• Title/Summary/Keyword: Power Equipment Diagnosis

Search Result 182, Processing Time 0.043 seconds

Diagnosis of Processing Equipment Using Neural Network Recognition of Radio Frequency Impedance Matching

  • Kim, Byungwhan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.157.1-157
    • /
    • 2001
  • A new methodology is presented to diagnose faults in equipment plasma. This is accomplished by using neural networks as a pattern recognizer of radio frequency(rf) impedance match data. Using a realtime match monitor system, the match data were collected. The monitor system consisted mainly of a multifunction board and a signal flow diagram coded by Visual Designer. Plasma anomaly was effectively represented by electrical match positions. Twenty sets of fault-symptom patterns were experimentally simulated with experimental variations in process factors, which include rf source power, pressure, Ar and O$_2$ flow rates. As the inputs to neural networks, two means and standard deviations of positions were used ...

  • PDF

Modular Backpropagation Network to Diagnosing Plasma Processing Equipment

  • Kim, Byungwhan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.32.5-32
    • /
    • 2002
  • Processing plasmas are playing a crucial role in either depositing thin films or etching fine patterns. Any variability in process factors (such as radio frequency power or pressure) can cause a significant shift in plasma state. When this shift becomes large enough to change operating condition beyond an acceptable level, overall product quality can greatly be jeopardized. Thus, timely and accurate diagnosis of plasma malfunction is crucial to maintaining device yield and throughput. Many diagnostic systems have been developed, including HIPOCRATES [1] and PIES [2]. Plasma equipment was also diagnosed by combining neural network and expert system called Dempster-Schafer Theory [3]. A fact c...

  • PDF

A Study on Monitoring Means of Insulation deterioration of Electric Power Cable (전력케이블 열화 감시방안에 관한 연구)

  • Han, Hag-Su;Min, Kyung-Yun;Ryu, Ki-Son
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1522-1528
    • /
    • 2007
  • Electric Power cable is the apparatus that receives electric power from the Korea Electric Power Corporation and supplies electric power to electric train and annex facilities of each railway station. With substantial ripple effect during power blackout accidents, such power blackout accidents must be coped with by discriminating the status of insulation deterioration of electric power cable in advance. Discrimination of insulation deterioration of the electric power cable is normally executed while the power is disconnected and it is very difficult to discover, at early stage, the insulation deterioration of the power cable in operational state since the duration of inspection is limited. This research aims to consider method of diagnosing the insulation deterioration of electric power cable in On-Line state rather than diagnosis in Off-Line state in order to secure reliability of power supply by reducing duration of power blackout (accidental blackout and blackout during works) and by seeking reduction in equipment and manpower used in diagnosis of deterioration through prevention of the accident itself prior to occurrence through early restoration of accident due to insulation deterioration of the electric power cable and assessment of performance of the cable under operation.

  • PDF

Frequency response of Sensors for GIS insulation-diagnosis (GIS 절연진달을 위한 센서 구조별 주파수 특성)

  • Choi, Eun-Hyeok;Kim, Jung-Bae;Kim, Gi-Chai;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.413-416
    • /
    • 2007
  • If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulities to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important. The strip-senser measured impedance bandwidth of the proposed antenna is from 0.5[GHz] to 2.5[GHz] with the stop band from 0.5[GHz] to 1.7[GHz] for VSWR<2. The antenna is will play an important role for the senser for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

  • PDF

A Study on In-Process Performance Diagnosis of Hydraulic Servovalves - First Report : Position Control System - (유압서보밸브의 인-프로세스 성능 진단에 관한 연구 I - 유압실린더 위치제어계의 경우 -)

  • Kim S.D.;Kim K.H.;Song J.S.;Ham Y.B.;Lee J.C.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.1
    • /
    • pp.7-14
    • /
    • 2006
  • In this paper, an in-process diagnosis method for performance of position control servo system was studied, which was based upon null bias, slew-rate ratio and delay time measurement. Slew-rate ratio and delay time were analyzed by theoretical analysis, computer simulation and experiment. As a result of these analysis, when spool of servovalve was weared, slew-rate ratio was decreased and delay time was increased.

  • PDF

In-Process Diagnosis of Servovalve wear in Hydraulic Force Control Systems (유압실린더 힘 제어계의 인-프로세스 서보밸브 마모진단에 관한 연구)

  • Kim, S.D.;Jeon, S.H.;Chang, Y.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.6 no.2
    • /
    • pp.22-30
    • /
    • 2009
  • An in-process method of diagnosing the spool wear of hydraulic servovalves was explored. The diagnostic method discussed in this paper is for force-control hydraulic servo systems. The key principle used is that pressure sensitivity of a servovalve drops as the valve spool wears out so that it is possible to determine the spool condition by monitoring pressure sensitivity. A diagnostic algorithm was developed and evaluated through numerical simulation and experiments. Two major steps of diagnosis are the evaluation of null bias of the servovalve and the approximation of pressure sensitivity, both of which could be successfully done during normal operation of a servo system. The difference between a new servovalve and a worn valve could be clearly detected in-process, and the diagnostic test was found to be repeatable.

