, while the movement of PZT was guided by the leaf spring employing the elastic transformation of metals. 2. The device could rotate in a 360-degree arc. continuously Performance test of the device showed about 0.02 sec. of the minimum revolution angle and 1/15 rpm of the maimum revolution speed. 3. To improve its performance requires further studies on realizing a shifting device with faster response time, on increasing the output current (capacity) of the power amplifier used to drive PZT, on the dynamic motion of clamping. and on determining the optimum clamping condition

  • PDF

Overhead Catenary Measurement by High-speed Image Analysis (고속 이미지 분석에 의한 전차선로 계측)

  • Park, Young;Lee, Ki-Won;Cho, Hyeon-Young;Kwon, Sam-Young;Park, Chan-Bae;Park, Hyun-June
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.824-828
    • /
    • 2007
  • With increasing interest in the reduction of cost for operation and maintenance of overhead catenary system, various methods of condition monitoring have been developed and used in with high-speed analysis and advanced image processing techniques. This study utilizes a high-speed camera as inspecting system to measure the wear, stagger, hight and arc extinguishing test of overhead catenary system. All measuring image were captured by a high speed CMOS camera with PCI express output, which can acquire up to 1000 frames per second with the resolution 1024 × 1280 pixels. Line type laser source with a power equal to 300 mW and the National Instrument LabVIEW (8.0) based on vision acquisition software have been used in application programming interface for image acquisition, display, and storage. The proposed high-speed camera system is finally applied to measure the overhead catenary system showing promising on-field applications

  • PDF

The Electrical Properties Dependent on the Filler in Silicone Composite Material for Power Distribution (옥외용 실리콘 고무 절연재료의 전기적 특성)

  • Kim, J.H.;Park, Y.G.;Kim, I.S.;Cho, H.G.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1597-1599
    • /
    • 1996
  • In this study, we investigated the electrical characteristics such as tracking resistance, dielectric constant, insulating resistance, and arc resistance, of silicone rubber for outdoor use, and, focused on the tracking resistance. In the Inclined Plane Test, two kind of the contamination solutions were used, and their phenomena were observed. The average leakage current and the tracking breakdown time decreased, and erosion rate increased, using anionic surfactant added contaminant solution. The dielectric constant and dissipation factor were increased with increasing temperature.

  • PDF

Study of Self-excited Resonant DC Circuit Breaker in Future DC Grid (향후 DC 전력 계통에서의 자려 공진 DC 차단기에 관한 연구)

  • Guo, Qinglei;Yoon, Minhan;Jang, Gilsoo
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.396-397
    • /
    • 2015
  • With the increasing utilization of high-voltage, direct current (HVDC) transmissions in modern power systems, the DC grid is becoming a hot topic in academic and practical systems. In the DC grid, one of the urgent problems is the fast clearance of the DC fault in the DC network. One preferred method is to isolate the faulty point from the DC network in a short time. The DC circuit breaker is to interrupt the overcurrent after DC faults occur. In this paper, a self-excited resonant DC circuit breaker is an easy and cheap equipment to interrupt the DC fault current. The Mayr's arc model is utilized to simulate the self-excited DC circuit breaker in a DC test system in PSCAD/EMTDC.

  • PDF

Comparison of the Product Properties between Combustion Analysis and Measurement (보일러 연소해석시와 측정시의 연소가스 중량 및 체적비교)

  • Jang, Suck-Won;Rhim, Sang-Kyu;Jung, Hoon;Lee, In-Cheol
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.368-372
    • /
    • 2003
  • There arc two methods to evaluate the combustion product, that is analysis method and measurement method. Properties of the combustion products, constituents, and quanties, can be used to calculate boiler efficiency and beat losses. Using combustion evaluation methods combustion calculation were performed at certain condition and analyze the results. In this paper by comparing the results between two methods, deviation, correction and possibility of site application were confirmed

  • PDF