• Title/Summary/Keyword: Power Amplitude

Search Result 1,053, Processing Time 0.032 seconds

Space Voltage Vector Pulse Width Modulation for 2-Phase Inverter (2상 인버터를 위한 공간 전압벡터 방식)

  • 장도현;박재권
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.280-286
    • /
    • 1998
  • In this paper, space voltage vector pulsewidth modulation for 2-phase inverter is proposed. When this method is appled to 2-phase induction motor, the phase difference of voltage between phase A and B is fixed at $90^{\circ}$and amplitude of voltage of phase Ais same with that of phase B. This method have advantages over low-power servo system because this is simple method comparing to 3-phase space vector method which requires d-q transform.

  • PDF

A NEW SINGLE-PHASE Z-SOURCE CYCLOCONVERTER

  • Khai, Nguyen Minh;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.318-320
    • /
    • 2007
  • Single-phase cycloconverters are widely used for ac-ac power conversion especially for speed control of ac drives. In this paper, a new single-phase to single-phase Z-source cycloconverter topology is proposed. The proposed single-phase Z-source cycloconverter can boost to a desired voltage with various frequency. Thus, it is called a frequency step-down and amplitude voltage step-up converter. The operating principle of the proposed topology is presented. Analysis and simulation for this single-phase Z-source cycloconverter are also presented.

  • PDF

A New Control Method for Single-Phase Active Power Line Contioners (단상 능동 전력 조절 장치를 위한 새로운 제어기법)

  • 서영조
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.155-158
    • /
    • 2000
  • A new control method for single-phase shunt active power line conditioners(APLC's) operated under zero average power consumption is proposed in this paper. The amplitude of the sinusoidal source current which is in-phase with the source voltage can be determined from the average value of the instantaneous load power. Then the command current for the shunt APLC is obtained by subtraction the source current from the load current. Neither bulky filter nor time-consuming computation is required. The shunt power compensator supplies all the harmonics of he load current and the source only supplies the fundamental component,. Experimental results on a prototype verify the feasibility of the presented scheme,

  • PDF

Diagnosis of Chatter Vibration using Frequency Domain in a Milling Process (밀링 공정시 주파수 영역을 이용한 채터 진동의 진단)

  • 김문기
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.3
    • /
    • pp.12-18
    • /
    • 2001
  • Frequency domain has been used to detect chatter vibration and to decide commencing point of chatter for the milling processes. For this, power spectrum of accelerations signal is analyzed in the frequency domain. Also, the power spectrum and surface roughness are measured, compared, and evaluated according to the depth of cut by experimental works. As a results, it is known that the commencing point of chatter can be decided the behavior of the maximum amplitude of the power spectrum of acceleration signal and there is a correlation between the power spectrum of acceleration signal and the surface roughness. In conclusion, the power spectrum of acceleration signal can be used as a useful information for detec-tion and estimation of chatter vibration in machining.

  • PDF

Active Power Filter Compensating for Source Voltage Unbalance/Current Harmonics and Power Factor Correction (전원 전압의 불평형과 고조파 전류 보상 및 역률 개선 기능을 가지는 능동전력 필터)

  • Lee Jong-Kun;Seok Jul-Ki;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.787-790
    • /
    • 2004
  • In this paper, a novel control scheme compensating for source voltage unbalance and current harmonics and power factor correction in unified active power filter systems combined with shunt passive filters is proposed, where no low/high-pass filter are used in deriving the reference voltage for compensation. Using digital all-pass filters, the phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage. The amplitude of d-axis current in a series filter is controlled as zero for power factor correction. The validity of the proposed control scheme has been verified by experimental results.

  • PDF

Adaptive Over Current Relay for power systems having Decentralized Generator (분산전원용 적응형 과전류 계전기)

  • Kim, Hyung-Kyu;Song, Hwang-Bin;Ahn, Jong-Pil;Jeong, Cheal-Hyun;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.195-196
    • /
    • 2008
  • Output of wind generators are changed by windy level. The change of the output also affects the amplitude of fault current. And this fault current causes OCR's mal-operation. To solve the problem, this paper adopts that Over Current Relay adapted for Decentralized generator algorithm.

