• 제목/요약/키워드: Power and phase detecting

Search Result 99, Processing Time 0.025 seconds

The Digital Butterworth Filter of STATCOM for detecting negative sequence components of Unbalanced Load currents (불평형보상용 STATCOM의 역상분 전류 검출을 위한 디지털 버터워쓰 필터)

  • Lim, Su-Saeng;Lee, Eun-Woong;Son, Hong-Kwan;Kim, Seok-Kon;Kim, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11b
    • /
    • pp.333-335
    • /
    • 2000
  • STATCOM(static synchronous compensator : one of the custom power equipment) can be used for balancing unbalanced loads. Compensation current references are given by the analysis of the unbalanced 3-phase currents. And for detecting negative-sequence components, a digital Butterworth Filter is designed. Finally a negative sequence component of an unbalanced load current is acquired using the digital Butterworth Filter.

  • PDF

A Novel Method for Anti-Islanding Using Reactive Power (무효전력 제어를 이용한 새로운 독립운전 방지 기법)

  • Choi, Bong-Joo;Jeong, Jin-Beom;Kim, Hee-Jun;Baek, Soo-Hyun;Lee, Ju;Ahn, Kang-Soon
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.203-206
    • /
    • 2004
  • An islanding occurs when the utility grid is removed but distributed sources continuo to operate and provide power to local loads and grid. This can cause a significant risk to safety and equipment. This report present a novel anti-islanding method to prevent an islanding phenomenon. The proposed method changes the reactive power of the load. Therefore the phase difference between output voltage and current is periodically changed within decided value. When the utility-grid is removed, the frequency of output voltage and current will increase or decrease. And the proposed system will detect the change of frequency and shut down the distributed source. While the conventional methods have some difficulties in detecting particular islanding condition such as a small change in loading, the proposed method can detect most conditions. The performance was verified through experiments.

  • PDF

Application of Wireless Sensor for Diagnostics of Electric Equipments (전력 설비 진단을 위한 무선 센서의 응용)

  • Yun, Ju-Ho;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2112-2113
    • /
    • 2008
  • The concept is based on distributed wireless sensors that are attached to the incoming and outgoing power lines of secondary substations. A sensor measures only phase current characteristics of the wire it is attached to, is not synchronized to other sensors and does not need configuration of triggering levels. The main novelty of the concept is in detecting and locating faults by combining power distribution network characteristics on system level with low power sampling methods for individual sensors. This concept enables the sensor design to be simple, energy efficient and thus applicable in new installations and for retrofit purposes in both overhead and underground electrical distribution systems.

  • PDF

500VA Hybrid filter development for harmonic elimination of a single phase power (단상 전원의 고조파 제거용 500VA급 Hybrid 필터 개발)

  • Park, Jong-Yeon;Lee, Hu-Chan;Lee, Bong-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.249-253
    • /
    • 2006
  • Because of the high cost for the active power filter, passive filters have been widly used to absorb harmonic currents of nonlinear loads and can also improve the power factor. They are not often optimal filters because the passive filters are designed with the fixed load conditions. In this paper we proposed the method which only the necessary harmonic filters are operated by detecting the various harmonic current components. By the experimental results using the proposed system for the 500VA rectifier load, we concluded that the researched hybrid filter is cost effective and the performance is better than the passive filter.

  • PDF

A Coherent Phase Sequence Detection Scheme for SLM-based OFDM Systems without Side Information (위상 신호에 대한 부가 정보가 없는 SLM 기반 OFDM 시스템을 위한 동기식 위상 신호 검출 방식)

  • Ryu, Chang Su;Joo, Jung Suk
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.15-20
    • /
    • 2016
  • In this paper, we consider selective mapping (SLM) based OFDM systems without side information, where SLM is one of the promising peak-to-average power ratio (PAPR) reduction techniques due to its simplicity and no distortion in the transmitted signal. First, we construct a new phase sequence where a part of phase sequence is replaced by an orthogonal sequence. Based on the proposed phase sequence, we propose a new scheme for detecting coherently the index of the phase sequence used in transmitter without side information. Computer simulation shows that the proposed detection scheme performs well in SLM-based OFDM systems, and specifically outperforms the existing ones when channel variation is relatively small between sub-carriers used in phase sequence detection.

Sensorless Brushless DC Motor Drive for Frequently Startup

  • Zhou Genfu;Wu Zhigan;Ying Jianping
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.1
    • /
    • pp.50-56
    • /
    • 2005
  • This paper develops a sensorless BLDCM drive for frequently startup. The position information is based on detecting the zero-crossing point of the BEMF that can be directly obtained from the terminal voltage of the floating phase without voltage-dividing and filtering. As a result, this approach makes it possible to detect the rotor position over a wide speed range, especially at a lower speed. A fast startup procedure is also discussed because the induced BEMF signals are not present when motor is at rest. Experimental results shows that the schemes implemented are feasible and the performance achieved are satisfactory.

