• Title/Summary/Keyword: Power Saving Control

Search Result 407, Processing Time 0.027 seconds

Current Status and Future of Vermicomposting Industries in Korea (지렁이 퇴비화 산업 현황 및 향후과제)

  • Kim, Jong-Oh;Lee, Chang-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.2
    • /
    • pp.52-57
    • /
    • 2001
  • ln this study, the questionnaire survey was performed to obtain the basic data on current situations and challengeable aspects of vermicomposting industries. The questionnaire contained the four main categories such as vermicomposting facilities, feeling marerials, earthworm breeding and cast handling. The results was summarized as followings: 1. Vermicomposting facilities area was becoming larger, and earthworm feed was also expending to various organic sludges. These trends showed that Vermicomposting is being enlightened to treat and recycle the organic wastes in Korea. 2. Present Vermicomposting technology needs the broad land. Because of the high cost of land in Korea, the land saving technology such as multistage must be needed. And present operation practices are mostly based on human power, mechanization and automation is needed. Also, present control practices are based on individual experience need the scientific base control system. 3. Considering situations of organic wastes management in Korea, the technical development and the practical improvement of Vermicomposting as the waste recycling will be needed.

  • PDF

TAS: TCP-Aware Sub-layer over IEEE 802.11-based wireless LANs (IEEE 802.11 기반 무선랜에서 TCP 인진서브 계층 TAS)

  • Choi, Nak-Jung;Jung, Ha-Kyung;Ryu, Ji-Ho;Seok, Yong-Ho;Choi, Yang-Hee;Kwon, Tae-Kyoung
    • Journal of KIISE:Information Networking
    • /
    • v.33 no.5
    • /
    • pp.355-368
    • /
    • 2006
  • This paper introduces a new split-TCP approach for improving TCP performance over IEEE 802.11-based wireless LANs. TCP over wireless LANs differently from wired networks is not aggressive, which is a fundamental reason for poor performance. Therefore, we propose TAS (TCP-Aware Sub-layer) to migigate this problem. Our scheme extends the split-connection approach that divides a connection into two different connections at a split point such as an access point (AP). Using TAS, a wireless node emulates TCP ACK packets using MAC ACK frames, instead of receiving real TCP ACK packets. We compared TAS with both normal TCP and I-TCP (Indirect TCP) by NS2 simulation. Results show that TAS achieves higher throughput, more fair resource allocation and, in power-saving mode, shorter delays.

A Study on Fisheries Resource Management Under the Rate Payment System - In Case of Large Trawl Fisheries - (비율(보합) 급제하에서 어업(자원)관리에 관한 연구 - 대형기선저인망어업을 중심으로 -)

  • Park Seong-Kwae
    • The Journal of Fisheries Business Administration
    • /
    • v.36 no.3 s.69
    • /
    • pp.1-24
    • /
    • 2005
  • Korean fishery wage system has been evolved with the different titles. However, Since the law of fishing crew was enacted in 1984, the fishery wage system has been established as a rate system, which is a legal term. The present rate system in practice shows various contents and modalities, depending on fisheries and regions, but the fisheries of large trawl cooperative employ a rate system of fixed plus rate wage. However, such change did not transform basically the properties of pure rate scheme. As well known, fishing vessel owners face an awful lot of difficulty in managing and controlling effectively the production process because fishing activities are carried out in the seas remote from the land. Thus, it tend to be inevitable for vessel owners to employ a rate system to induce fishermen's positive motivation for promoting productivity and saving operating costs. However, the rate system has worked out as a driving force, which induce an increase in production more strongly under the expansion of vessel numbers and power and the keener competition of fishing activities. Even though the control mechanism of fishing instruments are well established, fishermen become naturally to have an incentive to increase their fishing effort for maximizing production since they are able to raise their shares by maximizing the quantity harvested. Thus, as far as the rate system exists, fisheries administration may have much difficulty in realizing its fishery management goals only through vessel reduction and fishing gear regulations. Also, under the rate system fishery management authority may be in face of a serious dilemma between the spontaneous rate system and vessel reduction policy. If the realistic aspect of the rate system is recognized and resource restoration and profit promotion are main policy goals, it is necessary to develop effective ways to control vessel owners' and fishermen's production-maximizing motives at an appropriate level. From this point of view, it seems reasonable to introduce TAC system by species or by fisheries into the existing fishery system. The research results suggest that if the fisheries administration could understand clearly the spontaneous fisheries wage system, it would know the norm of TAC and the basic reasons for illegal fishing activities and thus it would be able to develop and implement more realistic resource management policies.

