• Title/Summary/Keyword: Power Monitoring Systems

Search Result 765, Processing Time 0.036 seconds

Condition Monitoring of Reliability-Critical Components in Power Electronic Systems (전력전자 시스템에서 신뢰성 취약 소자의 상태 모니터링 방법)

  • Choi, Ui-Min;Lee, June-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.4
    • /
    • pp.244-258
    • /
    • 2019
  • The reliability of power electronic systems becomes increasingly important, as power electronic systems have gradually gained an essential status in a wide range of industrial applications. Accordingly, recent research has made an effort to improve the reliability of power electronic systems to comply with stringent constraints on safety, cost, and availability. The condition monitoring of power electronic components is one of the main topics in the research area of the reliability of power electronic systems. In this paper, condition-monitoring methods of reliability-critical components in power electronic systems are discussed to provide the current state of knowledge by organizing and evaluating current representative literature.

Wide-area Frequency-based Tripped Generator Locating Method for Interconnected Power Systems

  • Kook, Kyung-Soo;Liu, Yilu
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.6
    • /
    • pp.776-785
    • /
    • 2011
  • Since the Internet-based real-time Global Positioning System(GPS) synchronized widearea power system frequency monitoring network (FNET) was proposed in 2001, it has been monitoring the power system frequency in interconnected United States power systems and numerous interesting behaviors have been observed, including frequency excursion propagation. We address the consistency of a frequency excursion detection order of frequency disturbance recorders in FNET in relation to the same generation trip, as well as the ability to recreate by power systems dynamic simulation. We also propose a new method, as an application of FNET measurement, to locate a tripped generator using power systems dynamic simulation and wide-area frequency measurement. The simulation database of all the possible trips of generators in the interconnected power systems is created using the off-line power systems dynamic simulation. When FNET detects a sudden drop in the monitoring frequency, which is most likely due to a generation trip in power systems, the proposed algorithm locates a tripped generator by finding the best matching case of the measured frequency excursion in the simulation database in terms of the frequency drop detection order and the time of monitoring points.

Power Quality Monitoring System with a New Distributed Monitoring Structure

  • Won, Dong-Jun;Chung, Il-Yop;Kim, Joong-Moon;Ahn, Seon-Ju;Moon, Seung-Il;Seo, Jang-Cheol;Choe, Jong-Woong
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.214-220
    • /
    • 2004
  • Power quality monitoring is the cornerstone for power quality analysis, diagnosis and improvement. The measurement of power quality (PQ) evolves from instantaneous metering to continuous monitoring. Furthermore, recent technologies enable us to construct more flexible, reliable, rapid and economical power quality monitoring system (PQMS). Therefore, this paper presents an improved PQMS with a new distributed monitoring structure. The proposed PQMS consists of a PQ meter, PQ analyzer and GUI. The PQ meter only collects raw data and the PQ analyzer performs power quality analysis. It has several advantages compared to conventional structures in economic efficiency, modularity, speed, etc. PQ monitoring algorithms to catch steady-state trends and to detect PQ events are also adapted to the proposed structure. Using the proposed structure and monitoring algorithm, a prototype PQMS is constructed and real-time testing is performed.

A Development of Smart Monitoring Technique for Photovoltaic Power Systems (태양광 발전 시스템의 스마트 모니터링 기술개발)

  • Cho, Hyun Cheol;Sim, Kwang Yeal
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.2
    • /
    • pp.50-56
    • /
    • 2015
  • This paper presents a smart monitoring technique for photovoltaic power systems by using wire and wireless communication networks in which the RS-232/484 and the Zigbee communication networks are inherently established respectively. In the proposed monitoring systems, environmental data sequences and the output power measured by sensors in photovoltaic systems are transferred to PC systems via two communication networks. We made electronic hardware boards for sensors and communication networks to construct its real-time monitoring system and carry out experiments for demonstrating reliability of the proposed monitoring system.

A Development of Real-time Monitoring Techniques for Synchronous Electric Generator Systems (동기 발전기 시스템의 실시간 모니터링 기술 개발)

  • Cho, Hyun Cheol
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.182-187
    • /
    • 2017
  • Synchronous generators have been significantly applied in large-scale power plants and its monitoring systems are additionally established to sequentially observe states and outputs. We develop a computer based monitoring device for three-phase synchronous power generators in this paper. First, a test-bed of such generator system is created and then a interface board is constructed to transfer electric signals including the output voltage and the current from generators into a computer system via a data acquisition device. Its RMS(root-mean-square) values are continuously shown on a screen of computer systems and its time-histories graphs are additionally illustrated under a graphic user interface(GUI) mode. Lastly, we carry out real-time experiments using the generator system with the monitoring device to demonstrate its reliability and superiority by comparing results of a generic power analyzer which is well-used in measuring various power systems practically.

