• 제목/요약/키워드: Power Transmission System

검색결과 3,176건 처리시간 0.029초

지게차용 동력전달장치의 조립라인 전용시험기 개발 (Development of the Assembly Line Tester of Power Transmission for Lift Truck)

  • 장경열;유우식
    • 산업공학
    • /
    • 제23권1호
    • /
    • pp.58-67
    • /
    • 2010
  • The purpose of this paper is to present the development processes of the assembly line tester of power transmission for lift truck. Because power transmission is most important part of lift truck, all assembled powertrain parts must be inspected for operational defects, pressures and RPM. Developed assembly line tester is designed to take about 25 minutes for inspecting each assembled power transmission and located it at the end of assembled line. The assembly line no-load tester consists of three parts: (1) the driving hardware part; for installing and operating the transmission. (2) control PCB part; send data from sensors to a computer and control driving part, (3) operation software of no-load tester; for an automatic inspection or manual inspection, for database management and printing transcripts.

1.7MHz, 25W급 자기공명 무선전력 전송 시스템 구현 (Implementation of 1.7MHz, 25W Wireless Power Transmission(WPT) System using Coupled Magnetic Resonance)

  • 김성민;조인귀;문정익
    • 전기전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.317-323
    • /
    • 2013
  • 본 논문에서는 자기공명 방식을 이용한 25W급 무선전력 전송 시스템을 설계 및 구현하는 것을 제안하고 있다. 본 논문에서 제안하는 자기공명 방식 무선전력 전송 시스템은 100W급 Class-F 송신기, 1.7MHz대역의 송수신 공진기, 40W급 Full-bridge 다이오드 수신기로 구성되어 있다. 특히 제안된 시스템은 수신기에 전달되는 전력이 부하를 구동할 수 있는 적정레벨로 유지될 수 있도록 송신기와 수신기 사이의 통신을 이용한 송신전력제어 기능을 구현하여 송신기가 최적의 전력을 송신하여 불필요한 전력 낭비를 줄일 수 있도록 구현되었다. 본 논문에서 제안된 시스템 및 송신전력 제어기능을 기반으로 다양한 기기에 동일한 기능의 적용이 가능하며 상용화에 보다 근접할 수 있을 것이다.

Economic analysis of a 22.9 kV HTS power cable and conventional AC power cable for an offshore wind farm connections

  • Jung, Ga-Eun;Dinh, Minh-Chau;Sung, Hae-Jin;Park, Minwon;Yu, In-Keun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제20권4호
    • /
    • pp.60-64
    • /
    • 2018
  • As the offshore wind farms increase, interest in the efficient power system configuration of submarine cables is increasing. Currently, transmission system of the offshore wind farm uses almost AC system. High temperature superconducting (HTS) power cable of the high capacity has long been considered as an enabling technology for power transmission. The HTS cable is a feasible way to increase the transmission capacity of electric power and to provide a substantial reduction in transmission losses and a resultant effect of low CO2 emission. The HTS cable reduces its size and laying sectional area in comparison with a conventional XLPE or OF cable. This is an advantage to reduce its construction cost. In this paper, we discuss the economic feasibility of the 22.9 kV HTS power cable and the conventional AC power cables for an offshore wind farm connections. The 22.9 kV HTS power cable cost for the offshore wind farm connections was calculated based on the capital expenditure and operating expense. The economic feasibility of the HTS power cable and the AC power cables were compared for the offshore wind farm connections. In the case of the offshore wind farm with a capacity of 100 MW and a distance of 3 km to the coast, cost of the 22.9 kV HTS power cable for the offshore wind farm connections was higher than 22.9 kV AC power cable and lower than 70 kV AC power transmission cable.

신재생에너지 예측을 위한 송전선로의 계량 데이터 계산 방법 (Calculation Method of Dedicated Transmission Line's Meteological Data to Forecast Renewable Energy)

  • 백자현;김현진;최순호;박상호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.55-59
    • /
    • 2022
  • This paper introduce Renewable Energy forecasting technology, which is a part of renewable management system. Then, calculation method of dedicated transmission line's meteorological data to forecast renewable energy is suggested. As the case of dedicated transmission line, there is only power output data combined the number of renewable plants' output that acquired from circuit breakers. So it is need to calculate meteorological data for dedicated transmission line that matched combined power output data. this paper suggests two calculation method. First method is select the plant has the largest capacity, and use it's meteorological data as line meteorological data. Second method is average with weight that given according to plants' capacity. In case study, suggested methods are applied to real data. Then use calculated data to Renewable forecasting and analyze the forecasting results.

초고압 송전선로에 의한 TV Ghost 장해 발생 특성 (Characteristics of TV Ghost Interference from Extra High Voltage Transmission Line)

  • 주문노;양광호;이동일;신구용
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권8호
    • /
    • pp.412-417
    • /
    • 2000
  • TV ghost interference can be described as passive interference by the conducting part of transmission lines. In order to survey this interference from large-sized overhead EHV (extra high voltage) transmission line, TV reception quality was measured in the vicinity of that before and after construction. Instrumentation system was composed of ghost analyzer, TV received field intensity meter, VHF/UHF antennas, TV monitor and so on. The system is installed inside the vehicle. TV field intensity and PDUR (Perceived Desired wave to Undersired wave Ratio) are measured to evaluate TV ghost by using the system and vehicle. As the results, the useful data, which can be used to evaluate the effect of TV ghost interference from transmission lines could be obtained. In this paper, it is shown that the range of TV ghost interference from transmission lines can vary according to the frequency of TV electromagnetic wave, an incidence angle to the line and the other conditiions. At present, we are making efforts to establish a PDUR guideline for transmission lines.

