• 제목/요약/키워드: Power Generation

검색결과 7,175건 처리시간 0.033초

태양광 발전시스템의 모듈온도와 일사량에 따른 전력 패턴 분석 (Power Pattern Analysis According to Irradiation and Module Temperature for Photovoltaic Systems)

  • 홍정희;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.174-176
    • /
    • 2009
  • This paper aims to investigate generation conditions necessary for the most efficient generation by measuring electricity power under various irradiation conditions, since the photovoltaic generation system has high costs and low efficiency. This thesis aims to investigate generation conditions necessary for the most efficient generation by measuring electricity power under various irradiation conditions, since the photovoltaic generation system has high costs and low efficiency. Although the generation power increased with the irradiation, the former did not vary directly as the latter. This meant that the variation of the generation power was concerned in the temperature of a module, the ambient temperature, and the directions of irradiation as well as the irradiation. As for the monthly accumulated irradiation and monthly accumulated power, the maximum irradiation and generation power were observed in May and October and the irradiation, the power and the accumulated generation power were all the highest in spring, followed by fall, summer and winter.

  • PDF

배전시스템 운영계획을 위한 신재생에너지원 발전량 예측 방법 (Renewable Power Generation Forecasting Method for Distribution System: A Review)

  • 조진태;김홍주;류호성;조영표
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권1호
    • /
    • pp.21-29
    • /
    • 2022
  • Power generated from renewable energy has continuously increased recently. As the distributed generation begins to interconnect in the distribution system, an accurate generation forecasting has become important in efficient distribution planning. This paper explained method and current state of distributed power generation forecasting models. This paper presented selecting input and output variables for the forecasting model. In addition, this paper analyzed input variables and forecasting models that can use as mid-to long-term distributed power generation forecasting.

조력발전과 해류발전을 겸하는 통합발전시스템 타당성 연구 (Feasibility Study on the Integration Power System combining Tidal Power Generation and Ocean Current Power Generation)

  • 장경수;이정은
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.611-614
    • /
    • 2009
  • The present paper relates to an integration power system combining tidal power generation and ocean current power generation, and more particularly, to an integration power system combining a tidal power plant and two ocean current power parks, which is capable of increasing the operating rate of power facilities and efficiently generating electrical energy by using incoming seawater into the lake through turbine generators of a tidal power plant or fast flow of seawater discharged to a sea side through sluice gates of a tidal power dam. It is shown that the integration power system is a new promising ocean power system and the ocean current turbine generators in the ocean current power parks of the integration power system are smaller in size and larger in power generation capacity compared with the tidal current turbine generators in the ocean.

  • PDF

복합발전 풍력-디젤 하이브리드 시스템 설치 지역의 전력품질 분석 (Power Quality Analysis of Wind-Diesel Hybrid Generation System Installation Area)

  • 안해준;김현구;김석우;고석환;장길수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.539-541
    • /
    • 2009
  • A severely cold weather condition of King Sejong Station, Antarctica becomes a very severe condition for an installation/operation of wind generation system. When the existing wind generation system works, it may cause a damage and destruction of wind generation system and can bring about big problems in terms of the power quality. Accordingly, it is essential to obtain technologies for the installation and operation of small wind generation system for the polar region's wind generation, and to assess and demonstrate the performance in the severely-cold environment and the polar wind generation system's development, supplementation, alteration. Also, as the available power of King Sejong Station, Antarctica, the diesel generator has been mainly used, and the wind generator has been used in the hybrid form. Wind generation and diesel generation has the different load following control each other. In the wind generation, the generated power very rapidly changes according to the change of the velocity of the wind. On the other hand, the diesel generation shows very gentle change in the velocity of output. Therefore, the study is intended to analyze the 10kw small wind generator-diesel generator's power quality of King Sejong Station, Antarctica, which is the hybrid system installation area.

  • PDF

RDF발전에 의한 열효율향상 및 $CO_2$삭감효과에 대한 평가 (An Evaluation on the Effect of the MSW-RDF Power Generation on the Thermal Efficiency and $CO_2$ Reduction)

  • 최갑석;최연석;김석준;권영배
    • 연구논문집
    • /
    • 통권31호
    • /
    • pp.45-51
    • /
    • 2001
  • One of emerging technologies under development in the advanced countries is considered as RDF(Refuse Derived Fuel) power generation, which could meet both the requirement of an alternative energy resource utilization and $CO_2$ reduction. This paper deals with the effect to the thermal effiency and CO2 reduction of RDF firing power generation. The statistical data of domestic MSW generation in last year in small and medium cities for evaluating the merits of the RDF power generation were used. The analysis for RDF power generation compared to the existing incinerator w/o(or w/) power generation shows around 20.6%(10.0%) up in the total thermal efficiency and 57.0%(31.4%) up in the $CO_2$ reduction respectively.