Wind Power Grid Integration of an IPMSG using a Diode Rectifier and a Simple MPPT Control for Grid-Side Inverters

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.548-554
    • /
    • 2010
  • In this paper, a 1.5 kW Interior Permanent Magnet Synchronous Generator (IPMSG) with a power conditioner for the grid integration of a variable-speed wind turbine is developed. The power-conditioning system consists of a series-type 12-pulse diode rectifier powered by a phase shifting transformer and then cascaded to a PWM voltage source inverter. The PWM inverter is utilized to supply sinusoidal currents to the utility line by controlling the active and reactive current components in the q-d rotating reference frame. While the q-axis active current of the PWM inverter is regulated to follow an optimized active current reference so as to track the maximum power of the wind turbine. The d-axis reactive current can be adjusted to control the reactive power and voltage. In order to track the maximum power of the wind turbine, the optimal active current reference is determined by using a simple MPPT algorithm which requires only three sensors. Moreover, the phase angle of the utility voltage is detected using a simple electronic circuit consisting of both a zero-crossing voltage detecting circuit and a counter circuit employed with a crystal oscillator. At the generator terminals, a passive filter is designed not only to decrease the harmonic voltages and currents observed at the terminals of the IPMSG but also to improve the generator efficiency. The laboratory results indicate that the losses in the IPMSG can be effectively reduced by setting a passive filter at the generator terminals.

Initial Rotor Position Detection a PM Synchronous Motor and Speed Control of an Elevator Door (영구자석 동기전동기의 회전자 초기위치 검출 및 엘리베이터 도어의 속도제어)

  • Song, Ki-Young;Oh, Hyun-Cheal;Cho, Kwan-Yuhl;Kim, Hag-Wone
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.556-564
    • /
    • 2013
  • This paper proposes an initial rotor position detecting algorithm of a PM synchronous motor using an incremental encoder. The proposed algorithm estimates the phase offset between the rotor magnetic flux and the Z-pulse of the incremental encoder by applying six aligning mode current control. The absolute rotor position for driving a PM synchronous motor is calculated by using the phase offset of the Z pulse and A, B pulse signals of the encoder. The PMSM drives based on the estimated rotor position is applied to the elevator door system. The door length is measured on line at first setup of the elevator. The speed control for open, close, and reopen of the elevator door is also presented and the proposed algorithm for the elevator door system is verified by experiment.

Rotor Position Detection and Drive of a Single Phase Switched Reluctance Motor Using a Search Coil (서치코일을 이용한 단상 스위치드 릴럭턴스 모터의 회전자 위치검출 및 구동)

  • Yang Hyong-Yeol;Lim Young-Cheol;Kim Kwang-Heon;Cha Deuk-Keun;Shin Duck-Shick
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.488-493
    • /
    • 2005
  • This paper presents a method of detecting rotor position for single phase Switched Reluctance Motors(SRMs) using a search coil. In the single phase SRM, mainly Hall effect sensors or photo interrupters have been used to detect the rotor position. But these sensors have many disadvantages. In this paper, low cost and robust characteristics of rotor position detection method are focused in order to compensate for disadvantage of existing sensors. Search coils wound around the stator pole are used for detection of the rotor position in single phase SRM. Rotor position detection is achieved through electromotive force patterns induced by time-varying flux linkage in the search coil. The simulation and experimental results are presented to verify the performance of the proposed method in this paper.

Fast Diagnosis Method for Submodule Failures in MMCs Based on Improved Incremental Predictive Model of Arm Current

  • Xu, Kunshan;Xie, Shaojun
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1608-1617
    • /
    • 2018
  • The rapid and correct isolation of faulty submodules (SMs) is of great importance for improving the reliability of modular multilevel converters (MMCs). Therefore, a fast diagnosis method containing fault detection and fault location determination was presented in this paper. An improved incremental predictive model of arm current was proposed to detect failures, and the multi-step prediction method was used to eliminate the negative impact of disturbances. Moreover, a control method was proposed to strengthen the fault characteristics to rapidly locate faulty arms and faulty SMs by detecting the variation rate of the SM capacitor voltage. The proposed method can rapidly and easily locate faulty SMs under different load conditions without the need for additional sensors. The experimental results have validated the effectiveness of the proposed method by using a single-phase MMC with four SMs per arm.