  • PDF

우리나라계통의 북상조류 증대를 위한 FACTS 적용방안 연구 (Feasibility Study of FACTS Application for Available Transfer Capability Enhancement in Korean Power System)

  • 장병훈;문승필;윤종수;김수열;백두현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.63-65
    • /
    • 2005
  • Korea Electric Power Corporation (KEPCO) is in charge of the operation and the maintenance for transmission lines and substations in Korean power system which is under the deregulation power market. KEPCO has a main constrain of transmission line toward SEOUL area which is a capital of KOREA because SEOIJL is a huge load of Korean power system. The Korea Electric Power Research Institute (KEPRI)), a division of KEPCO was tasked to study the ATC enhancement of transmission line toward SEOUL using a new line or/and FACTS. This paper summarizes the results of those studies, enhancing the ATC and evaluating the economics.

  • PDF

Rayleigh 페이딩 채널에서 기회전송 유무에 따른 협동 다중 릴레이 시스템의 성능비교 (Performance Comparisons of Cooperative Multi-relay System with/without Opportunistic Transmission in Rayleigh Fading Channel)

  • 김남수
    • 한국인터넷방송통신학회논문지
    • /
    • 제8권4호
    • /
    • pp.25-33
    • /
    • 2008
  • 레일레이 페이딩 채널에서 전력제한을 받는 기회전송 유무에 따른 협동 다중 릴레이 시스템의 성능을 연구하였다. 전제 네트워크의 전력이 제한되었을 때 3가지의 전력 할당방법을 검토하였고, 그 결과 기회전송 전력 할당방식이 다른 전력할당방식에 비해서 가장 좋은 성능을 나타내었다. 전체 네트워크의 전력이 증가할 경우 기회전송 릴레이가 증가하였고, 기회 협동 다이버시티의 차수를 증가시키게 되며, 결국 종단간 성능이 개선됨을 알 수 있었다.

  • PDF

Transmission Power Minimization with Network Coding for Mobile Terminals in Cellular Relay Networks

  • Du, Guanyao;Xiong, Ke;Li, Dandan;Qiu, Zhengding
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제6권9호
    • /
    • pp.2098-2117
    • /
    • 2012
  • This paper jointly investigates the bandwidth allocation, transmission strategy and relay positions for two-way transmission aware cellular networks with network coding (NC). Our goal is to minimize the transmission power of mobile terminals (MTs). Consider a cellular system, where multiple MTs exchange information with their common base station, firstly, we propose an efficient bandwidth allocation method and then give a transmission strategy for each MT to determine whether to use relay stations (RSs) for its two-way transmission with the BS or not. To further improve the system performance, the optimal positions of RSs are also jointly discussed. A GA-based algorithm is presented to obtain the optimum positions for RSs. Besides, the impacts of frequency reuse on MT's transmission power and system spectral efficiency (SE) under different number of relays are also discussed in our work. Numerical results show that the proposed NC aware scheme can extend MTs' battery life at least 6% more than traditional method.

미얀마 송전선로 설계 기술계산시스템 개발 (Development of the Technical Calculation System for Transmission Line in Myanmar)

  • 백승도;민병욱;김종화;신태우;김세현;박재웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.632-634
    • /
    • 2005
  • Korea takes part in overseas business by use of accumulated advanced technology through construction of the worlds first 765kV double circuit transmission system designed with pure local technology. 'Development Study on the Power System Network Analysis in Myanmar' was received in the year 2001 and was completed in the year 2002. The following project,'Feasibility Study and Basic Designs for the 500kV Transmission System in Myanmar' has been in progress since January, 2004. With regards to this project the master plan for the Myanmar long term power system was submitted in January 2005, and now the basic designs for the 500kV transmission system construction are in progress. Technical data for the design of the transmission line is calculated using a very complex numerical formula that is almost impossible to be completed by hand. So the transmission technical calculation system was developed to calculate and support Myanmar technical data for the design of transmission line with respect to factors such as wind prossure load, tower design data conductor design data and insulator design data on the basis of weather conditions for the Myamar transmission line design area of the Myanmar 500kV trans- mission line construction basic design.

  • PDF

관로부의 동특성을 고려한 공기압 압력용기의 압력제어 (A Study on the Pressure Control of a Pneumatic Pressure Vessel Considering Dynamic Characteristics of Pneumatic Transmission Line)

  • 장지성
    • 동력기계공학회지
    • /
    • 제5권4호
    • /
    • pp.90-96
    • /
    • 2001
  • In this study, a robust controller to control pressure in a pneumatic pressure vessel considering dynamic characteristics of pneumatic transmission line is proposed. Dynamic characteristics of transmission line using compressible fluid is changed by the flowing states of the fluid. So, if the fixed gain controller is designed based on a fixed model, the performance of the control system could be destabilized or degraded. The controller designed in this study is composed of two parts. The one is to reject modelling error based on the disturbance observer, the other is to obtain the control performance. The control results with the designed controller show that the robustness of the control system is achieved regardless of the change of the model of the transmission line. Therefore, the designed controller can be utilized for the performance improvement of the pressure control system using compressible fluid such as air and gas

  • PDF