  • PDF

Development of Digital Solder Station Based on PID Controller (PID 제어기를 이용한 전기인두기의 온도 제어 시스템 개발)

  • Oh, Kab-Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.866-872
    • /
    • 2010
  • In this paper, we developed a digital soldering station based on PID controller, which supply stable power by controlling the current of heater of soldering iron. The proposed system designed PID controller to converge quickly to the set up temperature by user, and regain the lost of heat by external factors quickly. PID controller, designed by Ziegler-Nichols' tuning method, decides triac's trigger timing using setting temperature and present temperature to control the phase of AC 24V power that supply to the heater. Also, we give the function that shows present temperature and setting temperature of iron, and working time by graphic LCD. And during the rest time, we decided the power saving and extension of iron tip by dropping to the optimal temperature. Two experiments had implemented in $25^{\circ}C$ laboratory to confirm the performance of proposed method. The first experiment took 12sec, 13sec, 16sec, 18sec, reaching to $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$, $480^{\circ}C$ respectively which result showed shorten of rising time than previous method. In the loading experiment of $300^{\circ}C$, $400^{\circ}C$, $480^{\circ}C$ steady state showed temperature drop of $3.8^{\circ}C$, $4.1^{\circ}C$, $4.5^{\circ}C$ which result showed the low temperature deviation than previous method.

A study on lighting system for LED color temperature control using wireless communication and smartphone (무선 통신과 스마트폰을 이용한 LED 색온도 제어 조명 시스템에 관한 연구)

  • Hong, Young-Jin;Lim, Soon-Ja;Lee, Wan-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.72-77
    • /
    • 2017
  • Lighting systems in modern society has been developed using a combination of IT technology and LED lighting for the purpose of bringing about changes in human-centered natural lighting and to take advantage of the efficient management and energy saving of LED lighting. In this paper, we propose an LED lighting control system that can control the color temperature and brightness of LED lighting composed of 3000K Warm LEDs and 6000K Cool LEDs by using an Arduino Due and wireless communication technology such as Bluetooth and Zigbee. The Arduino Due allows the color temperature of the lighting to be adjusted in several steps by controlling the duty rate and enables many lights to be controlled using Zigbee communication capable of 1: N multiple communication. By using Bluetooth communication, it is possible to easily control the LED lighting by means of a smartphone application, thereby enhancing the convenience for the user. The wireless communication based LED lighting control system implemented in this study cannot only provide human-centered lighting through its color temperature control from 3067K to 5960K and illumination control, but can also reduce the power consumption and be used as a natural-friendly lighting system.

Effects of Lettuce Cultivation Using Optical Fiber in Closed Plant Factory (폐쇄형 식물공장내 태양광 파이버를 이용한 상추 재배효과)

  • Lee, Sanggyu;Lee, Jaesu;Won, Jinho
    • Journal of Bio-Environment Control
    • /
    • v.29 no.2
    • /
    • pp.105-109
    • /
    • 2020
  • This study was conducted to the improvement of solar light-based artificial light supply system and effect of lettuce cultivation. The artificial light supply system was consisted of units such as light source, power, system measurement and controller. The light source supply was composed of a solar transmitter and an LED lamp. The power supply consisted of an leakage breaker, SMPS, LED controller and relay. The solar transmitter was made of a quartz optical fiber with optimal light transmission. Artificial light used white lamp among LEDs. System measurement and control consisted of touch screen, Zigbee communication module and light quantity sensor. The results of test confirmed that the LED light is automatically activated when the intensity measured by the light intensity sensor is 200 μmolm-2s-1 or less. Moreover, the leaf length, root length, chlorophyll content and root fresh weight of optical fiber treatment was hight than LED lamp treatment. Therefore, it can be inferred that the energy-saving solar light collector device can be effective in the indoor lettuce production. However, the use of LED lamp is also recommended to assure the availability of sufficient sunlight in cloudy and rainy days.

Application Effect of Heating Energy Saving Package on Venlo Type Glasshouse of Paprika Cultivation (파프리카 재배 벤로형 유리온실에서 난방에너지 절감 패키지 기술 적용효과)

  • Kwon, Jin Kyung;Jeon, Jong Gil;Kim, Seung Hee;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.225-231
    • /
    • 2016
  • Glasshouse heating package technologies to improve energy usage efficiency in winter were developed. Heating package was composed of the ground water source heat pump with heating capacity of 105kW, the aluminum multi-layer thermal curtain with six layers of different materials and the root zone local heater with XL pipes of ${\phi}20mm$. Venlo type glasshouse($461m^2$) with the heating package was compared with the same type and area control glasshouse with the light oil boiler, the usual non-woven fabric thermal curtain with respect to the glasshouse inside temperature, relative humidity, crop growth, and heating energy consumption. The results of test in paprika cultivation glasshouses showed that the air temperature inside glasshouse with aluminum multi-layer thermal curtain was maintained $2.2^{\circ}C$ higher than that of control glasshouse in un-heating night time and the temperature in bed with root zone local heating was $4.7^{\circ}C$ higher than that in bed without local heating. Average heating coefficient of performance(COP) of the ground water source heat pump used in paprika cultivation was 3.7 and the glasshouse inside temperature was maintained at $21^{\circ}C$ of heating set up temperature. The heating energy consumptions per 10a were measured at 14,071L of light oil and 364kWh of electric power for the control glasshouse and 35,082kWh for the glasshouse applied heating package. As results, the heating cost of the glasshouse applied heating package was 87 percent lower than that of control glasshouse. The growths of paprika in glasshouses of control and applied heating package did not show any significant difference.

