• 제목/요약/키워드: Power Injection Method

검색결과 325건 처리시간 0.03초

Consideration of the Carrier Based Signal Injection Method in Three Shunt Sensing Inverters for Sensorless Motor Control

  • Jung, Sungho;Ha, Jung-Ik
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1791-1801
    • /
    • 2016
  • This paper considers a carrier based signal injection method for use in the three shunt sensing inverter (TSSI) for sensorless motor control. It also analyzes the loss according to the injection axis of the voltage signal. To remove both the phase current and rotor position sensors, a sensorless method and a phase current reconstruction method can be simultaneously considered. However, an interaction between the two methods can be incurred when both methods inject voltage signals simultaneously. In this paper, a signal injection based sensorless method with the 120° OFF Discontinuous PWM (DPWM) is implemented in a TSSI to avoid this interaction problem. Since one leg does not have a switching event for one sampling period in the 120° OFF DPWM, the switching loss is altered according to the injection axis. The switching loss in the d-axis injection case can be up to 32% larger than that in the q-axis injection case. Other losses according to the injection axis are also analyzed.

A New Control Scheme for Unified Power Quality Compensator-Q with Minimum Power Injection

  • Lee, Woo-Cheol
    • Journal of Power Electronics
    • /
    • 제7권1호
    • /
    • pp.72-80
    • /
    • 2007
  • Voltage sags are one of the most frequently occurring power quality problems challenging power systems today. The Unified Power Quality Conditioner (UPQC) is one of the major custom power solutions that are capable of mitigating the effect of supply voltage sags at the load or Point of Common Coupling (PCC). A UPQC-Q employs a control method in which the series compensator injects a voltage that leads the supply current by $90^{\circ}C$ so that the series compensator at steady state consumes no active power. However, the UPQC-Q has the disadvantage that its series compensator needs to be overrated. Thus it cannot offer effective compensation. This paper proposes a new control scheme for the UPQC-Q that offers minimum power injection. The proposed minimum power injection method takes into consideration the limits on the rated voltage capacity of the series compensator and its control scheme. The validity of the proposed control scheme is investigated through simulation and experimental results.

Immunity Test for Semiconductor Integrated Circuits Considering Power Transfer Efficiency of the Bulk Current Injection Method

  • Kim, NaHyun;Nah, Wansoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권2호
    • /
    • pp.202-211
    • /
    • 2014
  • The bulk current injection (BCI) and direct power injection (DPI) method have been established as the standards for the electromagnetic susceptibility (EMS) test. Because the BCI test uses a probe to inject magnetically coupled electromagnetic (EM) noise, there is a significant difference between the power supplied by the radio frequency (RF) generator and that transferred to the integrated circuit (IC). Thus, the immunity estimated by the forward power cannot show the susceptibility of the IC itself. This paper derives the real injected power at the failure point of the IC using the power transfer efficiency of the BCI method. We propose and mathematically derive the power transfer efficiency based on equivalent circuit models representing the BCI test setup. The BCI test is performed on I/O buffers with and without decoupling capacitors, and their immunities are evaluated based on the traditional forward power and the real injected power proposed in this work. The real injected power shows the actual noise power level that the IC can tolerate. Using the real injected power as an indicator for the EMS test, we show that the on-chip decoupling capacitor enhances the EM noise immunity.

수분사를 통한 마이크로터빈 성능향상 해석 (Analysis of Performance Enhancement of a Microturbine by Water Injection)

  • 전무성;이종준;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제12권2호
    • /
    • pp.46-51
    • /
    • 2009
  • Recently, microturbines have received attention as a small-scale distributed power generator. Since the exhaust gas carries all of the heat release, generating hot water is usual method of heat recovery from microturbine CHP (combined heat and power) systems. The power of microturbines decreases as ambient temperature increases. This study predicted micoturbine power boost by injecting hot water generated by heat recovery. Influence of injecting water at two different locations was examined. Water injection improves power, but efficiency depends much on the injection location. Injecting water at the compressor discharge shows a much higher efficiency than the combustor injection. However, the combustor injection may have as much available cogeneration heat as the dry operation, while the available heat in the compressor discharge injection is much smaller than the dry operation.

능동형 교류 전력 필터에 의한 고조파 보상전류의 새로운 주입방식 (A New Injection Method of Harmonic Compensation Current by Active AC Power Filter)

  • 박민호;최규하
    • 대한전기학회논문지
    • /
    • 제34권9호
    • /
    • pp.361-367
    • /
    • 1985
  • A new injection method is proposed for active power filters to eliminate AC harmonics in ac input current of nonlinear loads such as rectifiers. By injecting the PWM current determined by the proposed injection method, all the harmonics up to order nn can be eliminated to exactly zero. This PWM injection current can be generated by sampling total harmonic wave at the rate of M and the sampled values are converted into the proposed PWM wave with N pulse-width variables and adjustable current magnitude Im. These variables are deetermined by solving a set of N nonlinear harmonic equations and the harmonic-elimination characteristics of the new injection are investigated through digital computer sinmulation. Also by comparing between the simulated results and the ones synthesized by data stored in EPROM, the possibility of the suggested injection method can be shown.

