• 제목/요약/키워드: Power Transmission Systems

검색결과 1,408건 처리시간 0.029초

Energy-Efficiency of Distributed Antenna Systems Relying on Resource Allocation

  • Huang, Xiaoge;Zhang, Dongyu;Dai, Weipeng;Tang, She
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제13권3호
    • /
    • pp.1325-1344
    • /
    • 2019
  • Recently, to satisfy mobile users' increasing data transmission requirement, energy efficiency (EE) resource allocation in distributed antenna systems (DASs) has become a hot topic. In this paper, we aim to maximize EE in DASs subject to constraints of the minimum data rate requirement and the maximum transmission power of distributed antenna units (DAUs) with different density distributions. Virtual cell is defined as DAUs selected by the same user equipment (UE) and the size of virtual cells is dependent on the number of subcarriers and the transmission power. Specifically, the selection rule of DAUs is depended on different scenarios. We develop two scenarios based on the density of DAUs, namely, the sparse scenario and the dense scenario. In the sparse scenario, each DAU can only be selected by one UE to avoid co-channel interference. In order to make the original non-convex optimization problem tractable, we transform it into an equivalent fractional programming and solve by the following two sub-problems: optimal subcarrier allocation to find suitable DAUs; optimal power allocation for each subcarrier. Moreover, in the dense scenario, we consider UEs could access the same channel and generate co-channel interference. The optimization problem could be transformed into a convex form based on interference upper bound and fractional programming. In addition, an energy-efficient DAU selection scheme based on the large scale fading is developed to maximize EE. Finally, simulation results demonstrate the effectiveness of the proposed algorithm for both sparse and dense scenarios.

저수지 내 수상태양광의 전압 강하에 의한 직류 송전 손실 (Transmission Loss from Voltage Drop in a DC Cable for a Floating Photovoltaic System in a Reservoir)

  • 방병관;우성철;이원빈;최진호;신승욱;이철성;박미란;원창섭;안형근
    • 신재생에너지
    • /
    • 제16권1호
    • /
    • pp.47-57
    • /
    • 2020
  • In Floating PV (Photovoltaic) systems, PV modules are installed on water by utilizing the surface of idle water such as a reservoir and multipurpose dam. A floating PV system, therefore, has the advantage of efficiency in national land use and improved energy yield owing to cooling effect compared to on-land PV systems. Owing to the limitation of installation environment for a floating PV system, the system, however, has the disadvantage of an increase in transmission distance of DC (Direct current) cables. A longer transmission distance of a DC cable results in greater power loss due to a voltage drop. This leads to a decline in economic feasibility for the floating PV system. In this paper, the economic analysis for 10 floating PV systems installed in a reservoir has been conducted in terms of a change in annual power sales according to the variation of transmission losses depending on the factors affecting the voltage drop, such as transmission distance, cross-section area of underwater cable, the presence of joint box, and PV capacity.

Real-Time Peak Shaving Algorithm Using Fuzzy Wind Power Generation Curves for Large-Scale Battery Energy Storage Systems

  • Son, Subin;Song, Hwachang
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제14권4호
    • /
    • pp.305-312
    • /
    • 2014
  • This paper discusses real-time peak shaving algorithms for a large-scale battery energy storage system (BESS). Although several transmission and distribution functions could be implemented for diverse purposes in BESS applications, this paper focuses on a real-time peak shaving algorithm for an energy time shift, considering wind power generation. In a high wind penetration environment, the effective load levels obtained by subtracting the wind generation from the load time series at each long-term cycle time unit are needed for efficient peak shaving. However, errors can exist in the forecast load and wind generation levels, and the real-time peak shaving operation might require a method for wind generation that includes comparatively large forecasting errors. To effectively deal with the errors of wind generation forecasting, this paper proposes a real-time peak shaving algorithm for threshold value-based peak shaving that considers fuzzy wind power generation.

Optimal Capacity and Allocation of Distributed Generation by Minimum Operation Cost in Distribution Systems

  • Shim Hun;Park Jung-Hoon;Bae In-Su;Kim Jin-O
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권1호
    • /
    • pp.9-15
    • /
    • 2005
  • In the operation of distribution systems, DGs (Distributed Generations) are installed as an alternative to extension and the establishment of substations, transmission and distribution lines according to the increasing power demand. In the operation planning of DGs, determining optimal capacity and allocation achieves economical profitability and improves the reliability of power distribution systems. This paper proposes a determining method for the optimal number, size and allocation of DGs in order to minimize the operation costs of distribution systems. Capacity and allocation of DGs for economical operation planning duration are determined to minimize total cost composed with power buying cost, operation cost of DGs, loss cost and outage cost using the GA (Genetic Algorithm).

UPFC Performance Control in Distribution Networks for DG Sources in the Islanding

  • Fandawi, Ahmed;Nazarpour, Daryoosh
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권5호
    • /
    • pp.303-309
    • /
    • 2017
  • The flexible AC transmission system (FACTS) provides a new advanced technology solution to improve the flexibility, controllability, and stability of a power system. The unified power flow controller (UPFC) is outstanding for regulating power flow in the FACTS; it can control the real power, reactive power, and node voltage of distribution networks. This paper investigates the performance of the UPFC for power flow control with a series of step changes in rapid succession in a power system steady state and the response of the UPFC to distribution network faults and islanding mode. Simulation was carried out using the MATLAB's simulink sim power systems toolbox. The results, which were carried out on a 5-bus test system and a 4-bus multi-machine electric power system, show clearly the effectiveness and viability of UPFC in rapid response and independent control of the real and reactive power flows and oscillation damping [6].