  • PDF

The study on Estimate of Tidal Power Using Matlab T-tide Based on Tide Prediction (Matlab T-tide를 이용한 조위예측기반의 조력발전량 산정에 관한 연구)

  • Lee, Sung-Hun;Kwak, Hee-Jin;Kim, Jong-Deug;Lee, Eun-Chun;Kim, Ji-Chan;Jeon, Kyeong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1048-1049
    • /
    • 2015
  • The sihwa tidal power plant is the first tidal power plant in korea and the biggest of the world. The tidal power turbine is operated by tidal energy. The tidal energy is generated by the relative motion of the earth and celestial masses specially the sun and the moon, which interact via gravitational forces. The tidal power is estimated by the predicted the tidal amplitude and phase. This paper gives a process of estimate of tidal power using Matlab T-tide based on tide prediction. The proposed method is tested using actual recorded data comparing to predicted date.

  • PDF

Two-Paralleled PWM Power Amplifiers to Generate Highly Precise Gradient Magnetic Fields in MRI Systems

  • Watanabe, Shuji;Boyagoda, Prasanna;Takano, Hiroshi;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.569-574
    • /
    • 1998
  • This paper presents a two-paralleled 4 quadrant DC chopper type PWM power conversion circuit in order to generate a gradient magnetic field in the Magnetic Resonance Imaging (MRI) system. This power amplifier is connected in parallel with the conventional 4-quadrant DC chopper using IGBTs at their inputs/outputs to realize further high-power density, high speed current tracking control, and to get a low switching ripple amplitude in a controlled current in the Gradient Coils (GCs). Moreover, the power conversion circuit has to realize quick rise/fall response characteristics in proportion to various target currents in GCs. It is proposed in this paper that a unique control scheme can achieve the above objective. DSP-based control systems realize a high control facility and accuracy. It is proved that the new control system will greatly enlarge the diagnostic target and improve the image quality of MRI.

  • PDF

Control Strategy of Improved Transient Response for a Doubly Fed Induction Generator in Medium Voltage Wind Power System under Grid Unbalance

  • Han, Daesu;Park, Yonggyun;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.246-247
    • /
    • 2013
  • This paper investigates control algorithms for a doubly fed induction generator with a back-to-back three-level neutral-point clamped voltage source converter in medium voltage wind power system under unbalanced grid conditions. Control algorithms to compensate for unbalanced conditions have been investigated with respect to four performance factors; fault ride-through capability, instantaneous active power pulsation, harmonic distortions, and torque pulsation. The control algorithm having zero amplitude of torque ripple shows the most cost-effective performance concerning torque pulsation. The least active power pulsation is produced by control algorithm that nullifies the oscillating component of the instantaneous stator active and reactive power. Combination of these two control algorithms depending on the operating requirements and depth of grid unbalance presents most optimized performance factors under the generalized unbalanced operating conditions leading to high performance DFIG wind turbine system. The proposed control algorithms are verified through transient response in the simulation.

  • PDF

Single-Stage Double-Buck Topologies with High Power Factor

  • Pires, Vitor Fernao;Silva, Jose Fernando
    • Journal of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.655-661
    • /
    • 2011
  • This paper presents two topologies for single-stage single-phase double-buck type PFC converters, designed to operate at high power factor, near sinusoidal input currents and adjustable output voltage. Unlike the known buck type PFC topologies, in which the output voltage is always lower than the maximum input voltage, the proposed converters can operate at output voltages higher than the ac input peak voltage. A reduced number of switches on the main path of the current are another characteristic of the two proposed topologies. To shape the input line currents, a fast and robust controller based on a sliding mode approach is proposed. This active non-linear control strategy, applied to these converters allows high quality input currents. A Proportional Integral (PI) controller is adopted to regulate the output voltage of the converters. This external voltage controller modulates the amplitude of the sinusoidal input current references. The performances of the presented rectifiers are verified with experimental results.