• Title/Summary/Keyword: Power Number

Search Result 5,765, Processing Time 0.045 seconds

Intelligent Reclosing Scheme to reduce a Damage of Power Equipments (전력설비 피해 감소를 위한 지능형 재폐로방식에 관한 연구)

  • 임성정;김재철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.1
    • /
    • pp.112-117
    • /
    • 2001
  • This paper presents an intelligent reclosing scheme to reduce a damage of power equipments in power distribution systems. As the number of reclosing shot increases, an power supply reliability is improved, but an impact of electric facilities by fault currents is accumulated. The proposed scheme determines the number of reclosing shots and its intervals according to ilie magnitude of fault current. Therefore, this scherre reduces a harm of electric facilities and muntains the power supply reliability. Case studies is performd to verify the effectiveness of the proposed scheme using field operation data.

  • PDF

Development of Conversion Program by EMS Data Acquisition (EMS 실계통 데이터 활용을 위한 자동변환 프로그램 개발)

  • Oh, Sung-Kyun;Shin, Man-Cheol;Kim, Kern-Joong;Choi, Young-Min;Kang, Boo-Il;Han, Hei-Cheon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.410-411
    • /
    • 2007
  • In this paper describe for development of conversion program by EMS data acquisition. Currently EMS output data has a arbitrary bus number and incorrect bus name. It is need to delvelop converting program for using this data to analysis real power system. Conversion consist of bus number and bus name convert, machine's MBASE, X''d, Machine ID, Area, Zone Code, adding tie-line and remove small genererator that was not consider in transient stability analysis. As result of this work, the efficiency of power system analysis is increase and the result input data is used for many analysis applications.

  • PDF

SOME NEW RESULTS ON POWER CORDIAL LABELING

  • C.M. BARASARA;Y.B. THAKKAR
    • Journal of applied mathematics & informatics
    • /
    • v.41 no.3
    • /
    • pp.615-631
    • /
    • 2023
  • A power cordial labeling of a graph G = (V (G), E(G)) is a bijection f : V (G) → {1, 2, ..., |V (G)|} such that an edge e = uv is assigned the label 1 if f(u) = (f(v))n or f(v) = (f(u))n, For some n ∈ ℕ ∪ {0} and the label 0 otherwise, then the number of edges labeled with 0 and the number of edges labeled with 1 differ by at most 1. In this paper, we investigate power cordial labeling for helm graph, flower graph, gear graph, fan graph and jewel graph as well as larger graphs obtained from star and bistar using graph operations.

Performance Analysis of a Cross Flow Hydro Turbine by Runner Blade Number (소수력발전용 횡류수차의 러너 블레이드 깃수에 따른 성능해석)

  • Choi, Young-Do;Jin, Chang-Fu;Lim, Jae-Ik;Kim, You-Taek;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.698-706
    • /
    • 2008
  • Performance improvement of Small hydro turbine is a very important subject to solve in the stage of introduction and development of the turbine. Cross-flow hydro turbine should be also studied more in detail for the turbine performance in order to extend the sites of application. In order to improve the turbine performance, the effect of the turbine shape on the turbine performance should be examined. Therefore, the effect of runner blade number on the turbine performance is investigated by use of a commercial CFD code. The results show that runner blade number gives remarkable effect on the efficiency and output power of the turbine. Pressure on the surface of the runner blade changes considerably by the blade number at Stage 1, but relatively small change of velocity distribution occurs in the flow passage.

Advanced Cascade Multilevel Converter with Reduction in Number of Components

  • Ajami, Ali;Oskuee, Mohammad Reza Jannati;Mokhberdoran, Ataollah;Khosroshahi, Mahdi Toupchi
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.127-135
    • /
    • 2014
  • In this paper a novel converter structure based on cascade converter family is presented. The suggested multilevel advanced cascade converter has benefits such as reduction in number of switches and power losses. Comparison depict that proposed topology has the least number of IGBTs among all multilevel cascade type converters which have been introduced recently. This characteristic causes low cost and small installation area for suggested converter. The number of on state switches in current path is less than conventional topologies and so the output voltage drop and power losses are decreased. Symmetric and asymmetric modes are analyzed and compared with conventional multilevel cascade converter. Simulation and experimental results are presented to illustrate validity, good performance and effectiveness of the proposed configuration. The suggested converter can be applied in medium/high voltage and PV applications.

