• Title/Summary/Keyword: Power Flow problem

Search Result 419, Processing Time 0.033 seconds

A Comparative Study on Power System Harmonics for Offshore Plants (해양플랜트 전력시스템의 고조파 비교분석에 관한 연구)

  • Kim, Deok-Ki;Lee, Won-Ju;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.900-905
    • /
    • 2016
  • The field of power system harmonics has been receiving a great deal of attention recently. This is primarily due to the fact that non-linear (or harmonic-producing) loads comprise an ever-increasing portion of what is handled at a typical industrial plant. The incidence rate of harmonic-related problems is low, but awareness of harmonic issues can still help increase offshore power plant system reliability. On the rare occasion that harmonics become a problem, this is either due to the magnitude of harmonics produced or power system resonance. This harmonic study used an electrical configuration for the offloading scenario of a Floating LNG (FLNG) unit, considering power load. This electrical network configuration is visible in the electrical network load flow study part of the project. This study has been carried out to evaluate the performance of an electric power system, focusing on the harmonic efficiency of an electrically driven motor system to ensure offshore plant safety. In addition, the design part of this study analyzed the electric power system of an FLNG unit to improve the safety of operation and maintenance.

Hydraulic and Numerical Model Experiments of Flows in Circulation-Water-Pump Chambers (순환수취수펌프장 내의 흐름에 대한 수리 및 수치모형실험)

  • Yi, Yong-Kon;Cheong, Sang-Hwa;Kim, Chang-Wan
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.8 s.157
    • /
    • pp.631-643
    • /
    • 2005
  • The objective of this study is to perform hydraulic and numerical model experiments of the flows in circulation-water-pump(CWP) chambers of combined cycle power plants (CCPP) to be built and to suggest improvement plans if the flows might cause a serious problem on the operation of CWPs. Hydraulic model was constructed in a scale of 1 to 20 using acrylic sheets and a two dimensional numerical model used was RMA2. To evaluate results of Hydraulic and numerical model experiments, evaluation criteria of flow conditions in the intake canal and CWP chambers were determined. Vertical vorticities obtained from numerical simulations for the initial plan of CCPPs were qualitatively compared with results of hydraulic model experiments and the formation possibility of a large scale vortex, one of the flow evaluation criteria, was evaluated. The initial plan was found not to satisfy the flow evaluation. Nine improvement plans were devised and numerically simulated. Four alternative plans among nine improvement plans were selected and hydraulically experimented. On the ground of the results of hydraulic model experiments, a final improvement plan, one of four improvement plants, was suggested. When CWP chambers and intake canals were designed with spatial constraints, flow separating wall and guide walls were found to improve flow conditions in CWP chambers.

The Analysis of heating performance of heat pump system for agricultural facility using underground air in Jeju area - Focused on the Jeju Area - (제주지역 지하공기를 이용한 농업시설용 히트펌프시스템의 난방 성능 분석 - 제주지역을 중심으로 -)

  • Kang, Youn-Ku;Lim, Tae-Sub
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.109-114
    • /
    • 2016
  • Purpose: The underground air is the warm air discharged from the porous volcano bedrock 30-50m underground in Jeju, including excessive humidity. The temperature of the underground air is $15-20^{\circ}C$ throughout the year. In Jeju, the underground air was used for heating greenhouses by supplying into greenhouses directly. This heating method by supplying the underground air into greenhouses directly had several problems. The study was conducted to develop the heat pump system using underground air as heat source for resolving excessive humidity problem of the underground air, adopting the underground air as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) and saving heating cost for agricultural facilities. Method: 35kW scale(10 RT) heat pump system using underground air installed in a greenhouse of area $330m^2$ in Jeju-Special Self-Governing Province Agricultural Research & Extension Services, Seogwipo-si, Jeju. The inlet and outlet water temperature of the condenser, the evaporator and the thermal storage tank and the underground air temperature and the air temperature in the greenhouse were measured by T type thermocouples. The data were collected and saved in a data logger(MV200, Yokogawa, Japan). Flow rates of water flowing in the condenser, the evaporator and the thermal storage tank were measured by an ultrasonic flow meter(PT868, Panametrics, Norway). The total electric power that consumed by the system was measured by a wattmeter(CW240, Yokogawa, Japan). Heating COP, rejection heat of condenser, extraction heat of evaporator and heating cost were analyzed. Result: The underground air in Jeju was adopted as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) in 2010. From 2011, the heat pump systems using underground air as a heat source were installed in 12 farms(16.3ha) in Jeju.

