• 제목/요약/키워드: Power Balance Equation

검색결과 72건 처리시간 0.023초

On-line Generation of Three-Dimensional Core Power Distribution Using Incore Detector Signals to Monitor Safety Limits

  • Jang, Jin-Wook;Lee, Ki-Bog;Na, Man-Gyun;Lee, Yoon-Joon
    • Nuclear Engineering and Technology
    • /
    • 제36권6호
    • /
    • pp.528-539
    • /
    • 2004
  • It is essential in commercial reactors that the safety limits imposed on the fuel pellets and fuel clad barriers, such as the linear power density (LPD) and the departure from nucleate boiling ratio (DNBR), are not violated during reactor operations. In order to accurately monitor the safety limits of current reactor states, a detailed three-dimensional (3D) core power distribution should be estimated from the in-core detector signals. In this paper, we propose a calculation methodology for detailed 3D core power distribution, using in-core detector signals and core monitoring constants such as the 3D Coupling Coefficients (3DCC), node power fraction, and pin-to-node factors. Also, the calculation method for several core safety parameters is introduced. The core monitoring constants for the real core state are promptly provided by the core design code and on-line MASTER (Multi-purpose Analyzer for Static and Transient Effects of Reactors), coupled with the core monitoring program. through the plant computer, core state variables, which include reactor thermal power, control rod bank position, boron concentration, inlet moderator temperature, and flow rate, are supplied as input data for MASTER. MASTER performs the core calculation based on the neutron balance equation and generates several core monitoring constants corresponding to the real core state in addition to the expected core power distribution. The accuracy of the developed method is verified through a comparison with the current CECOR method. Because in all the verification calculation cases the proposed method shows a more conservative value than the best estimated value and a less conservative one than the current CECOR and COLSS methods, it is also confirmed that this method secures a greater operating margin through the simulation of the YGN-3 Cycle-1 core from the viewpoint of the power peaking factor for the LPD and the pseudo hot pin axial power distribution for the DNBR calculation.

한의사인력의 중장기 수급 추계 연구 (Future Demand and Supply of Physicians for Korean Medicine)

  • 김진현;배현지;이선동
    • 대한예방한의학회지
    • /
    • 제17권1호
    • /
    • pp.149-162
    • /
    • 2013
  • Objectives : This study was conducted to estimate the future demand and supply of physicians for korean medicine from 2016 year to 2026 year in order to make an adequate manpower policy in a way of keeping a balance between demand and supply. Methods : Baseline projection method and trend analysis(a polynomial log power equation model) were used in the estimation of future supply and demand respectively. We used data about the amount of oriental doctors from Ministry of Health and Welfare Statistics Yearbook and the treatment days from HIRA Statistics Yearbook. Results : It was projected that the total number of physician of Korean medicine will be 25,178 registered and 18,967 available in clinical setting. According to polynomial equation model which explained the trend of demand and had the highest score of $R^2$ among the equation models, 3,800~5,600 physician in Korean medicine will be oversupplied in 2016 year, 9,000~10,700 physicians in 2021 year and 15,700~17,000 persons in 2026 year depends on annual working days which is 265days, 255days or 239days. Log equation model also showed that overall excess supply of physician manpower in Korean medicine. Conclusions : Alternative manpower policies for Korean medicine doctors should be implemented in a way of both dwindling supplies and growing demand in Korean medical service in terms of Korean medical services utilization and improving physician's productivity.

실시간 기상상태를 고려한 가용송전용량 산정 (Assessment of Available Transfer Capability (ATC) considering Real-time Weather Conditions)

  • 김동민;배인수;김진오
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.485-491
    • /
    • 2010
  • Total Transfer Capability (TTC) should be pre-determined in order to estimate Available Transfer Capability (ATC). Typically, TTC is determined by considering three categories; voltage, stability and thermal limits. Among these, thermal limits are treated mainly in this paper on the evaluation of TTC due to the relatively short transmission line length of Korea Electric Power Corporation (KEPCO) system. This paper presents a new approach to evaluate the TTC using the Dynamic Line Rating (DLR) for the thermal limit. Since the approach includes not only traditional electrical constraints but also real-time environmental constraints, this paper obtains more cost-effective and exact results. A case study using KEPCO system confirms that the proposed method is useful for real-time operation and the planning of the electricity market.

