• 제목/요약/키워드: Power Monitoring Systems

검색결과 765건 처리시간 0.034초

발전용 터빈 윤활계통 기계시스템의 상태진단기술 개발연구 (Study on the Development of Condition Monitoring Technology for Turbine Lubricating Systems in Power Plants)

  • 신규식;김재평;남창현;백수곤;권오관;안효석;윤의성;손동구
    • Tribology and Lubricants
    • /
    • 제10권4호
    • /
    • pp.51-58
    • /
    • 1994
  • Condition monitoring technology has recently been received much attention in the light of its significance on the maintenance of complex machineries such as turbines in power plants. Currently, turbines in power plants are maintained by scheduled overhaul based on the manufacturer's recommendations and the utility's experience. Although this preventive maintenance is known to be very effective, operators have less access to identify failure of elements when it happens between overhaul period. Therefore, in this study, a development of a on-line condition monitoring system through wear debris analysis of lubricating oils is aimed with a view to detecting abnormal wear behaviour of bearings and other wet-components at an early stage, allowing better outage scheduling and minimizing forced outages. For field application purposes, the on-line system developed was installed on the turbine of the No.4 unit at Ulsan Power Plant and its performance has been evaluated on site.

SIEMENS DCS 환경에서 화력발전소 성능감시 시스템 구현 (Implementation of Performance Monitoring System for Thermal Power Plant in SIEMENS DCS)

  • 김승민;문태선;조창호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.37-37
    • /
    • 2000
  • This paper introduces the Performance Monitoring System(PMS) in a thermal power plant. The purpose of the PMS is to offer the operator current performance information of plant which could be an index of plant status or information to improve plant efficiency. The PMS of Bukcheju thermal power plant unit #2&3 is implemented under the SIEMENS DCS which supplies about 150 function blocks for performance calculation and all measured signals. The performance of unit, boiler, turbines, feedwater heaters, condenser, airpreheaters, feedwater pumps will be monitored and updated for every 5 minutes in PMS of Bukcheju TPP.

  • PDF

Laboratory Environment Monitoring: Implementation Experience and Field Study in a Tertiary General Hospital

  • Kang, Seungjin;Baek, Hyunyoung;Jun, Sunhee;Choi, Soonhee;Hwang, Hee;Yoo, Sooyoung
    • Healthcare Informatics Research
    • /
    • 제24권4호
    • /
    • pp.371-375
    • /
    • 2018
  • Objectives: To successfully introduce an Internet of Things (IoT) system in the hospital environment, this study aimed to identify issues that should be considered while implementing an IoT based on a user demand survey and practical experiences in implementing IoT environment monitoring systems. Methods: In a field test, two types of IoT monitoring systems (on-premises and cloud) were used in Department of Laboratory Medicine and tested for approximately 10 months from June 16, 2016 to April 30, 2017. Information was collected regarding the issues that arose during the implementation process. Results: A total of five issues were identified: sensing and measuring, transmission method, power supply, sensor module shape, and accessibility. Conclusions: It is expected that, with sufficient consideration of the various issues derived from this study, IoT monitoring systems can be applied to other areas, such as device interconnection, remote patient monitoring, and equipment/environmental monitoring.

리튬이온 배터리의 사용 특성 분석을 위한 무선 모니터링 시스템 설계 (Design of a Wireless Monitoring System for Analyzing the Usage Characteristics of Lithium-ion Batteries)

  • 박재용;정양희;강성준
    • 한국전자통신학회논문지
    • /
    • 제19권5호
    • /
    • pp.1067-1074
    • /
    • 2024
  • 여수산업단지 등과 같은 대규모 생산설비에서는 다양한 감시 장치들이 가동되고 있고 이들 장치의 운전을 위한 전원 설비로써 열악한 환경에 대응하기 위한 저전력 리튬이온 배터리를 내장한 방호장치를 사용하고 있다. 본 연구에서는 이들 리튬이온 배터리의 사용 특성 분석을 위한 무선 모니터링 시스템을 설계, 구현하고 이들 시스템을 이용하여 배터리를 포함하는 방호장치의 온도, 습도 및 방호장치 내의 배터리 충방전에 의한 가스 발생과 배터리의 특성 변화를 무선으로 상시 모니터링 할 수 있도록 하였다. 이들 시스템을 통하여, 산업단지 내의 감시장치 등에 필요한 배터리의 안정적인 관리와 전원을 공급함으로써 공장 생산설비의 효율적인 운영과 관리 체계를 수립하는데 기여하고자 한다.

