• 제목/요약/키워드: Power Distribution Equipment

Search Result 357, Processing Time 0.184 seconds

A Technical Assessment of Possibility Sanction for Assistance to DPRK (대북 바이오가스플랜트 지원의 제재 가능성에 대한 기술적 평가)

  • Chung, Yongjin;Kwon, Yongchai
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.192-199
    • /
    • 2015
  • Under the economic banner of "self-reliance," North Korea has focused on hydro and thermal power as its main energy supply sources. However, in the face of extreme energy penury caused by machinery and material supply instability in the wake of the collapse of the former communist block as well as equipment aging and deterioration due to floods and other disasters, North Korea and international aid organizations are increasingly turning their attention toward energy source diversification. In particular, renewable energy is recognized as the best strategic energy source for North Korea and it is a decentralized energy option that is suitable in light of North Korea's power distribution networks and its pursuit of self-reliance. Biogas can contribute to improving the human rights situation of North Koreans in conjunction with an increase in food production. For this reason, renewable energy is the most promising option for an energy source that is likely to secure humanitarian aid from international organizations such as the Food and Agricultural Organization (FAO) and the World Food Programme (WFP). However, the implementation of such humanitarian aid has been hampered by rising concerns about the diversion of provided energy materials for military purposes and the disguised introduction of dual use items strategic materials as well as UN Security Council resolutions and sanctions of the international community against North Korea's military provocation, including nuclear tests and missile launches. This paper explores the possibility of solving this dilemma and proceeding with the humanitarian aid to North Korea by evaluating the potential for sanction and the risk of diversion of the possible products for biogas-related aid on the basis of the list of UN-sanctioned items.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Vacuum Web-coater with High Speed Surface Modification Equipment for fabrication of 300 mm wide Flexible Copper Clad Laminate (FCCL) (초고속 대면적 표면 처리 장치가 부착된 300 mm 폭 연성 동박적층 필림 제작용 진공 웹 코터)

  • Choi, H.W.;Park, D.H.;Kim, J.H.;Choi, W.K.;Sohn, Y.J.;Song, B.S.;Cho, J.;Kim, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.79-90
    • /
    • 2007
  • Prototype of $800{\ell}$ vacuum web coater (Vic Mama) consisting of ion source with low energy less than 250 eV for high speed surface modification and 4 magnetron sputter cathodes was designed and constructed. Its performance was evaluated through fabricating the adhesiveless flexible copper clad laminate (FCCL). Pumping speed was monitored in both upper noncoating zone pumped down by 2 turbo pumps with 2000 l/sec pumping speed and lower surface modification and sputter zone vacuumed by turbo pumps with 450 1/sec and 1300 1/sec pumping speed respectively. Ion current density, plasma density, and uniformity of ion beam current were measured using Faraday cup and the distribution of magnetic field and erosion efficiency of sputter target were also investigated. With the irradiation of ion beams on polyimide (Kapton-E, $38{\mu}m$) at different fluences, the change of wetting angle of the deionized water to polyimide surface and those of surface chemical bonding were analyzed by wetting anglometer and x-ray photoelectron spectroscopy. After investigating the deposition rate of Ni-Cr tie layer and Cu layer was investigated with the variations of roll speed and input power to sputter cathode. FCCL fabricated by sputter and electrodeposition method and characterized in terms of the peel strength, thermal and chemical stability.

The Effects of Operational Factors On the Performance of Husk Separator (왕겨풍구의 성능(性能)에 영향(影響)을 미치는 작동요인(作動要因)에 관(關)한 연구(硏究))

  • Chang, Hyun Taik;Noh, Sang Ha;Chung, Chang Joo
    • Journal of Biosystems Engineering
    • /
    • v.9 no.1
    • /
    • pp.22-33
    • /
    • 1984
  • Husk separator is an indispensable equipment in rice milling plants. However, any basic research on the designing and operating criteria of the husk separator have rarely been conducted in Korea. According to the survey results reported recently, grain loss occurs in the process of rice husk separation at custom rice milling plants in Korea and the performance of husk separator has also not been identified. With this regard this study was conducted with a typical commercial husk separator to investigate the effect of the operational factors such as feed rate, blower speed and opening ratio on the velocity distribution in the air duct and the performance of the separator. The results are summerized as follows: 1. The average wind velocity in the primary air duct increased linearly with the blower rpm and the size of air inlet port in both cases of double type and single type operations. 2. The coefficient of variation in the horizontal wind velocities in the primary air duct was the minimum when the opening ratio was 0.22 ($0.052m^2$ of air inlet port) in both cases of single type and double type operations regardless of the blower speeds used in this test. The average wind velocity at the upper part of air duct was greater by 2-5 m/s than the velocity at the bottom part in double type operation. In case of single type operation, however, the average velocity in the middle part was greater than the upper or bottom part when the opening ratio was greater than 0.74. 3. The relationship between the overall effectiveness of separation(Ed for double type and Es for single type) and the average wind velocity (Va) in the primary air duct was expressed in the following quadratic functions. $$Ed=-190.84+106.18Va-10.052Va^2$$ ($r^2$ = 0.97782) $$Es=-223.76+106.23Va-9.1935Va^2$$ ($r^2$ = 0.97029) The average wind velocity required to obtain the overall effectiveness of separation more than 80% ranged from 4.04 m/sec to 5.84 m/sec in case of double type operation, and from 4.70 m/sec to 6.20 m/sec in case of single type. 4. An optimum wind velocity can be obtained with an increase in the blower speed or the size of air inlet port as presented in Figure 8. There was a tendency that the faster the blower speed, the narrower the control range of the air inlet port. 5. The feed rates (1850kg/hr and 2100kg/hr) adopted in this experiment did not bring about a significant difference in both the overall effectiveness of separation and the power consumption. 6. The energy consumption increased cubically with the blower speed but linearly with the size of the air inlet port. On the basis of the results described in items 1, 3, and 6, it would be more economic to adjust the size of the air inlet port larger with a relatively low blower speed than to adjust the size smaller with a relatively high speed.

