• 제목/요약/키워드: Power Capacity

검색결과 4,198건 처리시간 0.028초

싸이리스터 컨버터부하를 가지는 병렬형 능동전력필터 용량에 관한 연구 (A Study on the capacity of shunt type active power filter with a thyristor converter load)

  • 박노중;정숭기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2470-2474
    • /
    • 1999
  • The main drawback of parallel type active power filters (APFs) is the large capacity required for harmonic compensation. This paper evaluates the APF capacity requirement for harmonic/reactive power compensation for thyristor converter load. Theoretically achievable maximum power factor under partial load is evaluated. it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current, while maintaining the filtering performance with an acceptable total harmonic current level. the minimum capacity requirement of APF with current limiting is evaluated as a function of the firing angle of thyristor converter and short circuit ratio(SCR).

  • PDF

산업용 연축전지의 잔존용량 산출 알고리즘(Algorithm)에 관한 연구 (STUDY ON ALGORITHM FOR CALCULATION REMAINING CAPACITY OF INDUSTRIAL LEAD-ACID BATTERY)

  • 임규령;전순용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2187-2189
    • /
    • 2001
  • The proposed algorithm has produced the rules of relationship between the load voltage, current, discharging electric power and ampere-hours, electric power capacity of battery on the basis of the data. Which were acquired through the battery discharging experiment that is defined by the battery's ambient temperature and various load conditions. Especially, by calculating the parameter of second order polynomial equation relation between the remaining capacity and the electric power, the algorithm is proposed adapting for the discharging pattern. And as the depth of discharging is increasing, the calculation-method of electric power is applied to decrease the accumulated error in the calculation method of capacity accumulation. Also, the proposed algorithm has compensated the temperature considering the capacity change of battery to the temperature.

  • PDF

전력계통 주파수응답 기여도 기반의 전기저장장치 주파수추종서비스 유효용량 산정 (Effective Capacity Calculation of the Electrical Energy Storage providing the Primary Frequency Control Service based on the Contribution to the Frequency Response of Power Systems)

  • 임현옥;최우영;권한나;국경수
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1561-1567
    • /
    • 2017
  • This paper calculates the effective capacity of EES providing the primary frequency control service based on its contribution to the frequency response of the power system. The amount of governor response from conventional generators which can be replaced by the primary frequency control from EES keeping the frequency response of the power system is defined as the effective capacity. The proposed method for calculating the effective capacity of EES is verified through case studies employing Korean power system. Furthermore, the application of the effective capacity of EES to power system operation is also discussed.

전력보상설비의 상호 협조제어에 따른 운영여유용량의 확보 (Securing Operation Margin Capacity as Coordination Control among the Power Compensation Equipments)

  • 이상덕;백영식
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1011-1016
    • /
    • 2010
  • It is an important issue to electric power system operations that it can reliably supply large-capacity power to consumption area as due to increasing power demand growth. For this purpose, The FACTS equipment based on Power IT technology with the existing mechanical compensators has been applied to power system. Therefore we suggest on this paper that a plan for coordination control of multiple power compensation equipment in order to increase the utilization of each facility and secure operation margin capacity. As the result of simulation, it is possible to cope actively with a suddenly changed power system. This helps greatly for the voltage stability and supply reliability in a suddenly changed power system.

계통유연자원을 활용한 분산에너지 계통접속 한계용량 증대 기술 (Distributed Energy System Connection Limit Capacity Increase Technology Using System Flexible Resources)

  • 박정민
    • 통합자연과학논문집
    • /
    • 제16권4호
    • /
    • pp.139-145
    • /
    • 2023
  • Due to changes in the distribution system and increased demand for renewable energy, interest in technology to increase the limit capacity of distributed energy grid connection using grid flexible resources is also increasing. Recently, the distribution system system is changing due to the increase in distributed power from renewable energy, and as a result, problems with the limited capacity of the distribution system, such as waiting for renewable energy to connect and increased overload, are occurring. According to the power generation facility status report provided by the Korea Power Exchange, of the total power generation capacity of 134,020 MW as of 2021, power generation capacity through new and renewable energy facilities is 24,855 MW, accounting for approximately 19%, and among them, power generation through solar power accounts for a total portion of the total. It was analyzed that the proportion of solar power generation facilities was high, accounting for 75%. In the future, the proportion of new and renewable energy power generation facilities is expected to increase, and accordingly, an efficient operation plan for the distribution system is needed. Advanced country-type NWAs that can integrate the operation and management of load characteristics for each line of the distribution system, power distribution, regional characteristics, and economic feasibility of distributed power in order to improve distribution network use efficiency without expanding distribution facilities due to the expansion of renewable energy. An integrated operating system is needed. In this study, in order to improve the efficiency of distribution network use without expanding distribution facilities due to the expansion of renewable energy, we developed a method that can integrate the operation and management of load characteristics for each line of the distribution system, power distribution, regional characteristics, and economic feasibility of distributed power. We want to develop an integrated operation system for NWAs similar to that of advanced countries.

