1선 지락 사고 시 3 권선 변압기에 적용된 초전도 한류기의 동작 특성 분석 (Analysis of Transient Characteristics of a SFCL Applied Into Third-winding Transformer in a Single Line-to-ground Fault)

  • 최혜원;최효상;정병익
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.1033-1037
    • /
    • 2013
  • Coercion transformer is commonly used in the electrical grid which in three phase of distribution system. The accident of the electrical grid is divided into a single, a double, a third line-to-ground faults and a double, a third line-to-line faults. A single line-to-ground fault accounts for nearly 75[%] among them. In this research, when a Superconducting Fault Current Limiters (SFCL) was applied to the three phase power system, operation in a single line-to-ground fault and limiting characteristics of fault current according to turns ratio of third winding were analyzed. When a single line-to-ground fault happened, secondary winding's circuit was open. Then third winding's circuit with a SFCL was closed. So fault current was limited by diverted circuit. At this time, we could find out that size of the limited fault current could be changed according to third winding rate. We confirmed that limiting operation of the fault current was carried out within one-period. These results will be utilized in adjusting the size of the SFCL.

중성선을 갖는 변압기형 초전도 한류기의 용량증대 개선 연구 (Analysis on the Improvement of Power Capacity Increase in the Transformer-Type SFCL with Neutral Lines)

  • 조용선;최효상;김덕구;고성필
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1438-1443
    • /
    • 2011
  • The increase of power capacity in the superconducting fault current limiter (SFCL) is essential for application into the power grid. To achieve this, when superconducting units were connected in series and parallel, the unbalanced quenching characteristics between superconducting units generated by different critical current behavior should be improved. In the transformer-type SFCL, the superconducting units connected in series could be simultaneously quenched by the connection of neutral lines between secondary coils and superconducting units. From this the consumed power in superconducting units was equally distributed. In addition, the more the turn ratio of the transformer was reduced, the more consumed power in the superconducting units was reduced by the decrease of the induction voltage generated in the superconducting units. From those results, the transformer-type SFCL using neutral lines could increase the power capacity of the SFCL by the equal power division into the superconducting units.

Protective Relaying Algorithm for 3-Phase Power Transformer Protection based on Fuzzy Decision Making

  • Kim, Sang-Tae;Lee, Seung-Jae;Kang, Sang-Hee;Park, Myeon-Song;Yoon, Sang-Hyun;Lee, Tae-Sung
    • KIEE International Transactions on Power Engineering
    • /
    • 제12A권1호
    • /
    • pp.26-30
    • /
    • 2002
  • The four fuzzy criteria to distinguish the internal fault from the inrush fur the power transformer protection have been identified. They are based on the wave shape, terminal voltage, fundamental and second harmonic component of differential current. systematic way to determine the associated fuzzy membership function is also proposed.

모의배전계통에 초전도한류기의 도입위치에 따른 전류제한 특성 (Current Limiting Characteristics due to Application Location of a Superconducting Fault Current Limiter in a Simulated Power Distribution System)

  • 유일경;김진석;김명후;김재철;임성훈
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.90-95
    • /
    • 2009
  • 배전계통에서 전력수요의 증가와 분산전원의 증가로 대용량 변압기의 적용이 불가피하게 되었다. 하지만, 대용량 변압기로 교체할 경우 배전계통에 고장발생시 고장전류의 크기가 증가되어 기존에 설치된 차단기 및 보호기기의 차단용량 초과로 인해 교체에 따른 경제적 비용 상승이 우려된다. 따라서, 대용량 변압기의 교체시 고장전류 증가 문제를 해결하기 위한 방안 중 하나로 초전도한류기를 설치하는 방안을 검토하고 있다. 하지만, 초전도한류기는 도입위치에 따라 ��치 발생 시 초전도한류기의 저항 크기가 다르게 되며, 이로 인해 고장전류 제한효과가 다르게 되며 기존의 보호 장치들의 동작에 영향을 주게 된다. 본 논문에서는 모의 배전계통에 초전도한류기를 적용하였을 경우 도입위치에 따라 전류제한효과를 포함하여, 모선 전압강하, 고장제거에 따른 초전도한류기의 회복특성을 실험을 통해 비교 분석하였다.

저항형 초전도한류기의 미래 배전계통 적용방안 (Application Scheme of Resistive HTS-FCL on Future New Distribution System)

  • 이승열;김종율;김호용;윤재영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권5호
    • /
    • pp.212-216
    • /
    • 2005
  • This paper describes the application scheme of resistive HTS-FCL(High Temperature Superconducting-Fault Current Limiter) on future new distribution system. Future new distribution system means the power system to which applies the 22.9kV HTS cable with low-voltage and mass-capacity characteristics replacing the 154kv conventional cable in addition to HTS transformer and HTS-FCL. The fault current of future new distribution system will increase greatly because of the inherent characteristics of HTS transformer/cable and applications of distributed generations and spot networks and so on. This means that the HTS-FCL is necessary to reduce the fault current below the breaking capacity. This paper studies the appropriate location, parameters and the influences of HTS-FCL on future new distribution system. Finally, this paper suggests the reasonable basic parameters of resistive HTS-FCL for future KEPCO new distribution system.

