• 제목/요약/키워드: Power EL

검색결과 223건 처리시간 0.024초

원자력 발전소용 입형 사류펌프의 동적해석에 관한 연구 (A Study on Dynamic Analysis of Vertical Mixed-Flow Pump for Nuclear Power Plants)

  • 서영수;임우섭;정희택
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.71-77
    • /
    • 2006
  • This study introduces the seismic qualification of safety related equipments for nuclear power plants to verify the possibility of resonance in regard to the operating speed and the structural integrity due to external piping nozzle loads as well as seismic dynamic loads using El-Centro earthquake, which was occurred in the 1940's previously. As a first step, it is necessary to investigate the natural frequency of the vertical mixed flow pump in order to determine whether static or dynamic equipment comparing with seismic cut-off frequency, 33hz. Also the normal mode analysis was carried out with the introduction of seismic redesign straint at the middle of vertical pump to increase the natural frequency. In terms of structural integrity, the application of static analysis with normal, upset and faulted nozzle loads event was presented for the comparison of material allowable stress. Also the dynamic analysis was performed to show the design adequacy through the application to the case of El-Centro earthquake.

  • PDF

Computer Modeling, Characterization, and Applications of Gallium Arsenide Gunn Diodes in Radiation Environments

  • El-Basit, Wafaa Abd;El-Ghanam, Safaa Mohamed;Abdel-Maksood, Ashraf Mosleh;Kamh, Sanaa Abd El-Tawab;Soliman, Fouad Abd El-Moniem Saad
    • Nuclear Engineering and Technology
    • /
    • 제48권5호
    • /
    • pp.1219-1229
    • /
    • 2016
  • The present paper reports on a trial to shed further light on the characterization, applications, and operation of radar speed guns or Gunn diodes on different radiation environments of neutron or g fields. To this end, theoretical and experimental investigations of microwave oscillating system for outer-space applications were carried out. Radiation effects on the transient parameters and electrical properties of the proposed devices have been studied in detail with the application of computer programming. Also, the oscillation parameters, power characteristics, and bias current were plotted under the influence of different ${\gamma}$ and neutron irradiation levels. Finally, shelf or oven annealing processes were shown to be satisfactory techniques to recover the initial characteristics of the irradiated devices.

제전기용 고성능 원격 감시 장치의 개발 (Development of Remote Monitoring System for Ionizer)

  • 박철영
    • 한국산업정보학회논문지
    • /
    • 제14권5호
    • /
    • pp.131-137
    • /
    • 2009
  • 제전기는 정전기를 제거하는 장치로서 평판디스플레이, 유기 EL 등의 제조 공정에서 사용하는 장치이다. 본 논문에서는 상위 컴퓨터와 다수의 제전기간에 통신이 가능하며, 각 제전기의 전원 및 제전 상태를 독립적으로 제어가 가능한 제전기용 고성능 원격 감시 장치를 개발하였다. 실험을 통하여 제어기의 핵심적인 기능인 유니트 접속, 이온발생량, 대전량, 경보상태, 그리고 제전상태가 PC와 제어기 사이에 정상적으로 송수신 되는 것을 확인하였다. 개발된 장치는 TFT-LCD, PDP, 유기 EL 등 평판제조 산업에 필요한 제전기를 고성능으로 원격 감시하는 시스템에 활용이 기대된다.

Modeling of a Four-Quadrant Switched Reluctance Motor Drive on EMTDC/PSCAD

  • El-Samahy, Ismael;Marei, Mostafa I.;El-Saadany, Ehab F.
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.68-78
    • /
    • 2008
  • This paper introduces a complete package for SRM drive on Power System Computer-Aided Design/Electromagnetic Transients (PSCAD/EMTDC). A three-phase SRM drive is modeled and simulated on PSCAD. The motor is modeled using an accurate nonlinear analytical model that takes into consideration the machine nonlinearities. A current control algorithm is applied for torque ripple minimization to achieve a smooth output torque which is necessary for high performance applications. The motor drive is tested for four-quadrant operations. The modeled SRM is capable of operating as a motor or generator during clockwise and counterclockwise motions. The proposed package helps in understanding the operational principles of switched reluctance motors, investigating the dynamic characteristics of SRM drives, and achieving a high performance dynamic control task.

