• 제목/요약/키워드: Power Level

검색결과 7,374건 처리시간 0.031초

굴착기의 음향파워레벨 회귀분석 (Regression Analysis of an Excavator Sound Power Level)

  • 구진회;이재원;서충열;장성기;최경희;한진석
    • 한국소음진동공학회논문집
    • /
    • 제22권3호
    • /
    • pp.203-207
    • /
    • 2012
  • The noise emitted from an excavator has long been a cause of environmental disputes, while causing displeasure to the nearby residents. So, the ministry of environment adopted the construction machinery noise labeling system to encourage the construction machinery manufacturing companies to develop the low noise construction machinery voluntarily. But, as the quality of life improves, a growing number of people desire the comfortable and quite environment to live in. Under the situation, noise from the construction machinery has been a major cause for stress and complaints. When the noise dispute happened in the construction site, the sound pressure level of the construction machinery like a excavator was measured at the lot boundary of the noise victim's residence to judge how much noise damage occur. But the sound pressure level of the construction machinery is measured differently according to the acoustic environment of construction site and the measuring position, respectively, which makes it difficulty to judge whether the noise damage occur or not. As the sound power level of noise source is not affected by the acoustic environment of construction site and the measuring position, if we use the information of the sound power level, it will be easy to judge whether the noise damage occur and to establish the soundproofing measures. Therefore, we derive the sound power level regression model of the excavator to judge whether the noise emitted from the excavator damages to residents near the construction site. Also, the sound power level regression model of the excavator drawn in this paper will help construction companies to plan the noise reduction program in the construction sites.

간호사 노동시장의 수요독점에 대한 연구 - 종합병원을 중심으로 - (Monopsony Power of General Hospitals in Nurse Labor Market)

  • 정현진;양봉민
    • 한국병원경영학회지
    • /
    • 제5권2호
    • /
    • pp.40-58
    • /
    • 2000
  • Nurses are medical personnel, who play a key role in supporting patient care, so it is important to supply them adequately in balance with ever increasing medical demand. But there appears severe shortage of nurses in some hospitals because of their uneven distribution, especially in small sized-hospitals and rural-hospitals. As nationwide distorted distribution of nurses in Korea is just like what monopsony model(a kind of market structure model) tells us, it is attempted to explain this situation of nurse labor market in Korea on the basis of monopsony model and presented in this paper. Specifically, determinants of nurse wage and the level of their relative employment were examined, and monopsony impact on their wage and the level of relative employment controlling those determinants were studied. Major results of this study arc as follows. The most important determinant of nurse wage level in this study was the wage level of a local community where each hospital located Hospital owner's characteristics an educational function of each hospital were also important factors. With these factor controlled, it was found that monopsony power of each hospital was negativel associated with nurse wage level as expected. 1% increase in monopsony power of hospital(measured by Herfindah-Hirschman Index) reduced nurse wage by $5,674{\sim}19,19$ won(in Korean currency). With regard to the level of relative employment, the most important determinant wa the capacity for supplying nurses of the local community. Again, hospital owner characteristics and educational function of each hospital were also important. With these factors controlled, it was found that monopsony power of each hospital was negative associated with the number of nurses per bed, as expected. 1% increase in monopsony power of each hospital(again measured by Herfindah-Hirschman Index) reduced the number of nurses per 100 bed as much as $0.46{\sim}0.67$. In conclusion. structural factors of nurse labor market influence the instability of nurse labor supply in Korea. Further consideration for these market structural characteristics needed for policy making related to nurse resource allocation.