가변속 스크롤 압축기의 운전조건의 변화에 따른 성능 해석 (Performance Analysis on the Variable Speed Scroll Compressor with Operating Conditions)

  • 박홍희;박윤철;김용찬
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.649-658
    • /
    • 2000
  • Thermodynamic modeling of low-pressure scroll compressor was developed by combining continuity and energy conservation equation. Suction gas heating was considered using energy balance inside the low pressure shell. Pressure, temperature and mass of refrigerant-22 as a function of orbiting angle were calculated by solving the governing equations using fourth order Rung-Kutta scheme. Motor efficiency was taken by experiments with a variation of frequency. The developed model was applied to the analysis of an inverter driven scroll compressor with a variation of frequency, pressure ratio and operating conditions. The model was verified with the experimental results at the same operating conditions. The developed model was adequate to predict performance of the inverter driven scroll compressor as a function of operating conditions. Calculated parameters from the model were discharge temperature, mass flow rate, power input, COP, and thermodynamic properties with respect to orbiting angle. To enhance the performance of a scroll compressor, it is essential to diminish leakage at low frequency level and improve the mechanical efficiency at high frequency level.

  • PDF

Modeling and Experimental Study of Radio-frequency Glow Discharges and Applications for Plasma Processing

  • Kang, Nam-Jun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.179-179
    • /
    • 2012
  • Low pressure radio-frequency glow discharges are investigated using theoretical modeling and various experimental diagnostic methods. In the calculations, global models and transformer models are developed to understand the chemical kinetics as well as the electrical properties such as the effective collision frequency, the heating mechanism and the power transferred to the plasma electrons. In addition, Boltzmann equation solver is used to compensate the effect of the electron energy distribution function (EEDF) shape in the global model, and the general expression of energy balance for non-Maxwellian electrons is developed. In the experiments, a number of traditional plasma diagnostic methods are used to compare with calculated results such as Langmuir probe, optical emission spectroscopy (OES), optical absorption spectroscopy (OAS) and two-photon absorption laser-induced fluorescence (TALIF). These theoretical and experimental methods are applied to understand several interesting phenomena in low pressure ICP discharges. The chemical and physical properties of low pressure ICP discharges are described and the applications of these methods are discussed.

  • PDF

다리우스 풍력터빈의 부하변동에 따른 속도제어 (Speed Control of Darrieus Wind Turbine for Load-variation)

  • 오철수
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 추계학술발표회 초록집
    • /
    • pp.110-114
    • /
    • 1995
  • 다리우스 풍력터빈의 속도설정을 터빈이 만드는 토크와 발전기가 요구하는 토크의 Balance를 통해 찾아낼 수 있음을 검토하였다. 풍속에 따른 속도-토크곡선에서 일정v곡선과 일정P곡선이 만나는 점이 터빈의 동작점으로 되며 이는 stable 및 instable이 될 수도 있다. 또한 풍속과 출력이 각각 변할 때 이 동작점이 어떻게 이동되는가 하는 점을 제시하였다.

  • PDF

ANFIS Controller틀 이용한 유도전동기 벡터제어 시스템 (Vector Control System for Induction Motor using ANFIS Controller)

  • 이학주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1051-1052
    • /
    • 2006
  • This paper deals with mathmatical of an induction motor, considering non-linearity in the torque balance equation under closed loop operation with a reference speed. A controller based on Adaptive Nuro-Fuzzy Inference System (ANFIS) is developed to minimize overshoot and settling time following sudden changes in load torque. The overall system is modeled and simulated using the Matlab/simulink and Fuzzy Logic Toolbox. The advantages of fuzzy logic and neural network based fuzzy logic controller. Required training data the ANFIS controller is generated by simulation of the anti-windup PI controller is eliminated using the ANFIS controller. The transient deviation of the response from the set reference following variation in load torque is found to be negligibly samll along with a desirable reduction in settling time for the ANFIS controller.

