• 제목/요약/키워드: Power System Analysis

검색결과 9,426건 처리시간 0.036초

제주지역 풍력발전량 실시간 감시 시스템 구축에 관한 연구 (A Study on the Real-Time Monitoring System of Wind Power in Jeju)

  • 김경보;양경부;박윤호;문창은;박정근;허종철
    • 한국태양에너지학회 논문집
    • /
    • 제30권3호
    • /
    • pp.25-32
    • /
    • 2010
  • A real-time monitoring system was developed for transfer, receive, backup and analysis of wind power data at three wind farm(Hang won, Hankyung and Sung san) in Jeju. For this monitoring system a communication system analysis, a collection of data and transmission module development, data base construction and data analysis and management module was developed, respectively. These modules deal with mechanical, electrical and environmental problem. Especially, time series graphic is supported by the data analysis and management module automatically. The time series graphic make easier to raw data analysis. Also, the real-time monitoring system is connected with wind power forecasting system through internet web for data transfer to wind power forecasting system's data base.

전력수급 종합시스템 현장적용 (Implementation of Highly Integrated Total Energy System)

  • 박시우;윤용범;남재현;추진부;최봉수;이효상;김준환;류성호;한승구;백웅기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1525-1525
    • /
    • 1999
  • The main purpose of HITES(Highly Integrated Total Energy System) is to build and develop an integrated energy system for power system operational planning and analysis which consists of load forecast, economic generation schedule, stability analysis and relational database system. The HITES can be utilized to supply a stable electric power and operate KEPCO's power system facilities economically. This system was put into operation in 1999. This paper describes the main feature of the HITES, main functions, numerical methods adopted in this system and network configuration.

  • PDF

변전소 자동화 환경에서 웹 기반 전기품질 감시 시스템 (A web-based power quality monitoring system in the Substation Automation System)

  • 박동호;임성정;신재항;임성일;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.378-380
    • /
    • 2004
  • Along with the increase of the importance of power quality, many various systems are dedicated in the analysis of power quality nowadays. But there still exists the same problems for realizing such kind of analysis systems well. One is the customization of the power quality measure devices; The other is an economic problem. This paper presents the usefulness and the advantage of the ICD (Intelligent Electronic Device) as the measure device of power quality And this paper detailedly describes the development procedure of web-based power quality monitoring system through ActiveX controls. Now this power quality monitoring system is already applied to the substation automation system.

  • PDF

사출성형기 유압시스템의 특성 검토를 위한 해석 모델 개발 (Development of Analysis Model for Characteristics Study of Fluid Power Systems in Injection Molding Machine)

  • 장주섭
    • 유공압시스템학회논문집
    • /
    • 제8권4호
    • /
    • pp.1-8
    • /
    • 2011
  • Injection molding machine is the assembly of many kinds of mechanical and fluid power part and electro-electronic control system. From in these, fluid power is a part where becomes the first core of this machine. Fluid power systems of injection molding machine are modelled and analyzed using a commercial program AMESim. The analysis model which is detailed about the parts applied a publishing catalog data. Sub system models which is divided according to functional operation are made and its analysis results shows how design parameters work on operational characteristics like displacement, pressure, flow rates at each node and so on. Total fluid power circuit model is also made and analyzed. The results made by analysis will be used design of fluid power circuit of injection molding machine.

FTA를 이용한 교류전철변전소의 신뢰도 분석 (Reliability Analysis of AC Railway Substation by using FTA)

  • 구본희;차준민;김형철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.248-254
    • /
    • 2008
  • Electric railway system consists of traction power system, rolling stock, track, and overhead line system. A railway substation transforms the electric power transmitted from a electric power company and supply it to the railway power system for the operation of traction system.. It is very important to prevent a possible accident and keep the security of electric power system. This paper proposes a reliability analysis of AC railway substation by using Fault Tree Analysis(FTA). Failure rates of each equipment of railway substation are used to evaluate the reliability of railway substation. The analyzed results can be used to improve the system reliability. FTA is performed by the commercialized program of Relex(Ver. 7.7).

