• Title/Summary/Keyword: Power Method

Search Result 22,276, Processing Time 0.042 seconds

A Study of CPLD Low Power Algorithm using Reduce Glitch Power Consumption (글리치 전력소모 감소를 이용한 CPLD 저전력 알고리즘 연구)

  • Hur, Hwa Ra
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.3
    • /
    • pp.69-75
    • /
    • 2009
  • In this paper, we proposed CPLD low power algorithm using reduce glitch power consumption. Proposed algorithm generated a feasible cluster by circuit partition considering the CLB condition within CPLD. Glitch removal process using delay buffer insertion method for feasible cluster. Also, glitch removal process using same method between feasible clusters. The proposed method is examined by using benchmarks in SIS, it compared power consumption to a CLB-based CPLD low power technology mapping algorithm for trade-off and a low power circuit design using selective glitch removal method. The experiments results show reduction in the power consumption by 15% comparing with that of and 6% comparing with that of.

Analysis of a Communication Network for Control Systems in Nuclear Power Plants and a Case Study (원자력 발전소 제어 계통을 위한 통신망의 해석과 사례 연구)

  • Lee, S.W.;Yoon, M.H.;Moon, H.J.;Shin, C.H.;Lee, B.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.1013-1016
    • /
    • 1999
  • In this paper, a real-time communication method using a PICNET-NP(Plant Instrumentation and Control Network for Nuclear Power plant) is proposed with an analysis of the control network requirements of DCS (Distributed Control System) in nuclear power plants. The method satisfies deadline in case of worst data traffics by considering aperiodic and periodic real-time data and others. In addition, the method was used to analyze the data characteristics of the DCS in existing nuclear power plant. The result shows that use of this method meets the response time requirement(100ms)

  • PDF

A study on the development for the method without interruption of service in the distribution system (배전선로의 무정전공법 개발 연구)

  • Kim, Young-Lae;Park, Ku-Bum;Song, Il-Geun
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.61-63
    • /
    • 1995
  • The main factors to bring out the power failure are trouble and operation power failure, the operation power failure of these includes about 85%. So, it is required that the without interruption of service method reduce the operation power failure. If we develop the without interruption of service method, the operation power failure will reduce greatly. It is necessary to develop the without interruption of service method which it solve various trobles (dissatisfacting solution of customer, sales revenue augmentation, and the reduction of the power failure negotiation work). The results of study are drawing up of the specification for temporary transmission methods, it of the working methods for them, and the scrutiny of the technology contents for them.

  • PDF

A study on comparative analysis of direct current control in A.C.-D.C. interconnected power system (교류-직류 연계계통에 있어서 직류제어방식의 비교연구)

  • 정형환;왕용필;안병철;이광우
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.474-483
    • /
    • 1996
  • In this paper, as a part of the method improving stability, the load-flow calculation in D.C. power system and the models for stability analysis are studied with A.C-D.C. interconnected power systems transmission performed. Moreover, the theory is established in relation to each control method of D.C. power systems. Then the stability of A.C-D.C.interconnected power systems is compared and considered by the way of dividing the operating control method of the rectifier inverter converter into ACR-AVR, APR-A.gamma.R, A.alpha.R-ACR. The dynamics characteristic of terminal voltage, frequency, active-reactive power and rotor angle of the generator with disturbances and load fluctuations is considered. In addition, the characteristic of direct voltage, direct current, power and control systems. From this the comparative analysis of the direct current control method, the possibility of the stability analysis of A.C.-D.C. interconnected power system is considered. (author). refs., figs., tabs.

  • PDF

Key Application Technologies of High Efficiency Power Quality Control Systems

  • Liu, Ding-Guo;Shuai, Zhi-Kang;Tu, Chun-Ming;Cheng, Ying;Luo, An
    • Journal of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.458-468
    • /
    • 2013
  • Large capacity reactive power compensation and harmonic control in the low-voltage grid of an enterprise, are important technical means to improve power quality and reduce power loss. In this paper, the principle of an efficient power quality controller is analyzed. Then, key application technologies of the HPQC which would influence the performances of the HPQC are studied. Based on an analysis of the harmonic shunt problem, a frequency dividing control strategy of the HPQC continuous subsystem is proposed. A parameter design method of the HPQC discrete subsystem and its installation method are also proposed to ensure the system compensation effect. HPQC systems have been designed for a copper foil plant. The effectiveness of this paper has been verified by the simulation and application results.

A Study on Coherency Aggregation Method Using Relation Index of State Variables in the Power System (상태변수들의 관계지수를 이용한 전력시스템 동적 축약기법 연구)

  • Lee, Byung-Ha;Baek, Jung-Myoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1367-1372
    • /
    • 2007
  • The modem large electric power system has made power system analysis much more complex and difficult. For effective analysis of the power system, model reduction and aggregation is required. In this paper, a new relation index to identify the coherency among the generators is presented and also a new aggregation method is presented to aggregate the coherent generators in the large scale power system while matching the power flow. In order to demonstrate the effects of this aggregation method, it is applied to the IEEE 39 bus test power system and to the 2006 summer power system of Korea Electric Power Corporation, and the simulation results are compared with those of the original system.