GE 7FA+e DLN-2.6 Gas Turbine Combustor : Part Ⅰ Operating Condition Optimization (GE 7FA+e DLN-2.6 가스터빈 연소기 연구 : Part Ⅰ 운전조건 최적화)

  • Oh, Jeong-Seog;Kim, Min-Ki;Heo, Pil-Won;Lee, Jang-Soo;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.5
    • /
    • pp.43-50
    • /
    • 2008
  • DLN-2.6 combustion tuning was carried out for the maintenance of GE 7FA+e gas turbine at Seo-Incheon combined cycle power plant. DLN-2.6 combustion system has the higher level of yellow plume and combustion vibration problem in the initial operating mode than that of the base mode($100{\sim}160MW$). The objectives of this study are to investigate the causes of yellow plume and combustion vibration problems at the starting mode and to suggest the best operating condition for the reliable working of the real combustors. By the analysis of tuning data, we could conclude that a yellow plume is caused by the rich mixture(${\phi}{\sim}1$) in a PM 1 nozzle at mode 3($20{\sim}30MW$). In addition, the combustion vibration($120{\sim}140Hz$) might be related to the cold flow characteristics of PM 3 nozzles at mode 6B($40{\sim}45MW$).

GE 7FA+e DLN-2.6 Gas Turbine Combustor : Part II Design of Lab Scale Dump Combustor (GE 7FA+e DLN-2.6 가스터빈 연소기 연구 : Part II 모형 덤프 연소기 설계)

  • Oh, Jeong-Seog;Kim, Min-Ki;Heo, Pil-Won;Lee, Jang-Soo;Yoon, Young-Bin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.12 no.5
    • /
    • pp.51-59
    • /
    • 2008
  • DLN-2.6 combustion tuning was carried out for the maintenance of GE 7FA+e gas turbine at Seo-Incheon combined cycle power plant. DLN-2.6 combustion system has the higher level of yellow plume and combustion vibration problem in the initial operating mode than that of the base mode($100{\sim}160MW$). The objectives of this study are to investigate the causes of yellow plume and combustion vibration problems at the starting mode and to suggest the best operating condition for the reliable working of the real combustors. By the analysis of tuning data, we could conclude that a yellow plume is caused by the rich mixture(${\phi}{\sim}1$) in a PM 1 nozzle at mode 3($20{\sim}30MW$). In addition, the combustion vibration($120{\sim}140Hz$) might be related to the cold flow characteristics of PM 3 nozzles at mode 6B($40{\sim}45MW$).

TAS: TCP-Aware Sub-layer over IEEE 802.11-based wireless LANs (IEEE 802.11 기반 무선랜에서 TCP 인진서브 계층 TAS)

  • Choi, Nak-Jung;Jung, Ha-Kyung;Ryu, Ji-Ho;Seok, Yong-Ho;Choi, Yang-Hee;Kwon, Tae-Kyoung
    • Journal of KIISE:Information Networking
    • /
    • v.33 no.5
    • /
    • pp.355-368
    • /
    • 2006
  • This paper introduces a new split-TCP approach for improving TCP performance over IEEE 802.11-based wireless LANs. TCP over wireless LANs differently from wired networks is not aggressive, which is a fundamental reason for poor performance. Therefore, we propose TAS (TCP-Aware Sub-layer) to migigate this problem. Our scheme extends the split-connection approach that divides a connection into two different connections at a split point such as an access point (AP). Using TAS, a wireless node emulates TCP ACK packets using MAC ACK frames, instead of receiving real TCP ACK packets. We compared TAS with both normal TCP and I-TCP (Indirect TCP) by NS2 simulation. Results show that TAS achieves higher throughput, more fair resource allocation and, in power-saving mode, shorter delays.

