• Title/Summary/Keyword: Power arc

Search Result 811, Processing Time 0.026 seconds

Protection Relay Coordination Study for Reducing Arc Flash Hazard (아크플래시 장해 대책 보호계전기 협조 검토)

  • Lee, Kang-Wan;Yang, Jung-Oock
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.545-546
    • /
    • 2015
  • Arc flash hazard study is required for the electric power system of industrial plant nowadays. Arc flash incident energy and level are calculated by arc flash hazard study. The arcing fault clearing time is determined by the response time of protection devices. This paper is protection devices coordination study to reduce potential incident energy for industrial electric power system.

  • PDF

Assessment of effects on Arc-Furnace Load cutailment in Emergency (아크로 긴급 차단 시 계통 전압변동 영향 평가)

  • Park, Hyun-Taek;Kim, Jae-Chul;Im, Sang-Gug;Oh, Dong-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.57-59
    • /
    • 2004
  • Arc-furnace is one of the large loads in the electric power system. When the arc-furnace operates, it may cause a bus voltage fluctuation in the power system, because it consumes a lot of reactive power. In this paper, we simulated this phenomenon by using a PSAF program with on-site measured arc-furnace load for different amount of cutailment load.

  • PDF

A Study of Harmonics by Arc Furnace Operating for Demand Side Management (수요관리를 위한 아크로 운전 상태에 따른 고조파 연구)

  • Park, Kyung-Ho;Kim, Jae-Chul;Park, Hyun-Teak;Im, Sang-Kug;Oh, Dong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.17-19
    • /
    • 2003
  • Electric arc furnace has consumed plenty of power. Hence electric arc furnace can be expected to use for demand side management. When electric arc furnace use for demand side management, electric arc furnace frequently occur a starting and a stop. Electric arc furnace irregularity change consumption of power. Due to character of time-varing and non-linear, electirc arc furnace has a problem with voltage quality(flicker, harmonics). Producted harmonic in electric art furnace is different any harmonic source because of electric arc furnace peculiar operating. Accordingly, analysis for generated harmonic in electric arc furnace operating is demanded. This paper analyze effect of harmonic by arc furnace operating.

  • PDF

DC Arc Characteristics Analysis according to U1699B Test Standardof the Status (태양광발전설비 DC 아크특성 분석)

  • Wan-Su Kim;Kwang-Muk Park
    • Current Photovoltaic Research
    • /
    • v.11 no.4
    • /
    • pp.118-123
    • /
    • 2023
  • The main cause of solar facility fires is arc, and in the last 3 years ('16 to '18), about 80% of domestic solar facility fires have been caused by arcs. The capacity of solar power facilities installed around the world continues to increase, and fires caused by arcs are also expected to increase as the solar power generation facilities that were initially installed become obsolete, In this paper, an arc generation test was conducted based on the UL1699B test standard. As a result of the test, the arc generation satisfied the minimum arc current according to the test conditions, and DC arc characteristics were analyzed through data such as arc voltage and arc current according to variables such as speed of moving electrodes and electrode spacing.

760 V-Class DC Switch Breaking Characteristics Using Tandem Type Magnet Extinguisher (탠덤형 자석 소호기를 사용한 760V급 직류 개폐기의 차단 특성)

  • Kim, Hyosung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.3
    • /
    • pp.175-179
    • /
    • 2022
  • Magnetic arc extinguishing technology is effective as an extinguishing device for low-voltage direct current (DC) circuit breakers with a resistive load of ≤4 kW. The separation distance between the magnet and the electrical contact must be shortened to increase the magnetic arc extinguishing force. However, if the magnet is installed too close to the electrical contact points, the magnet is exposed to high temperatures due to the arc current generated when the load current is cut off and the magnetism is lost. To solve this problem, the effective magnetic flux density at the electrical contact can be maintained high by placing the arc extinguishing magnet in a tandem structure with the electrical contact point between them, and the proper separation distance between the contact points and the magnet can be maintained. In addition, an electric arc extinguishing technology that emits arc energy using a series circuit of diode and resistor is used to suppress the continuous arc voltage generated by the inductive load. For the proposed circuit breaker, the breaking characteristics are analyzed through the breaking test for the DC load of the 760 V level, the load power of 4 kW, and the time constant of 5 ms, and an appropriate arc extinguishing design guideline is proposed.