  • PDF

Data Acquisition System Applying TMO for GIS Preventive Diagnostic System (GIS 예방진단시스템을 위한 TMO 응용 데이터 수집 시스템)

  • Kim, Tae-Wan;Kim, Yun-Gwan;Jang, Cheon-Hyeon
    • The KIPS Transactions:PartA
    • /
    • v.16A no.6
    • /
    • pp.481-488
    • /
    • 2009
  • GIS is used to isolate large power electrical equipment using SF6 gas. While GIS has simple structure, it has few break down, relatively high reliability. But it is hard to check up faults for reason of pressure. Faults of GIS should have a ripple effect on community and be hard to recovery. Consequently, GIS imports a preventive diagnostic system to find internal faults in advance. It is most important that reliability on the GIS preventive diagnostic system, because it estimates abnormality of system by analysis result of collected data. But, exist system which used central data management is low efficiency, and hard to guarantee timeliness and accuracy of data. To guarantee timeliness and accuracy, the GIS preventive diagnostic system needs accordingly to use a real-time middleware. So, in this paper, to improve reliability of the GIS preventive diagnostic system, we use a middleware based on TMO for guaranteeing timeliness of real-time distributed computing. And we propose an improved GIS preventive diagnostic system applying data acquisition, monitoring and control methods based on the TMO model. The presented system uses the Communication Control Unit(CCU) for distributed data handling which is supported by TMO. CCU can improve performance of the GIS preventive diagnostic system by guaranteeing timeliness of data handling process and increasing reliability of data through the TMO middleware. And, it has designed to take full charge of overload on a data acquisition task had been processed in an exist server. So, it could reduce overload of the server and apply distribution environment from now. Therefore, the proposed system can improve performance and reliability of the GIS preventive diagnostic system and contribute to stable operation of GIS.

A Study on Construction and Application of Nuclear Grade ESF ACS Simulator (원자력등급 ESF 공기정화계통 시뮬레이터 제작 및 활용에 관한 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kei-Woo;Park, Jeong-Seo;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.319-327
    • /
    • 2010
  • A nuclear plant ESF ACS simulator was designed, built, and verified to perform experiment related to ESF ACS of nuclear power plants. The dimension of 3D CAD model was based on drawings of the main control room(MCR) of Yonggwang units 5 and 6. The CFD analysis was performed based on the measurement of the actual flow rate of ESF ACS. The air flowing in ACS was assumed to have $30^{\circ}C$ and uniform flow. The flow rate across the HEPA filter was estimated to be 1.83 m/s based on the MCR ACS flow rate of 12,986 CFM and HEPA filter area of 9 filters having effective area of $610{\times}610mm^2$ each. When MCR ACS was modeled, air flow blocking filter frames were considered for better simulation of the real ACS. In CFD analysis, the air flow rate in the lower part of the active carbon adsorber was simulated separately at higher than 7 m/s to reflect the measured value of 8 m/s. Through the CFD analyses of the ACSes of fuel building emergency ventilation system, emergency core cooling system equipment room ventilation cleanup system, it was confirmed that all three EFS ACSes can be simulated by controlling the flow rate of the simulator. After the CFD analysis, the simulator was built in nuclear grade and its reliability was verified through air flow distribution tests before it was used in main tests. The verification result showed that distribution of the internal flow was uniform except near the filter frames when medium filter was installed. The simulator was used in the tests to confirm the revised contents in Reg. Guide 1.52 (Rev. 3).

Identification of New, Old and Mixed Brown Rice using Freshness and an Electronic Eye (신선도와 전자눈을 이용한 현미 신곡, 구곡 및 혼합곡의 판별)

  • Hong, Jee-Hwa;Park, Young-Jun;Kim, Hyun-Tae;Oh, Sang Kyun
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.63 no.2
    • /
    • pp.98-105
    • /
    • 2018
  • The sale of brown rice batches composed of rice produced in different years is prohibited in Korea. Thus, new methods for the identification of the year of production are critical for maintaining the distribution of high quality brown rice. Here, we describe the exploitation of an enzyme that can be used to discriminate between freshly harvested and one-year-old brown rice. The degree of enzyme activity was visualized through freshness test with Guaiacol, Oxydol, and p-phenylenediamine reagents. With electronic eye equipment, we selected 29 color codes for identifying new brown rice and old brown rice. The discrimination power of selected color codes showed a minimum of 0.263 to a maximum of 0.922 and an average value of 0.62. The accuracy with which new brown rice and old brown rice could be identified was 100% in principal component analysis (PCA) and discriminant function analysis (DFA). The DFA analysis had greater discriminatory power than did the PCA analysis. A verification test using new brown rice, old brown rice, or a mixture of the two was then performed to validate our method. The accuracy of identification of new and old brown rice was 100% in both cases, whereas mixed brown rice samples were correctly classified at a rate of 96.9%. Additionally, in order to test whether the discriminant constructed in winter can be applied to samples collected in summer, new and old brown rice stored for 8 months were collected and tested. Both new and old brown rice collected in summer were classified as old brown rice and showed 50% identification accuracy. We were able to attribute these observations to changes in enzyme content over time, and therefore we conclude, it will be necessary to develop discriminants that are specific to distinct storage periods in the near future.