초전도전류제한기의 초전도 전력시스템에서의 운전방안 (The Operating Method of Superconducting Fault Current Limiter for Total Superconducting Power System)

  • 홍원표
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.764-767
    • /
    • 1996
  • Design & operation of power system for meeting increase of electric power demands is becoming more difficult and complex. One of reasons is increase of fault current. As one of the most effective methods for suppressing the fault currents, installation of SFCL are expected. An image of future hybrid & total SC power system which have introduced SC generator cable transformer, fault current limiter, SMES & shunt reactor, etc. are presented. In the SC power system, it is pointed that a SFCL should play an, important part of quenching current level coordination to prevent the other SC devices from quench.

  • PDF

Double quench and fault current limiting characteristics due to winding ratio of transformer type SFCL with third winding

  • Han, Tae-Hee;Ko, Seok-Cheol;Lim, Sung-Hun
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제21권3호
    • /
    • pp.38-42
    • /
    • 2019
  • To protect the power systems from fault current, the rated protective equipment should be installed. However growth of power system scale and concentration of loads caused the large fault current in power transmission system and distribution system. And capacities of installed protective equipment have been exceeded the due to increase of fault current. This increase is not temporary phenomenon but will be steadily as long as the industry develops. The power system need a counter measurement for safety, so superconducting fault current limiter (SFCL) has been received attention as an effective solutions to reduce the fault current. For the above reasons various type SFCL is studied recently. In this paper, the operational characteristics and power burden of trigger type SFCL is studied. The trigger type SFCL has been used for real system research in many countries. And another trigger type SFCL (double quench trigger type SFCL) is also studied. For this paper, short circuit test is performed.

보상 알고리즘을 적용한 변압기 보호용 전류차동 계전방식 (Current Differential Relaying Algorithm for Power Transformer Protection Operating in Conjunction with a CT Compensating Algorithm)

  • 강용철;박종민;이미선;장성일;김용균;소순홍
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1873-1878
    • /
    • 2007
  • Current differential relays may maloperate during magnetic inrush and over-excitation because a significant differential current is produced. To prevent maloperation, the relays adopt some harmonic components included in the differential current. The harmonic restraints may increase the security of a relay but cause the operating time delay of a relay when an internal fault occurs. Moreover, the operating time delay is more increased if a current transformer (CT) is saturated. This paper describes a current differential relaying algorithm for power transformer protection with a compensating algorithm for the secondary current of a CT. The comparative study was conducted with and without the compensating algorithm. The performance of the proposed algorithm was investigated when the measurement CT (C400) and the protection CT (C400) are used. The proposed algorithm can compensate the distorted current of a CT and thus reduce the operating time delay of the relay significantly for an internal fault with CT saturation.

대용량 터빈발전기에서 접지과전압 계전기의 동작 특성 (Dynamic Property of Ground Overvoltage Relay in Large Turbine Generator)

  • 김희동;이영준;김병한;안준영;채규진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1044-1047
    • /
    • 1999
  • This paper deals with the dynamic property of ground overvoltage relay in large turbine generator. Relay operation is based on detecting the fundamental voltages originating from the generator. Calculations of fault voltage and current are reviewed for the neutral ground resistance. The frequency, ampitude and waveform of individual harmonics were measured using power quality analyzer and memory hi-corder at the secondary side of ground potential transformer. The ac and dc high-potential tests were applied to evaluate the condition of generator, main and auxiliary transformer, isolated phase bus, potential transformer, surge capacitor and arrester.

  • PDF

분산전원 연계선로에서 지락고장시 중성선의 과전류 해석 및 보호계전기의 새로운 알고리즘 (An Overcurrent Analysis in Neutral Line and Algorithm to Prevent Malfunction of Relay in Distributed Generations)

  • 신동열;김동명;차한주
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.1916-1922
    • /
    • 2009
  • Introducing distributed generators(DGs) to utility distribution system can cause malfunction of relay on the grid when ground faults or severe load unbalances are occurred on the system. Because DGs interconnected to the grid can contribute fault currents and make bidirectional power flows on the system, fault currents from DGs can cause an interference of relay operation. A directional over current relay(DOCR) can determine the direction of power flow whether a fault occurs at the source side or load side through detecting the phases of voltage and current simultaneously. However, it is identified in this paper that the contributed fault current(Ifdg) from the ground source when was occurred to contribute single-line-to-ground(SLG) fault current, has various phases according to the distances from the ground source. It means that the directionality of Ifdg may not be determined by simply detecting the phases of voltage and current in some fault conditions. The magnitude of Ifdg can be estimated approximately as high as 3 times of a phase current and its maximum is up to 2,000 A depending on the capacity of generation facilities. In order to prevent malfunction of relay and damage of DG facilities from the contribution of ground fault currents, Ifdg should be limited within a proper range. Installation of neutral ground reactor (NGR) at a primary neutral of interconnection transformer was suggested in the paper. Capacity of the proposed NGR can be adjusted easily by controlling taps of the NGR. An algorithm for unidirectional relay was also proposed to prevent the malfunction of relay due to the fault current, Ifdg. By the algorithm, it is possible to determine the directionality of fault from measuring only the magnitude of fault current. It also implies that the directionality of fault can be detected by unidirectional relay without replacement of relay with the bidirectional relay.