The Fine Power Spectra of the Southern Oscillation Index and Its Components and their Implication

  • Lim, G.-H.;Suh, Y.-C.
    • 대기
    • /
    • 제25권3호
    • /
    • pp.559-568
    • /
    • 2015
  • As is evident from its definition, Southern Oscillation Index variability conformed to a combination of the variations of Darwin and Tahiti pressure. Over the El-$Ni{\tilde{n}}o$ Southern Oscillation spectra, the Darwin pressure shared variations associated with the SSN tendency while the Tahiti had a connection with the stratospheric quasi-biennial oscillation modulating annual cycle. The power peak near the 3.5-year period comprised the third harmonic of the sun and the second of the modulated annual cycle. The derived harmonics came from both sources, so the initiation of El-$Ni{\tilde{n}}o$ could be predicted more successfully when including the effects of the sun and QBO.

PWM-based Integral Sliding-mode Controller for Unity Input Power Factor Operation of Indirect Matrix Converter

  • Rmili, Lazhar;Hamouda, Mahmoud;Rahmani, Salem;Blanchette, Handy Fortin;Al-Haddad, Kamal
    • Journal of Power Electronics
    • /
    • 제17권4호
    • /
    • pp.1048-1057
    • /
    • 2017
  • An indirect matrix converter (IMC) is a modern power generation system that enables a direct ac/ac conversion without the need for any bulky and limited lifetime electrolytic capacitor. This system also allows four-quadrant operation, generation of sinusoidal output voltage waveforms with variable frequency and amplitude, and control of input power factor. This study proposes a pulse-width modulation-based sliding-mode controller to achieve unity input-power factor operation of the IMC independently of the active power exchanged with the grid, as well as a fast dynamic response. The designed equivalent control law determines, at each sampling period, the appropriate q-axis component of the modulated input current to be injected into the grid through the LC input filter. An integral term of the error is included in the expression of the sliding surface to increase the accuracy of the control method. A double space vector modulation method is used to synthesize the direction of the space vector of the input currents as required by the sliding-mode controller and the space vectors of the target output voltages. Simulation and experimental results are provided to show the effectiveness and evaluate the performance of the proposed control method.

CONTINUATION THEOREMS OF THE EXTREMES UNDER POWER NORMALIZATION

  • Barakat, H.M.;Nigm, E.M.;El-Adll, M.E.
    • Journal of applied mathematics & informatics
    • /
    • 제10권1_2호
    • /
    • pp.1-15
    • /
    • 2002
  • In this paper an important stability property of the extremes under power normalizations is discussed. It is proved that the restricted convergence of the Power normalized extremes on an arbitrary nondegenerate interval implies the weak convergence. Moreover, this implication, in an important practical situation, is obtained when the sample size is considered as a random variable distributed geometrically with mean n.

장기 신뢰성 평가를 위한 태양전지의 열충격 시험 특성에 관한 연구 (The Study on Thermal Shock Test Characteristics of Solar Cell for Long-term Reliability Test)