광파이버 누수센싱 시스템 개발에 관한 연구 (A Study on the Development of Optical-Fiber Water Leakage Sensing System)

  • 김영복
    • 동력기계공학회지
    • /
    • 제16권6호
    • /
    • pp.86-91
    • /
    • 2012
  • A multi purpose environmental monitoring system has been developed as a commercially available standard using the techniques which are FBG(Fiber Bragg Grating), Hetero-core spliced fiber optic sensor and etc, for the purposes of monitoring large scaled structures and preserving natural environments. The monitoring system has been tested and evaluated in a possible outdoor condition in view of the full scaled operation at actual sites to be monitored. Additionally, the developed systems in the previous works conveniently provided us with various options of sensor modules intended for monitoring such physical quantities as displacement, distortion, pressure, binary states, and liquid adhesion. In this paper, we extend the previous results to a water leakage detection problem and develop a sensing system as a result. By the experimental study, it is verified that multi-point leakage detection is possible using single line optical fiber.

전력용 변압기 예방진단 시스템의 실 계통 적용 연구 (A study on field test of diagnostic Monitoring System for Power Transformers)

  • 김용한;이창용;황보승욱;신용택;박귀철;박균수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.91-93
    • /
    • 2004
  • This study presents recent trends on the on-line monitoring and diagnostic systems for oil-immersed transformers. Specially, our system on Yeo Su thermal power plant is introduced for high sensitivity and accuracy of ours. It is combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

Development of Power Quality Management System with Power Quality Diagnosis Functions

  • Chung Il-Yop;Won Dong-Jun;Ahn Seon-Ju;Kim Joong-Moon;Moon Seung-Il;Seo Jang-Cheol;Choe Jong-Woong;Jang Gil-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.28-34
    • /
    • 2006
  • Recently, in accordance with the development of IT technology, it is prevalent for power quality monitors to be connected to each other via networks and share their data because such networks provide system-wide insights to customers concerning power quality. Those systems can alarm and display power quality events for the convenience of customers. However, if a power quality event occurs, it is difficult for customers to determine its cause and solution because the systems do not provide appropriate power quality diagnosis functions. The power quality management system presented in this paper has been developed to provide customers with various power quality diagnosis functions so that they can cope well with power quality problems with the right measure in the right place. This paper presents the structure and functions of the developed power quality management system and shows some results of the power diagnosis functions.

전자식 전력량계와 무선모듈을 이용한 전력품질 표시 및 모니터링 (Power Quality Monitoring with Electronic Watt-hour meter and Wireless communication module)

  • 정득일;손영대
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.172-174
    • /
    • 2007
  • An electronic watt-hour meter with high-precision measurement technology can provide many valuable metering data of a real-time system measurements, such as per-phase voltage, ampere, active power, reactive power, apparent power, power factor, and system frequency. Also many of accumulated metering data such as active energy, reactive energy, apparent energy, and load profile can be gettable from an electronic watt-hour meter[1]. This paper presents an approach of the small-sized AMR (Automatic Meter Reading) that provides customers with a very valuable electrical service. This AMR service transmits lots of a valuable metering data by using ZigBee communication module, so that users resided in their premises can use the information to audit a power quality and improve their electrical conditions by using the PQ monitoring device equipped with ZigBee receiver. This PQ monitoring device shows metering data on LCD and transmits to the PC through an internal network. Also, the device can keep the valuable meter data into a built-in non-volatile memory. The final goal of this paper is to better understand the power quality of electrical systems and offer the power qualify information for the convenience of all power consumers.

  • PDF

Zigbee통신을 이용한 전력변환기기의 DC Bus 커패시터의 온라인 원격 고장진단 시스템 (On-line Remote Diagnosis System for DC Bus Capacitor of Power Converters Using Zigbee Communication)

  • 정완섭;손진근
    • 전기학회논문지P
    • /
    • 제64권1호
    • /
    • pp.29-34
    • /
    • 2015
  • DC bus electrolytic capacitors are used in variety of equipments as smoothing element of the power converters because it has high capacitance for its size and low price. It is responsible for frequent breakdowns of many static converters and inverter drive systems. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure of power converter. In this paper, the on-line remote diagnosis monitoring system for DC BUS electrolytic capacitors of power converter using low-cost type Zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using AC coupling method of DC link ripple voltage/current. The Zigbee communication-based experimental results show that the proposed remote DC capacitor diagnosis monitoring system can be applied to DC/DC converter and UPS successfully.

도시철도용 몰드변압기 상태감시를 위한 사례조사 연구 (A case study of condition monitoring for mold transformers on urban railway transit)

  • 김도윤;정호성;박영;한석윤;이상빈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.235-240
    • /
    • 2008
  • Since urban railway transit is one of the most essential transportation systems, its power facilities must ensure high reliability and safety. Currently, urban railway operating organizations perform TBM (Time Based Maintenance) on power facilities. However, in order to improve management efficiency and system safety, CBM (Condition Based Maintenance) is preferred. Among various power facilities, mold transformers has been chosen as the object of study since it is widely used for the purpose of minimizing volume and weight, and due to safety against fire. In this paper, various transformer failure cases due to electric, thermal, mechanical and environmental factors have been collected and analyzed. In addition, investigation on national and international condition based maintenance cases and the characteristics of sensors widely used for transformer monitoring has been performed to suggest the optimal condition based maintenance technique for urban railway systems.

  • PDF