Development of Monitoring and Control System of Utility-Pipe Conduit (Power Tunnel) using PLC

  • Lee, Tae-Young;Park, Byung-Seok;Ju, Seong-Ho;You, Dong-Hee;Lim, Yong-Hoon;Song, Seok-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.116-119
    • /
    • 2004
  • The existing monitoring and control systems of utility-pipe conduit (power tunnel, cable tunnel etc) have established communication lines using optical fiber, leaky coaxial cable (LCX), and several kinds of control cable. Due to the properties of the used media, the cost of equipment is considerably high and the maintenance of the system is difficult. Also, the term of carrying out is long so that the extension of the system is in difficulty. Now it is desirable to adopt Power Line Communication (hereinafter, PLC) technology in the monitoring and control systems and use the existing low-voltage power-line for lamplight as communication line. This will lead the reduction of the construction cost and the easy maintenance of the system. In this paper, we research the characteristics of PLC in conduit, design and manufacture the field test system, and analyze the performance of the system by field test. Then, we introduce the reliable monitoring and control system of utility-pipe conduit using PLC.

  • PDF

A Study on the Power System Control and Monitoring Technique Using CAN (CAN을 이용한 발전계통의 제어 및 모니터링 기법 연구)

  • Jung, Joon-Hong;Choi, Soo-Young;Park, Ki-Heon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.5
    • /
    • pp.268-276
    • /
    • 2003
  • In this paper, we present a new control and monitoring technique for a power system using CAN(Controller Area Network). Feedback control systems having co'ntrol loops closed through a network(i.e. Ethernet, ControlNet, CAN) are called NCSs(Networked Control Systems). The major problem of NCSs is the variation of stability property according to time delay including network-induced delay and computation delay in nodes. We present a new stability analysis method of NCSs with time delay exploiting a state-space model of LTI(Linear Time Invariant) interconnected systems. The proposed method can determine a proper sampling period of NCSs that preserves stability performance even in NCSs with a dynamic controller. We design CAN nodes which can transmit control and monitoring data through CAN bus and apply these to NCSs for a power system. The results of the experiment validate effectiveness of our control and monitoring technique for a power system.

A Study on the Information Exchange Technique among Electric Power Facilities and Monitoring Systems (전력 설비 감시 시스템들 간의 정보 교환 기법에 관한 연구)

  • Hong, Chang-Ho;Park, Chan-Eom;Lee, Seung-Chul;Hoon, Un-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.453-456
    • /
    • 2006
  • In this paper, we introduce the design and implementation of Information exchange technique among power system facilities and/or their monitoring systems based on Universal Description, Discovery and Integration Service and Simple Object Access Protocol. The rapid progresses in high speed network, 4G web language S/W and embedded H/W enabled faster and easier communications among electric power systems monitoring facilities. However, each facility or system has its own specific protocol like RS-232 and RS-486, which somewhat limits the capability of flexible information exchange among thor In this paper, we try to demonstrate the potential of utilizing the SOAP and UDDI services in exchanging the metadata and possibly high abstraction level informations among electric power facilities and/or their monitoring systems.

  • PDF

Monitoring for Mutual Effects of Switching Power Capacitors in Power Systems

  • Ghania, Samy M.;Elwer, Ayman S.;Morsi, Reda;Salama, M.M.A.
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.325-331
    • /
    • 2008
  • Power system perturbations are due to many reasons; one of the most common perturbation causes is switching off/on the power capacitors. This paper monitors and discusses the overvoltages which appear on local and remote capacitor connected buses in power systems. Using the Fast Fourier Transfer (FFT), the total harmonic content of voltages and currents waveforms is also estimated at all buses. The power factor during different cases of switching modes "off/on" is monitored. The monitoring technique tackles not only the longitudinal long distance mutual effects of switching power capacitors between different buses but also evaluates the overvoltage durations. A relative long term monitoring is implemented using the Matlab/Simulink environment to show severity assessments in different switching modes on the transformers' voltages and currents' waveforms.

Development of High Reliability Monitoring and Control System for Platform Screen Door (승강장 스크린 도어(PSD)에 대한 고 신뢰성의 감시 및 제어 시스템 개발)

  • Kim, Jin-Sik;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.158-162
    • /
    • 2010
  • PSD is automatically opened and closed when subway train arrive on the station. This system was designed to control electric automatic system. These doors will provide passenger safety, energy saving and a good environment in subway. The monitoring and control systems of PSD are configured so that they can be operated in automatic mode in connection with ATO through the composite control panel in the station control room. The objective of this paper is to obtain high reliability that is essential for monitoring and control systems of PSD. The power supply is based on protection circuit using DC power bridge from two UPS. Also, stable communication system consists of CAN communication line redundancy and RF cross protection algorithm. Monitoring state display results show the validity of the proposed high reliability monitoring and control systems of PSD.