  • PDF

Performance of multi-level QAM transceiver with adaptive power control in fixed wireless channel

  • Lee, Seong-Choon;Lee, Yong-Hwan
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 제13회 신호처리 합동 학술대회 논문집
    • /
    • pp.533-536
    • /
    • 2000
  • We consider the design of quadrature amplitude modulation (QAM) transceivers f3r fixed wireless communications. The use of adaptive power control in the transmitter (Tx) can provide BER performance robust to fading and improved BER performance. The BER performance is evaluated by analytical and simulation results when multi-level QAM transceiver employing power control in the Tx is applied to fixed wireless channel with flat fading and frequency selective fading. The effect of power control parameters such as power control range and power control step size is investigated

  • PDF

Application of Fuzzy PI Control Algorithm as Stator Power Controller of a Double-Fed Induction Machine in Wind Power Generation Systems

  • Chung, Gyo-Bum;Choi, Jae-Ho
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.109-116
    • /
    • 2009
  • This paper addresses the output control of a utility-connected double-fed induction machine (DFIM) for wind power generation systems (WPGS). DFIM has a back-to-back converter to control outputs of DFIM driven by the wind turbine for WPGS. To supply commercially the power of WPGS to the grid without any problems related to power quality, the real and reactive powers (PQ) at the stator side of DFIM are strictly controlled at the required level, which in this paper is realized with the Fuzzy PI controller based on the field orientation control. For the Sinusoidal Pulse Width Modulation (SPWM) converter connected to the rotor side of DFIG to maintain the controllability of PQ at the state side of DFIM, the DC voltage of the DC link capacitor is also controlled at a certain level with the conventional Proportion-Integral (PI) controller of the real power. In addition, the power quality at the grid connected to the rotor side of DFIM through the back-to-back converter is maintained in a certain level with a PI controller of the reactive power. The controllers for the PQ at the stator side of DFIM, the DC link voltage of the back-to-back inverter and the reactive power at the grid connected to the rotor side of DFIM are designed and simulated in the PSIM program, of which the result verifies the performance of the proposed controllers.

DSP-Based Simplified Space-Vector PWM for a Three-Level VSI with Experimental Validation

  • Ramirez, Jose Dario Betanzos;Rivas, Jaime Jose Rodriguez;Peralta-Sanchez, Edgar
    • Journal of Power Electronics
    • /
    • 제12권2호
    • /
    • pp.285-293
    • /
    • 2012
  • Multilevel inverters have gained attention in high-power applications due to their numerous advantages in comparison with conventional two-level inverters. In this paper a simplified Space-Vector Modulation (SVM) algorithm for a three-level Neutral-Point Clamped (NPC) inverter is implemented on a Freescale$^{(R)}$ DSP56F8037. The algorithm is based on a simplification of the space-vector diagram for a three-level inverter so that it can be used with a two-level inverter. Once the simplification has been achieved, calculation of the dwell times and the switching sequences are carried out in the same way as for the two-level SVM method. Details of the hardware design are included. Experimental results are analyzed to validate the performance of the simplified algorithm.

Practical Methodology of the Integrated Design and Power Control Unit for SHEV with Multiple Power Sources

  • Lee, Seongjun;Kim, Jonghoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.353-360
    • /
    • 2016
  • Series hybrid electric vehicles (SHEVs) having multiple power sources such as an engine- generator (EnGen), a battery, and an ultra-capacitor require a power control unit with high power density and reliable control operation. However, manufacturing using separate individual power converters has the disadvantage of low power density and requires a large number of power and signal cable wires. It is also difficult to implement the optimal power distribution and fault management algorithm because of the communication delay between the units. In order to address these concerns, this approach presents a design methodology and a power control algorithm of an integrated power converter for the SHEVs powered by multiple power sources. In this work, the design methodology of the integrated power control unit (IPCU) is firstly elaborately described, and then efficient and reliable power distribution algorithms are proposed. The design works are verified with product-level and vehicle-level performance experiments on a 10-ton SHEV.

