• 제목/요약/키워드: Potential Pole

검색결과 71건 처리시간 0.033초

배전용 전주와 접지전극의 이격거리에 따른 접촉전압 (Touch Voltage According to the Distance between Distribution Concrete Pole and Ground Rod)

  • 이복희;정현욱;이태형;백영환;이동문;정동철;이규선;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.391-394
    • /
    • 2005
  • This paper describes the touch voltages and potential distributions according to the distance between distribution concrete pole and ground rod when the current is injected to a ground rod through overhead ground wire. Touch voltage is measured in four directions. The touch voltage and ground potential distribution per 1 A are analyzed. The touch voltage was the highest at the around surface just above the ground rod.

  • PDF

Analytical Prediction and Experimental Verification of Electromagnetic Performance of a Surface-Mounted Permanent Magnet Motor having a Fractional Slot/Pole Number Combination

  • Hong, Sang-A;Choi, Jang-Young;Jang, Seok-Myeong
    • Journal of Magnetics
    • /
    • 제19권1호
    • /
    • pp.84-89
    • /
    • 2014
  • This paper presents an analytical prediction and experimental verification of the electromagnetic performance of a parallel magnetized surface-mounted permanent magnet (SPM) motor having a fractional number of slots per pole combination. On the basis of a two-dimensional (2-D) polar coordinate system and a magnetic vector potential, analytical solutions for flux density produced by the permanent magnets (PMs) and stator windings are derived. Then, analytical solutions for back-electromotive force (emf) and electromagnetic torque are derived from these field solutions. The analytical results are thoroughly validated with 2-D nonlinear finite element (FE) analysis results. Finally, the experimental back-emf and electromagnetic torque measurements are presented to test the validity of the analysis.

물체의 고유 Pole을 이용한 지하 속의 빈 공간 식별 방안 (A methodology for Identification of an Air Cavity Underground Using its Natural Poles)

  • 이우진
    • 한국산학기술학회논문지
    • /
    • 제22권6호
    • /
    • pp.566-572
    • /
    • 2021
  • 본 논문에서는 도시환경과 모래가 많은 토양 아래에 구 형태의 빈 공간이 있을 경우를 가정하고, 해당 목표물의 고유 pole과 고유 공진주파수를 활용하여 목표물을 식별 및 위치를 추정하는 방안을 제시하였으며 가능성을 분석하였다. EM(Electromagnetic) 시뮬레이터를 활용하여 다양한 형태와 크기를 가진 완전도체(PEC: Perfect Electric Conductor)들을 모델링하였고, 이를 통해 획득한 EM 산란응답에 Cauchy 방법을 적용하여 물체의 고유 특성에 해당하는 고유 pole을 축적하여 pole 라이브러리를 생성하였다. 생성된 pole 라이브러리는 목표물에서 추출한 고유 pole과의 비교를 통해 목표물을 식별할 수 있는 가능성을 제공해 준다. 도시환경과 모래가 많은 토양 아래에 구 형태의 빈 공간이 있음을 가정하고 EM 시뮬레이션 모델링을 통해 얻은 전자파 산란 데이터로부터 관심 목표물의 응답을 추출하였으며, 시간영역에서 임펄스 응답의 시간 지연을 이용하여 목표물의 위치를 추정할 수 있었다. 또한 MP(Matrix Pencil) 방법을 적용하여 목표물의 고유 pole을 추출하였다. 최종적으로 계산된 고유 pole과 고유 공진주파수를 pole 라이브러리와 비교하여 탐지된 목표물을 구 형태의 빈 공간(직경 0.2m)으로 추정할 수 있었으며, 계산된 목표물의 위치(깊이)는 약 84 ~ 93%의 정확도를 보였다.

접지봉 설치에 따른 전주 주변의 전위분포 (Potential Distribution near Concrete Pole According to the position of Ground Rod)

  • 이복희;정현욱;최종혁;조성철;백영환;이규선;안창환
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.342-346
    • /
    • 2006
  • This paper describes ground surface potential rises and touch voltage. The more soil resistivity of upper layer is lower, the more ground surface potential rise is increased. Ground surface potential rise is increased as the buried depth of ground rod in lowered. Ground surface potential rises were measured in the test site and compared with results by CDEGS program. Touch voltages according to the separation distance of ground rod were measured in four directions. Touch voltages were remarkably changed by separation distance and contact position.

  • PDF

Improved Method for Calculating Magnetic Field of Surface-Mounted Permanent Magnet Machines Accounting for Slots and Eccentric Magnet Pole

  • Zhou, Yu;Li, Huaishu;Wang, Wei;Cao, Qing;Zhou, Shi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1025-1034
    • /
    • 2015
  • This paper presented an improved analytical method for calculating the open-circuit magnetic field in the surface-mounted permanent magnet machines accounting for slots and eccentric magnet pole. Magnetic field produced by radial and parallel permanent magnet is equivalent to that produced by surface current according to equivalent surface-current method of permanent magnet. The model is divided into two types of subdomains. The field solution of each subdomain is obtained by applying the interface and boundary conditions. The magnet field produced by equivalent surface current is superposed according to superposition principle of vector potential. The investigation shows harmonic contents of radial flux density can be reduced a lot by changing eccentric distance of eccentric magnet poles compared with conventional surface-mounted permanent-magnet machines with concentric magnet poles. The FE(finite element) results confirm the validity of the analytical results with the proposed model.

