• Title/Summary/Keyword: Power Line Conductor

검색결과 146건 처리시간 0.031초

14 GHz 헤어핀형 초전도 대역통과 필터 (Superconducting Bandpass Fitter Using Hairpin-type Microstrip Line with Narrow Bandwidth Centered at 14 GHz)

  • 송석천;김철수;이상렬;윤형국;윤영중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1852-1854
    • /
    • 1999
  • In order to enhance satellite communication system performance, filters are required with the characteristics of sharp skirt, low insertion loss, and high power handling capability. But the performance of microwave passive filters is significantly declined by the conduction losses, especially in case of planar structures using film conductors. By using high temperature superconducting(HTS) film material as the conductor, higher performance could be expected. We have designed and developed narrow bandpass filters using haripin-type superconducting microstrip line for satellite communication. High quality superconducting YBCO thin films have been grown on MgO substrates by pulsed laser deposition(PLD) The deposited YBCO films were patterned by conventional wet-etching process. The transition temperatures of these films had shown 86 - 89 K. The film thicknesses were about 500 nm. Experimental results are presented for the insertion loss and return loss of the filter at 60 K.

  • PDF

Uncertainty Analysis of Dynamic Thermal Rating of Overhead Transmission Line

  • Zhou, Xing;Wang, Yanling;Zhou, Xiaofeng;Tao, Weihua;Niu, Zhiqiang;Qu, Ailing
    • Journal of Information Processing Systems
    • /
    • 제15권2호
    • /
    • pp.331-343
    • /
    • 2019
  • Dynamic thermal rating of the overhead transmission lines is affected by many uncertain factors. The ambient temperature, wind speed and wind direction are the main sources of uncertainty. Measurement uncertainty is an important parameter to evaluate the reliability of measurement results. This paper presents the uncertainty analysis based on Monte Carlo. On the basis of establishing the mathematical model and setting the probability density function of the input parameter value, the probability density function of the output value is determined by probability distribution random sampling. Through the calculation and analysis of the transient thermal balance equation and the steady- state thermal balance equation, the steady-state current carrying capacity, the transient current carrying capacity, the standard uncertainty and the probability distribution of the minimum and maximum values of the conductor under 95% confidence interval are obtained. The simulation results indicate that Monte Carlo method can decrease the computational complexity, speed up the calculation, and increase the validity and reliability of the uncertainty evaluation.

지중배전선로 무정전 공법의 최적화를 위한 장비 개발 (Development of outage-free installation method and equipments for underground power distribution system)

  • 유근양;주종민;이용순;김영민;강내국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.122-124
    • /
    • 2005
  • Underground distribution system is a trend due to the successive development of metropolitan area and satellite cities and the environment of the commercial and residential areas. The high quality of electricity, which is related with the minimal outage duration time due to the maintenance work for the underground distribution line, is mandatory. Hence, the construction method and tools for the outage-free maintenance construction have been required for underground distribution system. So far, all the efforts for outage-free maintenance for the underground distribution have been limited only to the survey for foreign countries situation and the theoretical provision; thus, It is required to develop the various construction method and the application tools. Differently from the aerial line, the construction of the underground cable is complicated and the insulation distance between conductor and shield should be maintained in loadmaking/breaking operation, though the apparatus connected with cable is a deadfront type. Also since the apparatus is installed above ground, by-pass of faulted area at busy area needs a variety of high technologies. Therefore, in this these, the authors introduce the development status of the loadbreak connectors, connection facilities, outage-free maintenance system for secondary side, a secondary auxiliary bushing and additional tools so that there can be more progress on this field.

  • PDF

UHF Sensor를 이용한 SF6 절연 MV 개폐기의 부분방전 검출 시스템 (Partial Discharge Monitoring for $SF_6$ Insulated MV Switchgear using UHF sensors)

  • 이도훈;강원종;신양섭;김영근;오일성;김동명;권태호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.2040-2041
    • /
    • 2007
  • In this paper, the UHF PD(Partial Discharge) sensors for $SF_6$ insulated MV $SF_6$ switchgear have been proposed and related investigations have been performed in order to detect the PD which were produced inside the MV $SF_6$ switchgear. Firstly, the internal type UHF PD sensor based on spiral antenna theory has been developed. This type sensor is highly sensitive and has lowly effect on by on-site noise. Secondly, the external type UHF PD sensor was developed based on log periodic antenna concept. This type sensor is removable and detectable for operating switchgear. These sensors were designed and simulated using RF simulation tool. In order to verify the sensitivity of these sensors, we performed the on-site test using the mock-up switchgears including the artificial defects which were the protrusion on high voltage conductor, free moving metal particle and surface defect on insulator. These mock-up switchgear were installed on the test distribution line.