EMS data 분석 및 최적화 기법을 적용한 제어지역별 목표운전전압 제안 (Target Operation Voltage Guidelines Considering Voltage Level in Each Voltage Control area by Applying Optimization Technique Through EMS Data Observation)

  • 성웅;김재원;김태균;이병준;정응수;조종만
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.671-678
    • /
    • 2009
  • This paper presents target operation voltage guidelines of each voltage control area considering both voltage stability and economical efficiency in real power system. EMS(Energy Management System) data, Real-time simulator, shows not only voltage level but lots of information about real power system. Also this paper performs optimal power flow calculation of three objective functions to propose the best target operation voltage. objective function of interchange power flow maximum and active power loss minimization stand for economical efficiency index and reactive power reserve maximum objective unction represents stability index. Then through simulation result using optimazation technique, the most effective objective function is chosen. To sum up, this paper divides voltage control area into twelve considering electric distance characteristics and estimate or voltage level by the passage of time of EMS peak data. And through optimization technique target operation voltage of each voltage control area is estimated and compare heir result. Then it is proposed that the best scenario to keep up voltage stability and maximize economical efficiency in real power system.

Dual-model Predictive Direct Power Control for Grid-connected Three-level Converter Systems

  • Hu, Bihua;Kang, Longyun;Feng, Teng;Wang, Shubiao;Cheng, Jiancai;Zhang, Zhi
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1448-1457
    • /
    • 2018
  • Many researchers devote themselves to develop model-predictive direct power control (MPDPC) so as to accelerate the response speed of the grid-connected systems, but they are troubled its large computing amount. On the basis of MPDPC, dual MPDPC (DMPDPC) is presented in this paper. The proposed algorithm divides the conventional MPDPC into two steps. In the first step, the optimal sector is obtained, which contains the optimal switching state in three-level converters. In the second step, the optimal switching state in the selected sector is searched to trace reference active and reactive power and balance neutral point voltage. Simulation and experiment results show that the proposed algorithm not only decreases the computational amount remarkably but also improves the steady-state performance. The dynamic response of the DMPDPC is as fast as that of the MPDPC.

고전압 대용량 유도전동기 구동용 H-브릿지 멀티레벨 인버터의 신뢰성 향상 (Reliability Improvement of H-Bridge Multi-level Inverter for Medium-Voltage & High-Power Induction Motor Drives)

  • 박영민;이광환;이세현
    • 전력전자학회논문지
    • /
    • 제19권2호
    • /
    • pp.99-105
    • /
    • 2014
  • This paper proposes the reliability improvement of H-Bridge Multi-level (HBM) inverter. This reliability can be implemented through modularization of power circuit, distribution of controller, duplication of controller and communication, and continuous operation method in case of power cell failure for driving medium-voltage & high-power induction motor. It is shown that the modularization and expansion characteristics of the HBM inverter are improved since the individual inverter modules operate more independently when using the proposed concept. Also the fault tolerance is increased by using power cell bypass. The proposed design and control methods are described in detail and the validity of the proposed system is verified experimentally in various industrial fields.

옵셋 인쇄기계 동력규모 변화에 따른 소음 영향 평가 (The Noise Influence Assessment according to the Change of the Offset Type Print Machine's Power)

  • 구진회;권명희;이우석;이재원;박형규;김삼수;윤희경;이규목;정대관;서충열
    • 한국소음진동공학회논문집
    • /
    • 제24권9호
    • /
    • pp.682-686
    • /
    • 2014
  • Nowadays, the needs to revise the classification criteria for noise emission facilities have been suggested by the related industries. Because there existed many reasonable factors in the criteria regarding the noise emission facilities. And the noise emission facility classification criterion of the print machine changed from 50 HP to 100 HP in 2013. But the increasement of the noise emission facility classification criterion of the print machine can cause adverse effects like the bigger noise. So, in this paper, we measured the print machine's sound power level according to the changes of the print machine's power to assess the adverse effects. The measurement method applied with KS I ISO 9614-2(1996). The corelation between the sound power level and the power of print machines was analyzed by regression analysis. In this paper, we found that the sound power level of the print machines can increase about 1.3 dB in the condition of that the power of print machine increases from 50 HP to 100 HP. And we found that the sound power level of the print machines can increase about 1.0 dB for a increasement of 1,000 SPH(sheet per hour) of printing speed. The noise emission characteristics of print machine stuied in this paper will be useful to design the noise reduction plan in the future.