직교주파수분할다중화기반 전력선통신에서 대역 효율적인 전송기법 (A spectral efficient transmission method for ofdm-based power line communications)

  • 김병욱
    • 한국산업정보학회논문지
    • /
    • 제19권4호
    • /
    • pp.25-32
    • /
    • 2014
  • 전력선통신은 스마트그리드 기반의 서비스가 제공될 수 있는 네트워크를 위한 미래지향적 기술이다. 전력선통신 채널의 주파수 선택적 페이딩이 있는 환경에서, 직교주파수분할다중화 기술은 신뢰성 있는 통신을 제공한다. 본 논문에서는 직교주파수분할다중화 기반의 전력선통신 시스템에서 은닉학습신호를 이용한 주파수사용효율이 높은 기법을 제안한다. 은닉학습신호를 사용하면 채널 추정용 주파수를 따로 소모하지 않고도 채널 추정이 가능하고, 이는 데이터와의 간섭을 줄일 수 있는 학습신호에 할당된 파워를 이용해서 해결할 수 있다. 컴퓨터 시뮬레이션을 통해 제안한 기법이 기존의 기법들에 비해 저전압 및 중전압 송전 라인에서 높은 성취 가능한 데이터 율을 보여준다.

웜기어의 강도평가 및 설계시스템 개발에 관한 연구 (Development of Durability Estimation and Design Systems of Worm Gears)

  • 정태형;백재협
    • 한국자동차공학회논문집
    • /
    • 제5권1호
    • /
    • pp.216-216
    • /
    • 1997
  • We developed the durability estimation and design systems to minimize the volume, considering the durability, efficiency, and design requirements of worm gears. That is, we consider each kind of factors affecting on durability on the basis of AGMA Standard for the cylindrical and double-enveloping worm gears. We also estimate input power on the basis of wear and durability, bending strength and deflection of worm shaft, and we developed the durability estimation and design systems of power transmission worm gears introducing the optimal design method on the personal computer to be easily used in field. Also, we developed a method which converts the design variables obtained from the optimal design method to integer values(number of worm threads, number of worm threads, number of worm wheel teeth, etc.,) to be used in real design and production. The developed durability estimation and design method can be easily applied to the design of worm gears used as power transmission devices in machineries and is expected to be used for weight minimization of worm gear unit.

EMTP를 이용한 광 복합 지중송전케이블 광 유니트 금속관의 시스템 영향분석 (Analysis on System Effects of SUS Tube in Optical Fiber Composite Power Cable Systems Using EMTP)

  • 정채균;장태인;강지원
    • 전기학회논문지
    • /
    • 제63권9호
    • /
    • pp.1180-1185
    • /
    • 2014
  • This paper describes the effects on SUS tube of power optical fiber composite cable on underground transmission lines. The effects on grounding, air gap between SUS tube and metal sheath, contact resistance between outer semi-conducting layer and metal sheath and grounding of SUS tube application or not are variously analysed using EMTP in normal operating condition as well as single line to ground fault. From these results, in this paper, the scheme for protecting the electrically abnormal phenomena will be established on power-optical fiber composite cable of underground transmission lines. This paper can contribute to specification of grounding reference of SUS tube of optical fiber composite power cable system.

송전계통 보호계전기 정정값 검증을 위한 고장 시뮬레이터 개발 (A Fault Simulator for Power Transmission System Protective Relay Setting Evalutation)

  • 김기화;최면송;이승재
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.712-718
    • /
    • 1999
  • When a fault occurs in power transmission systems, protective relays play a roles of protecting the power system according to there setting values. Therefor, it is important that protective relays have high selectivity and sensitivity by correct setting the involves a large volume of data and is a complicated and very tedious, therefore vulnerable to the human errors. Also, it is very difficult to verify that the relays have correct operating parameters before the fault occurs. This paper porposed a method to testify the reliability of realys by showing the operation response to faults in the simulation of the real power system operation environment.

  • PDF

SIR 기반의 셀룰러 무선망에서 전송 전력 제어 알고리듬의 성능 비교 (Performance Evaluation of Transmission Power Control Algorithms in SIR-based Cellular Wireless Networks)

  • 정보환;김문갑
    • 대한전자공학회논문지TC
    • /
    • 제46권5호
    • /
    • pp.64-69
    • /
    • 2009
  • 이 논문에서는 SIR 기반의 셀룰러 무선망에서 전송 전력 제어 알고리듬들의 성능을 수치실험을 통해 평가하였다. 이를 위해 SIR 기반의 연속 및 이산 시간 전송 전력 제어 알고리듬을 하나로 통합된 동적 상태 방정식으로 표현하였다. 수치실험은 연속성을 갖는 외란 환경 하에서 수행되었다. 수치실험 결과 본 논문에서 제안한 전송 전력 제어 알고리듬이 보다 우수한 외란 제거 성능을 명백히 보여 준다.