  • PDF

A Design of UHF-Sensor for Diagnosis of Insulator (절연진단용 UHF 센서 모델 설계)

  • Choi, Eun-Hyuck;Do, Yeong-Heoi;Kim, Gi-Chai;Kim, Lee-Kook;Lee, Kwang-Sik
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.115-117
    • /
    • 2005
  • If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulities to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important. A novel UHF(Ultra High Frequency)-microstrip antenna is presented. The measured impedance bandwidth of the proposed antenna is from 0.5[GHz] to 15[GHz] with the stop band from 0.5[GHz] to 10.7[GHz] for VSWR<2. Form results of this study, The antenna is will play an important role for the sensor for insulation diagnosis system by UHF method of real site GIS and power equipment using $SF_6$ gas.

  • PDF

Investigation on Oil-paper Degradation Subjected to Partial Discharge Using Chaos Theory

  • Gao, Jun;Wang, Youyuan;Liao, Ruijin;Wang, Ke;Yuan, Lei;Zhang, Yiyi
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1686-1693
    • /
    • 2014
  • In this paper, oil-paper samples composed of transformer windings were used to investigate the insulation degradation process subjected to partial discharge (PD), with artificial defects inside to simulate the PD induced insulation degradation. To determine appropriate test voltages, the breakdown time obtained through a group of accelerated electrical degradation tests under high voltages was firstly fitted by two-parameter Weibull model to acquire the average breakdown time, which was then applied to establish the inverse power law life model to choose advisable test voltages. During the electrical degradation process, PD signals were synchronously detected by an ultra-high frequency (UHF) sensor from inception to breakdown. For PD analysis, the whole degradation process was divided into ten stages, and chaos theory was introduced to analyze the variation of three chaotic parameters with the development of electrical degradation, namely the largest Lyapunov exponent, correlation dimension and Komogorov entropy of PD amplitude time series. It is shown that deterministic chaos of PD is confirmed during the oil-paper degradation process, and the obtained results provide a new effective tool for the diagnosis of degradation of oil-paper insulation subjected to PD.

A Study on Failure Diagnosis System for a Hydraulic Pump in Injection Molding Machinery Using Vibration Analysis (진동 분석을 이용한 사출성형기 유압펌프 결함 진단 시스템에 관한 연구)

  • Kim, Taehyun;Jeon, Yongho;Lee, Moon Gu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.3
    • /
    • pp.343-348
    • /
    • 2013
  • In line with the advances in factory automation, various pieces of equipment are now operated in batch processes controlled by computers. However, many kinds of faults can occur in complicated and large systems, which can result in low productivity and economic loss. The reliability and safety of systems have been studied because of the difficulty of determining the severity and location of faults. Therefore, it is necessary to detect and diagnose such faults in order to guarantee the reliability and safety of the equipment. In this paper, a diagnosis method for the ball bearings of a hydraulic pump is applied using a vibration signal for the maintenance of injection molding equipment. The bearings' defects are selected as a main failure mode through a failure mode and effect analysis (FMEA). Usually, there are nonlinear and impulse components of vibration in a ball bearing with faults. For the effective fault diagnosis of a ball bearing, nonlinear diagnostic methods and time-frequency analysis are applied, in addition to the methods currently used, such as power spectrum, time series analysis, and statistical methods. As a result of this study, a failure diagnosis system is provided that is useful even for non-experts. This is a condition-based method that makes it possible to resolve problems in a timely and economical way, in contrast to the prior method, which required regular but wasteful maintenance based on the experience of expensive external experts.

Establishment of Diagnostic Criteria in the Preventive Diagnostic System for the Power Transformer (전력용 변압기 예방진단새스템의 진단기준치 실정)

  • Kweon Dong-Jin;Koo Kyo-Sun;Kwak Joo-Sik;Woo Jung-Wook;Kang Yeon-Wook
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.9
    • /
    • pp.449-456
    • /
    • 2005
  • The preventive diagnostic technique prevents transformers from power failure through giving alarm and observing transformers in service. And it helps to establish the plan for optimum maintenance of the transformer as well as to find location or cause of fault using accumulated data. Data detection and experience of the preventive diagnostic system need to establish the preventive diagnostic algorithm regarding interrelationship between detected data and deterioration of equipment. Therefore in-depth analysis about the preventive diagnosis system is required. KEPCO has adopted the preventive diagnostic system at nine 345kV substations since 1997. Techniques for component sensors of the preventive diagnosis system were settled but diagnosis algorithm, diagnostic criteria and practical use of accumulated data are not yet established. This paper, to build up the base of preventive diagnostic algorithm for the Power transformer. investigated the preventive diagnostic criteria for the power transformer.