  • 강민수;김도석;전유재;신영의
    • 에너지공학
    • /
    • 제21권1호
    • /
    • pp.26-32
    • /
    • 2012
  • 본 연구에서는 PV(photovoltaic)모듈에서 경년에 따른 효율 저하의 원인을 분석하기 위해 셀 레벨에서의 열충격 시험을 수행하였다. 열충격 시험의 조건은 $-40^{\circ}C$에서 $85^{\circ}C$로 각각 15분씩 30분을 1사이클로 하였으며, 열충격 시험 500 사이클 동안 100 사이클 간격으로 EL분석 및 I-V분석을 수행하였다. 효율 감소율은 단결정 Bare Cell이 8%, Solar Cell이 9%였으며, 다결정 Bare Cell이 6%, Solar Cell이 13%의 감소율을 보였다. 열충격 시험 후 Solar Cell은 표면 손상으로 인한 효율저하를 확인할 수 있었다. Bare Cell의 경우 표면의 손상이 없었지만, 효율이 저하된 것을 확인할 수 있었다. 이는 Fill Factor 분석에 의해 경년 시 나타나는 누설전류에 의한 소모전력 증가로 효율 저하에 영향을 준 것으로 판단된다. 또한, Bare Cell보다 Solar Cell에서의 효율 감소율이 상대적으로 높게 나타난 결과는 표면 손상 및 소모 전력의 증가로 인해 Solar Cell 효율에 큰 영향을 미치는 것으로 판단된다. 향후 단면 분석법 및 다양한 조건의 시험 기법을 활용하여 PV모듈 뿐 아니라 Cell 레벨에서의 불규칙한 효율 및 Fill Factor의 감소 원인을 검토하고, Solar Cell에서의 효율 저하가 가속되는 원인에 대한 대책 방안 연구가 수행되어야 할 것이다.

한반도내 미세먼지 발생주기의 시공간분포 특성 (Spatial and Temporal Features of PM10 Evolution Cycle in the Korean Peninsula)

  • 장재훈;이화운;이순환
    • 한국환경과학회지
    • /
    • 제21권2호
    • /
    • pp.189-202
    • /
    • 2012
  • Power spectral analysis for $PM_{10}$ observed at 10 cities in the Korean Peninsula from 2004 to 2010 was carried out to examine the spatial and temporal features of $PM_{10}$ evolution cycle. The power spectrum analysis proposed 9 typical cycles (0.5 day, 1day, 5.4day, 8~10day, 19~21day, 26day, 56day, 180day and 365day) for $PM_{10}$ evolution and the cycles are strongly associated with dilution and transportation due to the meterological influence. The spectrum intensity of 5.4day and 26day $PM_{10}$ evolution cycles mainly depend on the advection cycles of synoptic pressures system and long-term variation of climatological forcing, respectively. The intensity of $PM_{10}$ evolution with longer temporal cycles than one day tends to be stronger in La ni$\tilde{n}$a period in comparison with that in El ni$\tilde{n}$o period. Mean of typical intensity of $PM_{10}$ evolution in La ni$\tilde{n}$a period estimated to be 30% larger than El ni$\tilde{n}$o period. Thus the global scale meteorological phenomena such as El ni$\tilde{n}$o and La ni$\tilde{n}$a also can influence the variation of wind system in the Korean Peninsula and $PM_{10}$ evolution. but global scale forcing tends to influence different manner for $PM_{10}$ evolution in accordance with its temporal cycles.

Research on the Power Drop of Photovoltaic Module’s Aging Through the Thermal Shock Test

  • Kang, MinSoo;Jeon, YuJae;Kim, DoSeok;Shin, YoungEui
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권5호
    • /
    • pp.268-273
    • /
    • 2015
  • While analyzing the specimens before and after the thermal shock test, we found that the power drop rate of the bare cell was 5.08%, while the power drop rate of the ribboned cell was 16.49%. In comparative terms, the efficiency was lower at the ribboned cell than at the bare cell. While analyzing through EL (Electroluminescence) shots and cross sections, we tried to decipher the exact cause of the power drop. Although mere color change of the cell was observed at the surface of the bare cell, no abnormality could be found inside the cell. On the surface of the ribboned cell, the short circuit of gridfinger extended from the front part of the front electrode of the ribboned cells. Therefore, cracks occurred on the surface of the cell. Cracks also appeared inside the cell. While analyzing the I-V curve, we determined an increase in the leakage current and an increase of resistances in series in the bare cell. In the ribboned cell, the resistances in parallel reduced remarkably. An increase of resistances in series could also be verified. Conclusively, we deduced that the power drop rate in the bare cell is a life span of the cell itself; aging is the cause of power drop rate in cells. In case of ribboned cell, the power drop rate was directly influenced by internal cracks and an intermetallic compound layer joining the ribbon at the front electrode.