  • PDF

마이크로 솔레노이드의 해석 및 설계 (Analysis and Design of Micro Solenoid)

  • 전용식;배상규;김동수
    • 유공압시스템학회논문집
    • /
    • 제3권4호
    • /
    • pp.14-20
    • /
    • 2006
  • Recently, the on-off solenoid valves have been focused on core technology in the fields of the production line of semi-conductor chips and the micro fluid chips for bio-medical applications. A key characteristics for on-off solenoid valve, operated by compressed air, are high speed response and great repeatability. Indeed, it is also important to keep the pressure on the cross-sectional area of the poppet to be constant regardless of the fluctuation of the pressure exerted on the ports. In this study, we have designed and analysed the high-speed and high flow rate on-off solenoid valve using the analogy of equivalent magnetic circuit and Finite Element Method (FEM) respectively. In case of poppet, flow field characteristics was analyzed by the variation of poppet and it was able to display flow field by changing the location of the poppet. Also, we verified possibility of the design through the static and dynamic pressure and the 3D simulation using distribution curve of the force by working the front poppet.

  • PDF

22.9[kV] 지중배전계통케이블의 동심중성선에 흐르는 순환전류의 제거방안 및 효과 (An Elimination Method Of the Circulating Current Flowing into Coaxial-Neutral Lines in 22.9[kV] CNCV Underground Cable Systems)

  • 전명수;송중호
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.107-113
    • /
    • 2008
  • 22.9[kV]-y 배전 방식은 지중 케이블로 전력을 공급하고 있으며 선로 운영상 배전케이블 선로의 동심중성선을 케이블 접속 구간마다 3선 일괄 접지하는 다중 접지방식을 채택하고 있다. 그러나 지중 배전 선로에서 각 상의 부하가 평형일 경우에도 동심중성선에는 부하 전류의 약 40[%](전력구)${\sim}$50[%](관로)의 동심중성선 순환 전류가 발생되고 있기 때문에, 순환전류로 인한 손실이 도체 손실의 76[%]에 달한다. 이러한 손실 전력으로 케이블의 내부온도가 상승되어 케이블의 허용전류 용량이 관로의 경우 20[%] 정도 감소하게 된다. 본 논문은 이와 같은 문제점을 해결하기 위하여 새로운 동심중성선 접지방식을 제안하고 있다. 새로운 방법은 동심중성선의 순환전류를 효과적으로 제거하고 있으며, 그 방안을 직접 계통망에서 적용시켜서 실측하여 본 결과, 그 타당성과 유용성을 확인하였다.

Effect of Impurities on Stress Induced Void Formation in Al-1% Si Conductors

  • Lee, Seong-Min
    • Transactions on Electrical and Electronic Materials
    • /
    • 제2권3호
    • /
    • pp.12-17
    • /
    • 2001
  • It is shown in the present study that during the HTS (hot temperature storage) test, the metal contamination by impure elements can be highly susceptible to the void formation, leading to the open failure of the power line in the memory device. Such a functional failure associated with the metal contamination was investigated to be dominant in the early stages of the HTS test while the formation of a stress-driven void is mainly observed in the later stages. In particular, it was found that the void formed in the contaminated metal takes on a slit-like shape which has been known to be characteristic of the stress-related voiding. The impure elements leading to the metal degradation were identified to be carbon and oxygen introduced during the metal sputtering process. The experimental works show that the device reliability was significantly improved by reducing the level of such impure elements within metal. It is shown in the present study that during the HTS (hot temperature storage) test, the metal contamination by impure elements can be highly susceptible to the void formation, leading to the open failure of the power line in the memory device. Such a functional failure associated with the metal contamination was investigated to be dominant in the early stages of the HTS test while the formation of a stress-driven void is mainly observed in the later stages. In particular, it was found that the void formed in the contaminated metal takes on a slit-like shape which has been known to be characteristic of the stress-related voiding. The impure elements leading to the metal degradation were identified to be carbon and oxygen introduced during the metal sputtering process. The experimental works show that the device reliability was significantly improved by reducing the level of such impure elements within metal.