DWT-Based Parameter and Iteration Algorithm for Preventing Arc False Detection in PV DC Arc Fault Detector (태양광 직렬 아크 검출기의 오검출 방지를 위한 DWT 기반 파라미터 및 반복 알고리즘)

  • Ahn, Jae-Beom;Lee, Jin-Han;Lee, Jin;Ryoo, Hong-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.100-105
    • /
    • 2022
  • This paper applies the arc detection algorithm to prevent the false detection in photo voltaic series arc detection circuit, which is required not only to detect the series arc quickly, but also not falsely detect the arc for the non-arc noise. For this purpose, this study proposes a rapid and preventive false detection method of single peak noise and short noise signals. First, to prevent false detection by single peak noise, Discrete wavelet transform (DWT)-based characteristic parameters are applied to determine the shape and the amplitude of the noise. In addition, arc fault detection within a few milliseconds is performed with the DWT iterative algorithm to quickly prevent false detection for short noise signals, considering the continuity of serial arc noise. Thus, the method operates not only to detect series arc, but also to avoid false arc detection for peak and short noises. The proposed algorithm is applied to real-time serial arc detection circuit based on the TMS320F28335 DSP. The serial arc detection and peak noise filtering performances are verified in the built simulated arc test facility. Furthermore, the filtering performance of short noise generated through DC switch operation is confirmed.

Frequency Domain Analysis of the Linear Load for Series Arc Detection (선형부하의 직렬아크검출을 위한 주파수영역 분석)

  • Kang, Kyoung pil;Bang, Sun Bae;Cho, Younghoon;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.524-525
    • /
    • 2014
  • In this paper, we propose algorithm plan variable for detection of DC arc. Changes of surrounding frequencies of harmonic wave is proposed to detect DC arc. To prove validity of these variables, we analyzed frequency based on the measured data and waveform of load current by performing the experiment which generates DC arc by using DC arc generator regulated in UL1699 was carried out.

  • PDF

A Study of Arc Detection at DC Power System (직류 시스템에서의 아크 검출에 관한 연구)

  • Ban, Gi-Jong;Kim, Jin-Woo;Won, Young-Jin;Lim, Sung-Ha
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.461-462
    • /
    • 2007
  • DC Arc is an electric discharge which is occurred in two oppolsite electrode when system operating with DC current appliance. In this paper, DC arc detection system is designed for the display of DC arc fault current which is occurred in the local electric network with DC Power. This DC arc is one of the main causes of electric fire of dc system. Arc fault in electrical network has the characteristics of low current, high impedance and low frequency. DC Arc current detection device is designed for the display of arc fault current which has the modified arc characteristics.

  • PDF

Arc Detection Performance and Processing Speed Improvement of Discrete Wavelet Transform Algorithm for Photovoltaic Series Arc Fault Detector (태양광 직렬 아크 검출기의 검출 성능 및 DWT 알고리즘 연산 속도 개선)

  • Cho, Chan-Gi;Ahn, Jae-Beom;Lee, Jin-Han;Lee, Ki-Duk;Lee, Jin;Ryoo, Hong-Jae
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.1
    • /
    • pp.32-37
    • /
    • 2021
  • This study proposes a DC series arc fault detector using a frequency analysis method called the discrete wavelet transform (DWT), in which the processing speed of the DWT algorithm is improved effectively. The processing time can be shortened because of the time characteristic of the DWT result. The performance of the developed DC series arc fault detector for a large photovoltaic system is verified with various DC series arc generation conditions. Successful DC series arc detection and improved calculation time were both demonstrated through the measured actual arc experimental result.

Development of a Mixed Chaotic Electric Arc Furnace Model (전력 품질 해석을 위한 개선된 전기아크로 모델 개발)

  • Jang, Gil-Soo;Wang, Weiguo;Lee, Byongjun;Kwon, Sae-Hyuk
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.2
    • /
    • pp.90-95
    • /
    • 2001
  • Electric arc furnaces (EAFs) has a process to cause the degradation of the electric power quality such as voltage flicker. In order to adequately understand and analyze the effects on the power system from these loads, obtaining an accurate representation of the characteristics of the loads is crucial. In this paper, a mixed chaotic EAF model to represent the low frequency and high frequency variations of the arc current respectively has been proposed. The Lorenz system may contribute to the low frequency components of arc current and the logistic equation may contribute to the high frequency components, and the proposed mixed model will be a combination of both Lorenz and logistic model. The concept of chaotic parameters, such as chaotic resistance, inductance of admittance has been also proposed for the characterization of arc furnace operation and the highly nonlinear physical processes. The power quality indices are calculated from the simulated waveforms and compared with the actual power quality indices statistics in order to illustrate the model's capabilities.

  • PDF