Analysis of Nigeria Research Reactor-1 Thermal Power Calibration Methods

  • Agbo, Sunday Arome;Ahmed, Yusuf Aminu;Ewa, Ita Okon Bassey;Jibrin, Yahaya
    • Nuclear Engineering and Technology
    • /
    • v.48 no.3
    • /
    • pp.673-683
    • /
    • 2016
  • This paper analyzes the accuracy of the methods used in calibrating the thermal power of Nigeria Research Reactor-1 (NIRR-1), a low-power miniature neutron source reactor located at the Centre for Energy Research and Training, Ahmadu Bello University, Zaria, Nigeria. The calibration was performed at three different power levels: low power (3.6 kW), half power (15 kW), and full power (30 kW). Two methods were used in the calibration, namely, slope and heat balance methods. The thermal power obtained by the heat balance method at low power, half power, and full power was $3.7{\pm}0.2kW$, $15.2{\pm}1.2kW$, and $30.7{\pm}2.5kW$, respectively. The thermal power obtained by the slope method at half power and full power was $15.8{\pm}0.7kW$ and $30.2{\pm}1.5kW$, respectively. It was observed that the slope method is more accurate with deviations of 4% and 5% for calibrations at half and full power, respectively, although the linear fit (slope method) on average temperature-rising rates during the thermal power calibration procedure at low power (3.6 kW) is not fitting. As such, the slope method of power calibration is not suitable at lower power for NIRR-1.

Research on Assessment Method of Deterioration Condition for Power Transformer Using Sweep Frequency Response Analyzer (주파수응답분석기를 이용한 전력용 변압기 열화상태 평가방법 연구)

  • Gil, Hyoung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.8
    • /
    • pp.30-35
    • /
    • 2013
  • This paper describes the assessment method of deterioration condition for a power transformer using SFRA. Frequency Response Analysis(FRA) is a method to evaluate the mechanical and geometrical integrity of the core and windings within a power transformer by measuring the electrical transfer functions over a wide frequency range. SFRA is sweep frequency response analyzer for power transformer winding diagnosis. The FRA is a comparative method, that evaluates the transformer condition by comparing the obtained set of FRA results to reference results on the same, or a similar, unit. FRA techniques were widely used and much more sensitive than the traditional and internationally accepted method of impedance measurements, but that work was required on standardization and interpretation. In order to analyze the deterioration condition for power transformer, overvoltage test and mechanical distortion test were carried out. The deterioration condition for power transformer was evaluated by SFRA. It is intended to present the elemental technology of assessment method for power transformer using SFRA.

A Novel Non-contact Measurement Method for the Detection of Current Flowing Through Concealed Conductors

  • Yang, Fan;Liu, Kai;Zhu, Liwei;Hu, Jiayuan;Wang, Xiaoyu;Shen, Xiaoming;Luo, Hanwu;Ammad, Jadoon
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • In order to detect the current flowing through concealed conductor, this paper proposes a new method based on derivative method. Firstly, this paper analyzes the main peak characteristic of the derivative function of magnetic field generated by a current-carrying conductor, and a relationship between the current flowing through the conductor and the main peak of the derivative function is obtained and applied to calculate the current. Then, the method is applied to detect the conductor current flowing through grounding grids of substations. Finally, the numerical experimental and field experiment verified the feasibility and accuracy of the method, and the computing results show that the method can effectively measure the conductor current of grounding grids with low error, and the error is within 5 %.

Prediction of Wind Power by Chaos and BP Artificial Neural Networks Approach Based on Genetic Algorithm

  • Huang, Dai-Zheng;Gong, Ren-Xi;Gong, Shu
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.41-46
    • /
    • 2015
  • It is very important to make accurate forecast of wind power because of its indispensable requirement for power system stable operation. The research is to predict wind power by chaos and BP artificial neural networks (CBPANNs) method based on genetic algorithm, and to evaluate feasibility of the method of predicting wind power. A description of the method is performed. Firstly, a calculation of the largest Lyapunov exponent of the time series of wind power and a judgment of whether wind power has chaotic behavior are made. Secondly, phase space of the time series is reconstructed. Finally, the prediction model is constructed based on the best embedding dimension and best delay time to approximate the uncertain function by which the wind power is forecasted. And then an optimization of the weights and thresholds of the model is conducted by genetic algorithm (GA). And a simulation of the method and an evaluation of its effectiveness are performed. The results show that the proposed method has more accuracy than that of BP artificial neural networks (BP-ANNs).