  • PDF

2회선 가공송전선의 단시간정격에 관한 평가방법 (An Evaluation Method for Short-Term Ratings of Double-Circuit Overhead Transmission Lines)

  • 김성덕;손홍관;장태인
    • 조명전기설비학회논문지
    • /
    • 제21권7호
    • /
    • pp.20-28
    • /
    • 2007
  • 본 논문에서는 2회선 가공송전선에 대하여 2회선 중 1회선에 고장이 발생한 경우에 안전하게 운전할 수 있는 단시간정격을 결정하기 위한 해석적 방법을 기술한다. 도체의 온도특성을 나타내는 열평형방정식을 선형화 함으로써 이 선형방정식으로 1회선 선로에 과부하가 발생하는 동안 과전류와 그 온도 특성을 쉽게 표현할 수 있다. 일반적으로 단시간 선로정격은 도체의 수명과 이도를 동시에 고려하여 결정해야 한다는 것은 잘 알려진 사실이다. 그렇지만 대부분의 전력회사는 단시간정격에 대한 각자의 다른 지침을 갖고 있다. 이 논문에서는 제안된 방법을 사용하면 과거 3시기에 건설된 한국전력공사의 가공송전선에 규정된 단시간정격을 재평가할 수 있고, 그 결과 단시간정격을 효율적으로 증대시킬 수 있음을 확인하였다. 또한 이 방법은 2회선 선로 중 1회선에 고장이 발생할 경우에 기존 선로에 어떤 조치도 하지 않아도 단시간 동적송전용량을 결정하는데 직접 이용할 수 있을 것이다.

저진공 펌프의 운전 특성 (Operating Characteristics of Low Vacuum Pumps)

  • 임종연;심우건;정광화
    • 한국진공학회지
    • /
    • 제12권2호
    • /
    • pp.93-104
    • /
    • 2003
  • 저진공펌프의 내구성평가와 관련하여 펌프의 성능이나 상태의 저하에 관한 기술적 근거를 확보함으로써 펌프의 운전상태를 진단할 수 있는 기초기술을 확보할 수 있으며, 이는 진공펌프의 기계적 결함 및 성능평가 장치의 동적 응답과 신뢰도 구축에 중점을 두고 신호 분석을 통하여 실험적으로 기계적인 동적 특성을 확인하는 과정을 통하여 수행할 수 있다. 저진공펌프의 압축일에 소요되는 전력을 이론적으로 규명하고 펌프의 압축일을 계산하였으며, 소비전력에 대한 진공펌프의 에너지 효율을 예측하여 펌프 노화에 따르는 소비전력의 증가 원인을 규명하는 자료로 활용할 수 있다. 또한 저진공펌프의 가동 중에 측정한 진동, 압력신호, 배기속도 및 소비전력을 측정하고 분석하여 펌프 운전상태를 감시하는데 매우 유용한 인자가 무엇인지 확인하였으며 추후 연구의 방향과 내구성평가의 기초기술을 확보하였다.

결합 전송선로 이론을 이용한 적층 세라믹 커패시터의 임피던스 특성 예측 (Prediction of Impedance Characteristics of Multi-Layer Ceramic Capacitor Based on Coupled Transmission Line Theory)

  • 전지운;김종현;푸 보;장 난;송승제;나완수
    • 한국전자파학회논문지
    • /
    • 제26권2호
    • /
    • pp.135-147
    • /
    • 2015
  • 전자 산업에서의 소형화와 디지털화에 따라 적층 세라믹 커패시터(Multi-Layer Ceramic Capacitors: MLCC) 또한 DC Blocking, 디커플링, 필터링 등의 기능이 이에 부응하여 그 수요가 꾸준히 증가해왔다. 이에 따라 MLCC의 등가회로를 모델링하는 기법이 많이 연구되었는데, 지금까지의 연구를 살펴보면 대부분이 소자의 주파수 특성을 측정한 후, 그 결과를 바탕으로 소자를 모델링하므로 제작 과정과 측정 과정에서 물질적, 시간적 손실을 수반한다. 이를 해결하기 위한 방법으로 본 논문에서는 구조 정보와 물질 정보로부터 설계단계에서 MLCC의 임피던스 특성을 예측할 수 있는 모델링 방법을 제시한다. 미분 방정식으로 표현되는 결합 전송선로 방정식으로부터 임의의 N개 층을 가지는 다층 평판 커패시터(N-Layer Capacitor)의 임피던스를 구조 정보와 물질 정보의 수식으로 표현할 수 있음을 보였다. 이렇게 정의된 임피던스 수식으로부터 임의의 구조 정보와 물질 정보를 가지는 MLCC의 임피던스를 예측하였으며, EM 시뮬레이션 결과와 비교하였다. 그 결과, 제시한 임피던스 예측 모델링 결과와 측정 결과가 잘 일치하였고, EM 시뮬레이션보다 훨씬 빠르게 예측 결과를 얻을 수 있음을 보였다.