  • PDF

$TiB_2$ SHS 및 직접 접촉가열에 의한 동시 가압법 : 온도분포 모델링 및 공급에너지와 치밀화 관계 (Simultaneous Consolidation of Titanium Diboride with Self-Propagating High-Temperature Synthesis, Direct Contact-Heating, and Pressure: Modeling of Temperature Distribution and the Relationship between Applied Energy and Densification)

  • 정진근;조건;이형복
    • 한국세라믹학회지
    • /
    • 제32권7호
    • /
    • pp.817-824
    • /
    • 1995
  • TiB2 was simultaneously synthesized and densified with concurrent self-propagating high-temperature synthesis and direct contact-heating by electrcial power input and pressure. Density of TiB2 synthesized by self-propagating high-temperature synthesis and consolidated simultaneously by direct contact-heating and pressure was maximum 80% of the theoretical density (4.52g/㎤). Temperature profile was analyzed by solving heat balance equation with numerical method (FTCS method). The temperature of the sample was sufficiently raised to that temperature sufficient to be densified. It was ascertained that the density of the SHS synthesized TiB2 is exponentially proportinal to the input thermal energy per mass.

  • PDF

최적제어이론에 의한 원자로 제어봉속도의 설계 (The Control Rod Speed Design for the Nuclear Reactor Power Control Using Optimal Control Theory)

  • Lee, Yoon-Joon
    • Nuclear Engineering and Technology
    • /
    • 제26권4호
    • /
    • pp.536-547
    • /
    • 1994
  • 본 논문에서는 최적제어기법을 이용한 원자로 출력 제어시스템을 다루었다. 시스템 변수들을 상태변수로 표시하면 관측치 뿐만 아니라 시스템 내부의 모든 상태변수를 동시에 다룰 수 있으므로 설계의 자유도가 증가될 수 있다. 따라서 본 논문에서는 원자로의 동특성식과 열수력학적 에너지 평형식을 사용하여 원자로를 모델링한 후 이를 상태변수로 나타내었다. 다음으로는 LQR 및 LQG 시스템을 설계하여 제어봉 및 출력의 거동을 동시에 만족시킬 수 있는 설계조건을 결정하였다. 또한 서보 시스템의 설계를 위해 보통의 휘드백 시스템과 차수를 증가시킨 레귤레이팅 시스템을 만들어 비교하였으며 그 결과 증가차수 레귤레이팅 시스템이 보통의 휘드백 시스템에 비해 우수한 제어 특성이 있음을 알 수 있었다.

  • PDF

Estimation of 3D active earth pressure under nonlinear strength condition

  • Zhang, D.B.;Jiang, Y.;Yang, X.L.
    • Geomechanics and Engineering
    • /
    • 제17권6호
    • /
    • pp.515-525
    • /
    • 2019
  • The calculation of active earth pressure behind retaining wall is a typical three-dimensional (3D) problem with spatial effects. With the help of limit analysis, this paper firstly deduces the internal energy dissipation power equations and various external forces power equations of the 3D retaining wall under the nonlinear strength condition, such as to establish the work-energy balance equation. The pseudo-static method is used to consider the effect of earthquake on active earth pressure in horizontal state. The failure mode is a 3D curvilinear cone failure mechanism. For the different width of the retaining wall, the plane strain block is inserted in the symmetric plane. By optimizing all parameters, the maximum value of active earth pressure is calculated. In order to verify the validity of the new expressions obtained by the paper, the solutions are compared with previously published solutions. Agreement shows that the new expressions are effective. The results of different parameters are given in the forms of figures to analysis the influence caused by nonlinear strength parameters.