  • PDF

풍력 발전 특성을 고려한 순간전압강하 평가 (Voltage Sag Assessment Considering the Characteristics of Wind Power)

  • 송영원;박창현
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1571-1577
    • /
    • 2012
  • This paper presents a method for assessing the voltage sag performance of power system involving wind power generation. Wind power generation is considered as one of the most desirable renewable energy sources. However, wind power generation have uncertain energy output and it is difficult to control the output. The existing methods of voltage sag assessment are not reflected the characteristics of wind power generation. Therefore, in order to more accurately assess the voltage sag performance, the probability of wind power operation is evaluated. In this paper, the probability is determined by combining the wind speed model with the output curve of wind turbine. The probability of wind power operation is reflected as a parameter in voltage sag assessment. The proposed method can provide more accurate results of voltage sag assessment for the case involving the wind power generation.

양수발전의 비시장 가치 추정 (Estimation of the Economic Value of Pumped Storage Power Generation in Korea)

  • 원두환
    • 아태비즈니스연구
    • /
    • 제13권1호
    • /
    • pp.263-275
    • /
    • 2022
  • Purpose - This study estimated the non-market value of pumped storage power generation using the contingent valuation method(CVM). Design/methodology/approach - CVM, a non-market value estimation method, was used. The perception of pumped storage power generation and the willingness to pay(WTP) for pumped storage power generation were investigated among 612 randomly selected households. Findings - It was analyzed that the average value per household was 7309.99 won/month, and the sources of these benefits were 1819.37 won due to the improvement of power generation efficiency, 1320.48 won due to the improvement of power system reliability, 2359.24 won due to the stabilization of electricity rates, 2110.89 won due to water resource management It was assumed that a circle occurred. If the average monthly benefit per household is expanded to cover countries across the country, it is estimated that the annual value to our society from pumped storage power generation will be KRW 1.796.6 trillion. Research implications or Originality - It is necessary to consider the operation of pumped-water power generation by reflecting the value of pumped-up power generation that is not evaluated in the market. Since Korea's electricity market is isolated in a state where it is impossible to connect with other countries, it may be vulnerable to a stable electricity operation system. Therefore, there is a need for a facility that can stably secure reserve power and produce power quickly when necessary. If pumped-water power generation is actively used for power operation, a more stable power system can be secured.

Analysis of System Impact of the Distributed Generation Using EMTP with Particular Reference to Voltage Sag

  • Yeo, Sang-Min;Kim, Chul-Hwan
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권3호
    • /
    • pp.122-128
    • /
    • 2004
  • With the advent of distributed generation, power systems are fundamentally impacted in regards to stability and power quality. Distributed generation has a positive impact on system restoration following a fault, higher reliability, and mitigation of effect due to voltage sag. However, distributed generation also has a negative impact on decrease of reliability such as changes of protective device setting and mal-operation. Because bulk power systems consist of various sources and loads, it becomes complicated to analyze a power system with distributed generation. The types of distributed generation are usually classified by both rotating machinery and the inverter-based system. In this paper, distributed generation is designed by rotating machinery, and the distributed system having a model of the distributed generation is simulated using EMTP. In addition, this paper presents the simulation results according to the types of distributed generation.

Analysis of the System Impact of Distributed Generation using EMTP

  • Yeo, Sang-Min;Kim, Il-Dong;Kim, Chul-Hwan;Aggarwal, Raj
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권4호
    • /
    • pp.201-206
    • /
    • 2004
  • With the advent of distributed generation, power systems in general are impacted in regards to stability and power quality. Distributed generation has positive impacts on system restoration following a fault, higher reliability, and mitigation of effect due to voltage sag. However, distributed generation also has negative impacts on the decrease of reliability such as changes of protective device setting and mal-operation. Because bulk power systems consist of various sources and loads, it is complicated to analyze power systems that have distributed generation. The types of distributed generation usually are classified as the rotating machinery system and the inverter-based system. In this paper, distributed generation is designed as a synchronous generator, and the distribution system with its distributed generation model is simulated using EMTP. In addition, this paper shows the simulation results according to the types of distributed generation