  • PDF

Modeling of a Variable Speed Wind Turbine in Dynamic Analysis

  • Kim, Seul-Ki;Kim, Eung-Sang;Jeon, Jin-Hong
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권2호
    • /
    • pp.51-57
    • /
    • 2004
  • This paper describes the dynamic performance of a variable speed wind turbine system responding to a wide variety of wind variations. Modeling of the wind generation using power electronics interface is proposed for dynamic simulation analysis. Component models and equations are addressed and their incorporations into a transient analysis program, PSCAD/EMTDC are provided. A wind model of four components is described, which enables observing dynamic behaviors of the wind turbine resulting from wind variations. Controllable power inverter strategies are intended for capturing the maximum power under variable speed operation and maintaining reactive power generation at a pre-determined level for constant power factor control or voltage regulation control. The components and control schemes are modeled by user-defined functions. Simulation case studies provide variable speed wind generator dynamic performance for changes in wind speed

PSCAD/EMTDC를 이용한 측정기반의 부하모델링 연구 (A Study On Measurement-based Load Modeling Using PSCAD/EMTDC)

  • 이경상;박래준;송경빈
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1079-1085
    • /
    • 2011
  • To supply electrical power with high quality, the power system must be optimized in many ways such as planning, control and management. In order to optimize the power system, the analysis of the power system is necessary. The elements of the power system require an accurate model to analysis of the power system. The components of the power systems such as generators, transformers and transmission lines have been studied and researched a lot in their modeling and very sophisticated models have been proposed. However, in case of load in-depth studies on the exact model are required. In this paper, measurement-based load modeling method using real-time measured data is proposed in various methods to reflect the characteristics of the load. To prove the validity of the proposed method, PSCAD/EMTDC program is used to configure the power system and measurement data according to the various failures are used to study on load modeling.

배전계통에 초전도 전류 제한기 적용시 보호협조 분석 (Analysis on the Protective Coordination in Power Distribution System with Superconducting Fault Current Limiter)

  • 안재민;김진석;문종필;임성훈;김재철;김철환;현옥배
    • 전기학회논문지
    • /
    • 제57권5호
    • /
    • pp.755-760
    • /
    • 2008
  • The increase of fault current due to larger power demand has caused the capacity of power machines in grid to increase. To protect the power system effectively from the larger fault current, several countermeasures have been proposed. Among them, the superconducting fault current limiter (SFCL) has been expected as one of the most effective solutions. Therefore, to introduce SFCL into power distribution system, the analysis on protection in power distribution system with SFCL is essential. In this paper, the problems of the protective coordination in power distribution system with SFCL were described.

Simulation and Experimentals of a Bi-Directional Converter with Input PFC on SRM System

  • Maged Maged N.F.
    • Journal of Power Electronics
    • /
    • 제6권2호
    • /
    • pp.121-130
    • /
    • 2006
  • This paper presents the performance and efficiency of a drive system incorporating a switched-reluctance motor (SRM) with input power factor correction (PFC). The proposed system consists of a PFC, bi-directional converter, an inverter, and a SRM operating as based voltage source drives (VSD). First, theoretical analysis is made for each identified mode of operation in the drive system. This is followed by comparing the performance of the SRM drive system with and without a PFC circuit. The losses are also calculated for both systems and overall efficiency. Experimental results are presented to prove the theoretical analysis.

전력 역변환장치 주요발열부의 열 저감 시스템 변위에 따른 냉각 특성해석 (Analysis of Cooling Characteristics according to Heating Reduction System Displacement of Major Heating Region on Power Inverter)

  • 김민석;김용재
    • 한국전자통신학회논문지
    • /
    • 제10권2호
    • /
    • pp.261-266
    • /
    • 2015
  • 신재생에너지용 발전 시스템은 모듈, 직류 전력을 교류 전력으로 변환시키는 전력 역변환장치, 전력흐름을 제어하고 계통 연계를 담당하는 제어장치로 구성된다. 이러한 시스템은 일사량이 많은 여름철 및 낮 시간에 가장 많은 직류전력을 생산하지만 계통의 연계를 위해 필수적인 전력 역변환장치는 특정 온도 이상으로 상승하면 효율이 급격히 감소하게 된다. 따라서 열전소자를 부착한 열 저감 시스템을 제안하고 가장 발열이 심한 구간을 선정하여 사용개수 및 위치에 따른 온도 특성 해석을 통해 최적 모델을 도출하고자 한다.