  • PDF

고조파 제거 및 무효전력 보상을 위한 3상 전력용 능동 필터의 제어에 관한 연구 (A Study on Control Scheme of 3-Phase Active Power Filter for Harmonic Elimination and Reactive Power Compensation)

  • 박민호;최규하;최재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 추계학술대회 논문집 학회본부
    • /
    • pp.291-295
    • /
    • 1989
  • The conventional Optimized Injection Method is a good control technique but can't be applied to 3-phase a.e. line. In this paper, a new technique, Time-sharing Method based on basic principle of conventional Optimized Injection Method is introduced to hold the independence of each phase, and the structure of power circuit is improved to realize the new control method. By this scheme it is possible to simplify the control circuit and power circuit. The characteristic of the new control method are investigated and compared with conventional Optimized Injection Method by computer simulation.

  • PDF

전류 주입형 방식의 UPFC 모델을 이용한 과도 안정도 해석 (Modeling of Unified Power Flow Controllers Using a Current Injection Method for Transient Stability Analysis)

  • 김천회;박정수;장길수;손광명;김태균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.332-334
    • /
    • 2005
  • This paper presents a dynamic simulation of the unified power flow controller (UPFC) using a current injection method. Flexible AC Transmission System (FACTS) devices give more flexibility of control for security and economic operation of power systems. Diffculties of modeling UPFC in the conventional dynamic simulation programs arise from the fact that the injected voltage by the series inverter is superimposed on the shunt inverter side voltage. A solution can be a current injection method, in which a serial part of UPFC is converted to a parallel equivalent circuit using source transformation, and two current sources affect each other at every time step. To verify efficiency of this method, the proposed model is applied for the transient analysis of an example power system.

  • PDF

CIM(Current Injection Method)을 이용한 Charge-Pump 방식의 Plasma Backlight용 고압Inverter (Charge-Pump High Voltage Inverter for Plasma Backlight using Current Injection Method)

  • 장준호;강신호;이경인;이준영
    • 전력전자학회논문지
    • /
    • 제12권5호
    • /
    • pp.386-393
    • /
    • 2007
  • 본 논문에서는 CIM(Current Injection Method)을 이용한 charge-pump방식의 plasma backlight용 고압 inverter회로를 제안한다. 고압 inverter에서 에너지 회수회로의 채용은 새로운 시도로서 에너지회수 이외에도 noise에 의한 시스템의 불안정성과 방전안정화에 기여하고 있다. charge-pump방식으로 스위치류의 내압을 저감하므로 cost면에서 매우 유리한 조건을 확립하였으며 CIM(Current Injection Method)방식의 적용으로 high speed 에너지 회수를 가능하게 하였다. 그리고 제안회로의 동작을 모드별로 해석하였으며, 실제 32" 패널에 적용하여 실험함으로써 제안한 회로의 유용성을 입증하였다.

분사압력변화가 증발자유디젤분무의 혼합기형성과정에 미치는 영향 (Effect of the Change in Injection Pressure on the Mixture Formation Process in Evaporative Free Diesel Spray)

  • 염정국;정성식
    • 동력기계공학회지
    • /
    • 제9권4호
    • /
    • pp.214-219
    • /
    • 2005
  • The effects of change in injection pressure on spray structure in high temperature and pressure field have been investigated. The analysis of liquid and vapor phases of injected fuel is important for emissions control of diesel engines. Therefore, this work examines the evaporating spray structure using a constant volume vessel. The injection pressure is selected as the experimental parameter, is changed from 72MPa to 112MPa by using a common rail injection system(ECD-U2). The images of liquid and vapor phase in the evaporating free diesel spray are simultaneously taken by exciplex fluorescence method. As a result, it can be confirmed that the distribution of vapor concentration is more uniform in the case of the high injection than in that of the low injection pressure.

  • PDF

단상 전류원형 능동전력필터를 위한 펄스폭 변조법의 개선 (An Improvement of PWM Method for Single Phase Current Source Type Active Power Filter)

  • 박인규;박종근
    • 대한전기학회논문지
    • /
    • 제39권3호
    • /
    • pp.254-262
    • /
    • 1990
  • In the active power filter, the PWM method for controlling the power converter plays an important role for the performance and the efficiency of the filter. In this paper, a new PWM method for the single phase current source type active power filter is presented, which is intended particularly for obtaining the maximum efficiency of the compensation. This method is basically based upon the optimized injection method, but in contrast to the existing method, this method adapts the optimized injection method by putting not only the pulse width, but also the pulse position into control variables. By doing this, when the number of pulses per one cycle is N, lower order harmonics up to the Nth order can be completely eliminated by the filter. So, this method is much more efficient than any other existing method. These characteristics are well verified by the computer simulations and the experiments.

  • PDF