PILOT INJECTION OF DME FOR IGNITION OF NATURAL GAS AT DUAL FUEL ENGINE-LIKE CONDITIONS

  • MORSY M. H.;AHN D. H.;CHUNG S. H.
    • International Journal of Automotive Technology
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • The ignition delay of a dual fuel system has been numerically investigated by adopting a constant volume chamber as a model problem simulating diesel engine relevant conditions. A detailed chemical kinetic mechanism, consisting of 28 species and 135 elementary reactions, of dimethyl ether (DME) with methane ($CH_{4}$) sub-mechanism has been used in conjunction with the multi-dimensional reactive flow KIVA-3V code to simulate the autoignition process. The start of ignition was defined as the moment when the maximum temperature in the combustion vessel reached to 1900 K with which a best agreement with existing experiment was achieved. Ignition delays of liquid DME injected into air at various high pressures and temperatures compared well with the existing experimental results in a combustion bomb. When a small quantity of liquid DME was injected into premixtures of $CH_{4}$/air, the ignition delay times of the dual fuel system are longer than that observed with DME only, especially at higher initial temperatures. The variation in the ignition delay between DME only and dual fuel case tend to be constant for lower initial temperatures. It was also found that the predicted values of the ignition delay in dual fuel operation are dependent on the concentration of the gaseous $CH_{4}$ in the chamber charge and less dependent on the injected mass of DME. Temperature and equivalence ratio contours of the combustion process showed that the ignition commonly starts in the boundary at which near stoichiometric mixtures could exists. Parametric studies are also conducted to show the effect of additive such as hydrogen peroxide in the ignition delay. Apart from accurate predictions of ignition delay, the coupling between multi-dimensional flow and multi-step chemistry is essential to reveal detailed features of the ignition process.

A Study on Encouragement Strategy of Electronic Commerce through Clothing Industry (의류산업을 통한 전자상거래 활성화 전략 방안 연구)

  • Seo, Shin-Lim;Lee, Hyun-Chang;Jin, Chan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.10a
    • /
    • pp.628-629
    • /
    • 2011
  • E-commerce is a kind of trade type between buyers and sellers rely on computer networks. Carried out according to certain standards of various business activities. e-commerce is based on modern information technology and network technology, financial electronic collection, management, information technology, business and trade information networks into one, aimed at logistics, capital flow and information flow of harmony and unity of the new trade, trade activities of the entire process, electronic, networking and digital. E-commerce has brought to the traditional ways of trading a huge impact, led to changes in economic structures, is a business revolution in the way and is recognized internationally as the 21st century is an important driver of economic development compared to current traditional companies. In this material, we first consider the current problem, analyze particular characteristics of clothing shopping mall to increase the purchasing power of customer. For these reasons, we describe the process for building the clothing site.

  • PDF

Determination of Flow Stress and Cutting Force Prediction of Ti-6Al-4V Material for 3D Printer using S-K Constitutive Equation (S-K 구성방정식을 이용한 프린터용 3D Ti-6Al-4V 재료의 유동응력 결정 및 절삭력 예측)

  • Park, Dae-Gyoun;Kim, Tae-Ho;Jeon, Eon-Chan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.6
    • /
    • pp.68-74
    • /
    • 2018
  • Study on the Ti-6Al-4V have been carried out using cutting simulation, and researches for cutting force and chip shape prediction have been actively conducted under various conditions. However, a 3D printer application method using Ti-6Al-4V metal powder material as a high-power method has been studied for the purpose of prototyping, mold modification and product modification while lowering material removal rate. However, in the case of products / parts made of 3D printers using powder materials, problems may occur in the contact surface during tolerance management and assembly due to the degradation of the surface quality. As a result, even if a 3D printer is applied, post-processing through cutting is essential for surface quality improvement and tolerance management. In the cutting simulation, the cutting force and the chip shape were predicted based on the Johnson-Cook composition equation, but the shape of the shear type chip was not predictable. To solve this problem, we added a damaging term or strain softening term to the Johnson-Cook constitutive equation to predict chip shape. In this thesis, we applied the constant value of the S-K equations to the cutting simulation to predict the cutting force and compare with the experimental data to verify the validity of the cutting simulation and analyzed the machining characterization by considering conditions.

Numerical Study on Slanted Cubical-Cavity Natural Convection (경사진 3차원 캐비티내 자연대류현상에 관한 수치적 연구)

  • Myong, Hyon-Kook;Kim, Jong-Eun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.9
    • /
    • pp.722-728
    • /
    • 2006
  • Natural convection flows in a cubical air-filled slanted cavity that has one pair of opposing faces isothermal at different temperatures, $T_h\;and\;T_c$, respectively, the remaining four faces having a linear variation from $T_c\;toT_h$ are numerically simulated by a solution code (PowerCFD) using unstructured cell-centered method. Special attention is paid to three-dimensional flow and thermal characteristics according to a new orientation (diamond type) for the cubical-cavity benchmark problem in natural convection. Comparisons of the average Nusselt number at the cold face are made with experimental benchmark solutions found in the literature. It is found that the code is capable of producing accurately the nature of the laminar convection in a cubical air-filled slanted cavity with differentially heated walls.