• 제목/요약/키워드: Power Imbalance

Search Result 276, Processing Time 0.027 seconds

Bidirectional Dual Active Half-Bridge Converter Integrated High Power Factor Correction

  • Ngo, AnhTuan;Nam, Kwanghee
    • Proceedings of the KIPE Conference
    • /
    • 2011.07a
    • /
    • pp.444-446
    • /
    • 2011
  • A bidirectional dual active converter with the power factor control capability is proposed as a battery charger. The source side half-bridge acts as a PWM converter that maintains the unity power factor. The battery side half-bridge converter acts as a dual active bridge (DAB) together shares the same DC link voltage with PWM converter. The imbalance voltage phenomenon is eliminated by employing asymmetric duty cycle technique. Simulation results are included to verify theoretical analysis.

  • PDF

Fault Current Limiting Characteristics of Flux-lock Type SFCL with Several Secondary Windings

  • Lim, Sung-Hun;Park, Chung-Ryul;Han, Byoung-Sung;Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.5
    • /
    • pp.193-197
    • /
    • 2005
  • We investigated fault current limiting characteristics of the flux-lock type superconducting fault current limiter (SFCL), which consisted of a primary winding and several secondary windings connected in series between $high-T_C$ superconducting (HTSC) thin films. Each YBCO thin film has a 2 mm wide and 42 cm long meander line with 14 stripes of different length. The power imbalance due to the slight difference of Ie between YBCO current limiting elements causes the significant power burden on YBCO element with lower $I_C$. We confirmed from our experiments that the mutual coupling between the primary winding and secondary windings of the flux-lock type SFCL reduced the power imbalance between YBCO current limiting elements compared with the resistive type SFCL connected in series.

Compact and Wideband Correlator with Metamaterial Hybrid Rat-Race Coupler (Metamaterial 하이브리드 Rat-Race Coupler를 이용한 소형화된 광대역 코릴레이터)

  • Kim, Yang-Hyun;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.2
    • /
    • pp.147-151
    • /
    • 2009
  • A wideband correlator, with 45% relative bandwidth is proposed at the frequency range of 3.1-5.1GHz. The structures of the correlator components such as the delay line and the Wilkinson power divider are designed to be realized in transmission line form using the Agilent's Advanced Design System (ADS). The correlator made by using three unique wideband 3-dB couplers, rat-race coupler and one 3-dB wilkinson power divider to reach the required bandwidth. The insertion loss, amplitude imbalance and phase imbalance between ports are presented. The proposed correlator makes compact size better than correlator of conventional structure.

A Study on the Affected of DC-Link Voltage Balance Control of the Vienna Rectifier Linked With the Input Series Output Parallel LLC Converter (직렬 입력 병렬 출력 연결된 LLC 컨버터를 갖는 비엔나 정류기의 DC 링크 전압 평형 제어에 관한 연구)

  • Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.3
    • /
    • pp.205-213
    • /
    • 2021
  • Due to the advantage of reducing the voltage applied to the switch semiconductor, the input series and output parallel combination is widely used in systems with high input voltage and large output current. On the other hand, the LLC converter is widely used as a high-efficiency power converter, and when connected by ISOP combination, there is a possibility that input voltage imbalance may occur due to a mismatch of passive devices. To avoid damaging the switching device, this study analyzed the DC-link voltage imbalance of a high-capacity supply using an ISOP LLC converter. In addition, the case where DC-link unbalance control was applied and the case not applied was analyzed respectively. Based on this analysis, an initial start-up algorithm was proposed to prevent input power semiconductor device damage due to DC-link over-voltage. The effectiveness of the proposed algorithm has been verified through simulations and experiments.

Design and implementation of power-controlled front-end module for direct conversion receiver (전력제어 직접변환수신 6단자 소자 설계 및 제작)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2391-2396
    • /
    • 2010
  • The power-controlled six-port element that can control the local oscillator signal power and receiving RF signal power was designed and implemented in this paper. The direct conversion six-port element configuration was proposed, which provides the constant six-port output power by controlling the six-port input power with various signal strength. The direct conversion six-port element protects the power detector element of six-port receiver from the saturation status and compensates the transmission performance degradation. For implementation of power-controlled six-port element, the power-controlled six-port element including the power controller was analyzed. The implemented power-controlled six-port element shows the power control capability of 36 dB and gain imbalance of about 1.6 dB, phase imbalance of about $4^{\circ}$ in the frequency range of 1.69 GHz. The measured results show the good performance as direct conversion front-end element.