전압변동과 부하량을 고려한 저압배전계통의 분산전원 설치용량 분석 (The Study on Permissible Capacity of Distributed Generation Considering Voltage Variation and Load Capacity at the LV Distribution Power System)

  • 문원식;조성민;신희상;이희태;한운기;추동욱;김재철
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.100-105
    • /
    • 2010
  • This paper describes a capacity of distributed generation which will be interconnected at low voltage distribution systems. In order to set the capacity of distributed generation, a voltage variation of distribution system is considered. Besides, the capacity of distributed generation is classified according to a capacity of pole transformer and loads. The system constructions in this paper are analyzed by using PSCAD/EMTDC. In the immediate future, it is expected to increase the installation of New and renewable energy systems which are generally interconnected to distribution power systems in the form of distributed generations like photovoltaic system, wind power and fuel cell. So the study of this kind would be needed to limit the capacity of distributed generation.

Transmission Network Expansion Planning for the Penetration of Renewable Energy Sources - Determining an Optimal Installed Capacity of Renewable Energy Sources

  • Kim, Sung-Yul;Shin, Je-Seok;Kim, Jin-O
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1163-1170
    • /
    • 2014
  • Due to global environmental regulations and policies with rapid advancement of renewable energy technologies, the development type of renewable energy sources (RES) in power systems is expanding from small-scale distributed generation to large-scale grid-connected systems. In the near future, it is expected that RES achieves grid parity which means the equilibrium point where the power cost of RES is equal to the power costs of conventional generators. However, although RES would achieve the grid parity, the cost related with development of large-scale RES is still a big burden. Furthermore, it is hard to determine a suitable capacity of RES because of their output characteristics affected by locations and weather effects. Therefore, to determine an optimal capacity for RES becomes an important decision-making problem. This study proposes a method for determining an optimal installed capacity of RES from the business viewpoint of an independent power plant (IPP). In order to verify the proposed method, we have performed case studies on real power system in Incheon and Shiheung areas, South Korea.

1.5MVA급 중용량 인버터용 IGBT 및 Stack 병렬 운전 연구 (The Study of the IGBT and Stack Parallel Operation for the 1.5MVA Medium Power Inverter)

  • 박건태;정기찬;김연달;정명길;김두식
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(1)
    • /
    • pp.402-405
    • /
    • 2004
  • In this paper, the parallel operation of the IGBT and power stack for easy capacity enlargement series in the medium power capacity inverter system of the 660V voltage class is described. The parallel operation of the IGBT and power stack for 1.5MVA medium power inverter system's design is applied. The results of the parallel operation are described in this paper. The designed stack capacity for parallel operation is 800kVA class. For 1.5MVA inverter system, the 800kVA stack is applied with 2 parallel configurations. The 800kVA stack is designed with 3 parallel configurations of the IGBT Module. In this paper, the feasibility for easy capacity enlargement series in the medium power inverter by applying the parallel operation of the IGBT and power stack is verified. The experimental results show the good characteristics for the parallel operation of the IGBT and power stack.

  • PDF

신안풍력발전소 풍력터빈의 성능저하 분석 (Analysis on Wind Turbine Degradation of the Shinan Wind Power Plant)

  • 김현구
    • 한국태양에너지학회 논문집
    • /
    • 제33권4호
    • /
    • pp.46-50
    • /
    • 2013
  • This paper investigated wind turbine degradation quantitatively by analyzing the short-term operation records of the Shinan Wind Power Plant. Instead of a capacity factor which is needed to be normalized its variability due to monthly wind speed change, this study suggests an analysis method by taking the difference between the theoretical power output calculated from the nacelle wind speed and actual power output as the quantitative index of performance degradation. For three-year SCADA data analysis of the Shinan Wind Power Plant, it was confirmed that power output degradation rate of 0.54% per year. This value is within the average reduction rate 0.4%/year~0.9%/year of normalized capacity factor of the onshore wind power plants in U.K. and Denmark; however, lower than the rate 2%/year of Canadian wind power plants.

On the Capacities of Spectrum-Sharing Systems with Transmit Diversity

  • Asaduzzaman, Asaduzzaman;Kong, Hyung-Yun
    • Journal of electromagnetic engineering and science
    • /
    • 제10권3호
    • /
    • pp.99-103
    • /
    • 2010
  • Motivated by recent works on spectrum-sharing systems, this paper investigates the effects of transmit diversity on the peak interference power limited cognitive radio(CR) networks. In particular, we derive the ergodic and outage capacities of a spectrum-sharing system with multiple transmit-antennas. To derive the capacities, peak interference power constraint is imposed to protect the primary receiver. In a CR transmitter and receiver pair with multiple antennas at the transmitter side, the allowable transmit power is distributed over the transmit-antennas to achieve transmit diversity at the receiver. We investigate the effect of this power distribution when a peak interference power constraint is imposed to protect the primary receiver. We show that the transmit diversity does not improve the ergodic capacity compared to the single-antenna system. On the other hand, the transmit diversity significantly improves the outage capacity. For example, two transmit-antennas improve the outage capacity 10 times compared to the single-antenna with a 0 dB interference constraint.