Number of Elements in Smart Antenna System effects on both Perfect and Imperfect Power Control or Reverse Link of CDMA Cellular System

  • Uthansakul, Peerapong;Uthansakul, Monthippa
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1956-1959
    • /
    • 2002
  • Power control (PC) on the reverse link of CDMA cellular system is important to increase system capacity. PC eliminates fluctuations in the received signal level and hence reduces the required signal-to-interference ratio. However, both perfect PC and imperfect PC depend on number of interferences as number of users, which by using smart antenna system can decrease number of interferences in any directions except interferences from the main beam direction. In this paper , number of elements in smart antenna system, which directly relates to the main beam pattern, is studied to find the effects on the outage probability , bit energy-to-interference density ratio (Eb/Io) and the capacities of both perfect and imperfect PC.

  • PDF

Performance Analysis of PAPR and LS Estimation in OFDM Systems

  • Khan, Latif Ullah
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.3
    • /
    • pp.135-141
    • /
    • 2014
  • The inherent feature of the highly efficient spectrum usage has made Orthogonal Frequency Division Multiplexing (OFDM) preferable for Communication Standards. This study evaluated the performance of a Least Square (LS) estimator for a comb-type pilot insertion scheme over a fast fading Rayleigh channel. A High Peak-to-Average Power Ratio (PAPR) is one of the major downsides of the OFDM. The effects of an increase in the number of subcarriers on PAPR and the performance of the LS Estimator were studied. Increasing the number of subcarriers while keeping the pilots overhead constant resulted in improved performance of the LS estimator but the PAPR increased with increasing number of subcarriers. Therefore some trade-off between the number of subcarriers and the performance of the OFDM system is needed. The Mean Square Error (MSE) expression was also derived for the LS estimator in the case of a comb-type pilot arrangement. The MSE expression clearly explains the effects of the number of subcarriers on the performance of the LS estimator.

NORDHAUS-GADDUM TYPE RESULTS FOR CONNECTED DOMINATION NUMBER OF GRAPHS

  • E. Murugan;J. Paulraj Joseph
    • Korean Journal of Mathematics
    • /
    • v.31 no.4
    • /
    • pp.505-519
    • /
    • 2023
  • Let G = (V, E) be a graph. A subset S of V is called a dominating set of G if every vertex not in S is adjacent to some vertex in S. The domination number γ(G) of G is the minimum cardinality taken over all dominating sets of G. A dominating set S is called a connected dominating set if the subgraph induced by S is connected. The minimum cardinality taken over all connected dominating sets of G is called the connected domination number of G, and is denoted by γc(G). In this paper, we investigate the Nordhaus-Gaddum type results for the connected domination number and its derived graphs like line graph, subdivision graph, power graph, block graph and total graph, and characterize the extremal graphs.

The Optimum Configuration of Vehicle Parking Guide System based on Ad Hoc Wireless Sensor Network

  • Lim, Myoung-Seob;Xu, Yihu;Lee, Chung-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.3
    • /
    • pp.199-203
    • /
    • 2011
  • The wireless sensor network (WSN) based on ad hoc network is applied to vehicle parking guide system without parking guide man at area or building with large scale of parking lots. The optimum number of cluster heads was derived for getting the minimum power consumption as well as time delay. Through the theoretical analysis of power consumption and time delay with the number of cluster heads in wireless sensor network, it was found that there exists the minimum point in the variation of power consumption and time delay according to the number of cluster heads.

Effect of Axial-Layered Permanent-Magnet on Operating Temperature in Outer Rotor Machine

  • Luu, Phuong Thi;Lee, Ji-Young;Kim, Ji-Won;Chun, Yon-Do;Oh, Hong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2329-2334
    • /
    • 2018
  • This paper discusses the thermal effect of the number of permanent-magnet (PM) layers in an outer rotor machine. Depending on the number of axial-layer of PM, the operating temperature is compared analytically and experimentally. The electromagnetic analysis is performed using 3-dimensional time varying finite element method to get the heat sources depending on axial-layered PM models. Then thermal analysis is conducted using the lumped-parameter-thermal-network method for each case. Two outer rotor machines, which have the different number of axial-layer of PM, are manufactured and tested to validate the analysis results.