Antecedents and consequences of trust and commitment in apparel manufacturer-contractor relationships: The moderating role of length of relationship (국내 패션기업과 협력업체와의 관계에서 신뢰와 몰입에 영향을 미치는 변인: 관계 기간의 조절 효과)

  • Park, Na Ri;Park, Jae-Ok
    • The Research Journal of the Costume Culture
    • /
    • v.21 no.2
    • /
    • pp.220-233
    • /
    • 2013
  • This study examined regarding the moderating effect of length of relationship in the relationship among the antecedent variables (i.e., specific investment, opportunistic behavior, communication, uncertainty, interdependence, power imbalance, shared value, and flexibility) of trust and commitment, trust and commitment and firm performance and relationship satisfaction. A total of 128 apparel manufacturers participated in this study. Flexibility exerted the most positive effect on trust in short-term relationship, followed by specific investment. And opportunistic behavior was found to exert negative effect on trust. Commitment was found to be most negatively affected by power imbalance, followed by interdependence. Trust was shown to be significantly affected by communication, shared value and flexibility in short-term relationship. In the case of long-term relationship, commitment was shown to be significantly affected by uncertainty, interdependence, power imbalance and flexibility. Firm performance was positively affected by both trust and commitment. As for the effect of trust and commitment on relationship satisfaction, relationship satisfaction was also affected by both trust and commitment. In case the length of relationship, firm performance was affected by both trust and commitment. As for the effect of trust and commitment on relationship satisfaction, relationship satisfaction was also affected by both trust and commitment. The result of this research provides valuable data for making a concrete suggestion regarding the strategy for improving trust and commitment for the sake of the desirable relationship between apparel manufacturers and contractors.

Control of Railway Power Quality Conditioner for AC Electrified Railway Systems (교류 전기철도 급전시스템을 위한 철도용 전기품질 보상장치의 제어방법)

  • Park, Han-Eol;Song, Joong-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.48-54
    • /
    • 2010
  • The AC electrified railway systems have the power quality problems such as the harmonic distortion, the reactive power and the three-phase imbalance because of the electrical load characteristics of locomotives, which are non-linear single-phase. These power quality problems have a bad effect on not only AC electrified railway systems but also other electric systems connected together. The RPQC (railway power quality conditioner) can compensate such power quality problems in the AC electrified railway systems. In this paper, a novel RPQC control method based on SRF (synchronous-reference-frame) control is proposed. The proposed RPQC control method can compensate effectively the harmonic currents, the reactive power and the load imbalance. The validity and the effectiveness of the proposed RPQC control method are illustrated through the simulations.

Effect of Correction to Muscle Imbalance in Lower Limbs according to Reduction of Weight Bearing Methods of Four Point of Horizontal Shaft (횡축 4정점 체중부하 감소기법 이용한 하지 근력불균형 개선에 미치는 효과)

  • Kang, S.R.;Kim, U.R.;Jeong, H.C.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.101-107
    • /
    • 2013
  • In this paper, we were to investigate effect of correction to muscle imbalance in lower limbs according to reduction of weight bearing methods of four point of horizontal shaft using two-belt treadmill. Participants were divided to two group according to each ten peoples who have difference of muscle function in left and right legs over 20%. Experiment progressed forty minutes a day three days a week, total four weeks and we estimated the maximal peak torque and average power for testing joint torque in hip, knee and ankle. The results showed that the correction effect of muscle imbalance to the maximal muscle strength was the most effective in hip joint. Also in knee joint, correction effect of muscular reaction was the most effective too. We thought that reduction of weight bearing methods could be positive effect to correct muscle imbalance in lower limbs.

  • PDF

A Study on Error Compensation for Quadrature Modulator in Frequency Direct Conversion Method (주파수 직접변환방식의 직교변조부 에러보정에 관한 연구)

  • 백주기;이일규;방성일;진년강
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.542-551
    • /
    • 1998
  • In this study, a method of error compensation for channel gain imbalance, phase imbalance and local oscillator leakage in the modulator of frequency direct conversion is suggested. The compensation of channel imbalance can be carried out by using the received power after transmitting test signal. By applying this method, the phase imbalance conversion with frequency can be easily compensated since this method is rarely affected by the transmission channel. It is confirmed that the algorithm proposed in this study(iteration coefficient=11) converges faster than conventional algorithm(iteration coefficient=43). From the numerical results, the DC-offset, channel gain, phase imbalance compensation coefficient and iteration number converges into($f_1$=0.0199999, $f_2$=-0.050001, $C_{22}$=0.9133, $C_{12}$=-0.0524, N=13) when the local oscillator leakage is not considered. However, it converges into($f_1$=-0.02, $f_2$=-2.2476, $C_{22}$=0.9133, $C_{12}$=-0.0524, N=16) when the local oscillator leakage is considered.

  • PDF

Operating Characteristics of Superconducting Fault Current Limiters Connected in Series by Shunt Resistors (직렬연결된 초전도 한류기의 분로저항에 의한 동작특성)

  • Hyun, Ok-Bae;Choi, Hyo-Sang;Kim, Hye-Rim;Lim, Hae-Ryong;Kim, In-Seon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.11
    • /
    • pp.737-741
    • /
    • 2000
  • We fabricated resistive superconducting fault current limiters (SFCL) based on YBCO thin films grown on 2-inch diameter $Al_2O_3$ substrates. Two SFCLs with nearly identical properties were connected in series to investigate simultaneous quench. There was a slight difference in the rate of voltage increase between two SFCL units when they were operated independently. This difference resulted in significantly imbalanced power dissipation between the units. This imbalance was removed by connecting a shunt resister to an SFCL in parallel. The appropriate values of shunt resistance were 80 ${\Omega}$ at 75 $V_rms$ and 110 ${\Omega}$ at 120 $V_rms$, respectively. Increased power input at high voltages also reduced the initial imbalance in power dissipation, but with increase in film temperature to higher than 200 K.

  • PDF