A Study on the Development of the Engine Room Fan Control System and ERFCS Algorithm for Ships Energy Saving (선박 에너지 절감을 위한 기관실 팬 제어 시스템 구축 및 알고리즘에 관한 연구)

  • Kang, Young-Min;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.6
    • /
    • pp.642-648
    • /
    • 2015
  • Recently, there have been many studies pertaining to reducing energy consumption on ships. As part of those studies, the energy consumption of ships can be reduced by understanding and controlling the varying loads, excluding fixed loads. In existing ships, engine room fans are usually operated based on the actual experience of the crew without any special guidelines. To realize energy reduction, we investigate the characteristics of engine-room fans, and we propose an energy-management system called the engine room fan control system (ERFCS) and the ERFCS algorithm. The ERFCS controls the fan speed depending on the temperature and pressure, where one to four fans are operated depending on changes in the load. In addition, the minimum rotation speed of the engine-room fan was limited to 50% to prevent the surging phenomenon, which is due to fan damage or low pressure resulting from mechanical friction or heating at low fan speeds. We develop a fan control system simulation model using LabVIEW that is based on the proposed algorithm and ISO 8861. Finally, we perform simulations to confirm that operation of the proposed fan control system is possible using only 46.4% of the power required by the existing method.

Realization of an IEEE 802.11g VoWLAN Terminal with Support of Adaptable Power Save and QoS During a Call (통화 중 적응적 Power Save와 QoS 지원이 가능한 IEEE B02.11g VoWLAN 단말기 구현)

  • Kwon, Sung-Su;Lee, Jong-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.10A
    • /
    • pp.1003-1013
    • /
    • 2006
  • There is a serious problem in an 802.11g VoWLAN (Voice over Wireless LAN) terminal that talk time is less than 30% compared with an 802.11b terminal. It is almost impossible to achieve talk time level of the 802.11b MAC transmission method because IEEE 802.11g uses OFDM modulation, which is a kind of multi-carrier method and OFDM transmission speed is 54 Mbps faster than normal modulation. In this paper, a new concept of a Holdover time as a power saving method during a call with 802.11g terminal is suggested for the first time. Increase in the number of engaged terminals as a result of holdover time causes to QoS problem because of the increase in the number of back-off and then contention window. In this paper, to solve the QoS problem, a new approach is suggested such that when in down lint the sequence number of 802.11 G.711 is analyzed in the MAC of the terminal and then the Hold over time depending on loss rate is changed. Also, consumption of an electric current of 802.11b/g and MAC parameter's performance due to busy traffic caused by increase in the number of terminal are analyzed and then real data using VQT and Airopeek are analyzed.

Particle Swarm Optimization-Based Peak Shaving Scheme Using ESS for Reducing Electricity Tariff (전기요금 절감용 ESS를 활용한 Particle Swarm Optimization 기반 Peak Shaving 제어 방법)

  • Park, Myoung Woo;Kang, Moses;Yun, YongWoon;Hong, Seonri;BAE, KUK YEOL;Baek, Jongbok
    • Journal of IKEEE
    • /
    • v.25 no.2
    • /
    • pp.388-398
    • /
    • 2021
  • This paper proposes a particle swarm optimization (PSO)-based peak shaving scheme using energy storage system (ESS) for electricity tariff reduction. The proposed scheme compares the actual load with the estimated load consumption, calculates the additional output power that the ESS needs to discharge additionally to reduce peak load, and adds the input. In addition, in order to compensate for the additional power, the process of allocating power to the determined point is performed, and an optimization that minimizes the average of the load expected at the active power allocations using PSO so that the allocated value does not affect the peak load. To investigated the performance of the proposed scheme, case study of small and large load prediction errors was conducted by reflecting actual load data and load prediction algorithm. As a result, when the proposed scheme is performed with the ESS charge and discharge control to reduce electricity tariff, even when the load prediction error is large, the peak load is successfully reduced, and the peak load reduction effect of 17.8% and electricity tariff reduction effect of 6.02% is shown.