DEGENERATE VOLTERRA EQUATIONS IN BANACH SPACES

  • Favini, Angelo;Tanabe, Hiroki
    • 대한수학회지
    • /
    • 제37권6호
    • /
    • pp.915-927
    • /
    • 2000
  • This paper is concerned with degenerate Volterra equations Mu(t) + ∫(sub)0(sup)t k(t-s) Lu(s)ds = f(t) in Banach spaces both in the hyperbolic case, and the parabolic one. The key assumption is played by the representation of the underlying space X as a direct sum X = N(T) + R(T), where T is the bounded linear operator T = ML(sup)-1. Hyperbolicity means that the part T of T in R(T) is an abstract potential operator, i.e., -T(sup)-1 generates a C(sub)0-semigroup, and parabolicity means that -T(sup)-1 generates an analytic semigroup. A maximal regularity result is obtained for parabolic equations. We will also investigate the cases where the kernel k($.$) is degenerated or singular at t=0 using the results of Pruss[8] on analytic resolvents. Finally, we consider the case where $\lambda$ is a pole for ($\lambda$L + M)(sup)-1.

  • PDF

다극회전자를 갖는 영구자석기기의 코깅토크에 대한 해석적 예측 (Analytical Prediction for the Cogging Torque of the Permanent Magnet Machines With Multi-Pole Rotor)

  • 장석명;최장영;고경진;박지훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.56-58
    • /
    • 2007
  • This paper deals with analytical prediction for the cogging torque of permanent magnet machines with multi-pole rotor First. open-circuit field solutions are derived using a magnetic vector potential and a two-dimensional (2-d) polar coordinate systems. On the basis of derived open-circuit field solutions and 2-d permeance functions. we also derive the analytical solutions for the open-circuit field considering stator slotting effects and cogging torque. All analytical results are shown in goof agreement with those obtained from finite element (FE) analyses.

  • PDF

Influence of time delay and saturation capacity to the response of controlled structures under earthquake excitations

  • Pnevmatikos, Nikos G.;Gantes, Charis J.
    • Smart Structures and Systems
    • /
    • 제8권5호
    • /
    • pp.449-470
    • /
    • 2011
  • During the last thirty years many structural control concepts have been proposed for the reduction of the structural response caused by earthquake excitations. Their research and implementation in practice have shown that seismic control of structures has a lot of potential but also many limitations. In this paper the importance of two practical issues, time delay and saturation effect, on the performance of controlled structures, is discussed. Their influence, both separately and in interaction, on the response of structures controlled by a modified pole placement algorithm is investigated. Characteristic buildings controlled by this algorithm and subjected to dynamic loads, such as harmonic signals and actual seismic events, are analyzed for a range of levels of time delay and saturation capacity of the control devices. The response reduction surfaces for the combined influence of time delay and force saturation of the controlled buildings are obtained. Conclusions regarding the choice of the control system and the desired properties of the control devices are drawn.

주상용 몰드변압기의 온도분포와 열응력 해석 (The Temperature Distribution and Thermal Stress Analysis of Mold transformer)

  • 조한구;이운용;한세원
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.387-390
    • /
    • 2000
  • The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. Therefore design time and design cost are decreased by numerical analysis. In this paper, the temperature distribution and thermal stress analysis of 50kVA pole cast resin transformer for power distribution are investigated by FEM program. The temperature change according to load rates of transformer also have been investigated. We have carried out temperature rise test and test results are compared with simulation data.

  • PDF

중성자 흡수소재용 냉간 압연된 Gd-저합금 이상 스테인레스 강의 부식 및 마모성 (Corrosion and Wear Properties of Cold Rolled 0.087% Gd-Lean Duplex Strainless Steels for Neutron Absorbing Material)

  • 백열;최용
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2015년도 춘계학술대회 논문집
    • /
    • pp.123-123
    • /
    • 2015
  • 0.087 wt.% Gd-lean duplex stainless steels were inert arc-melted and cast in a mold. The micro-hardnesses of the rolling, transverse, short transverse directions were 258.5, 292.3, 314.7 HV, respectively. The 33% cold rolled specimen had the crystallographic texture that mainly (100) pole was concentrated to normal direction and (110) pole was concentrated in the center of normal and rolling directions. The corrosion potential and corrosion rate in artificial sea water were in the range of $105.6-221.6mV_{SHE}$, $0.59-1.06mA/cm^2$, respectively. The friction coefficient and wear loss of the 0.087 wt.% Gd-lean duplex stainless steels in artificial sea water were about 67% and 65% lower than in air, whereas, the wear efficiency was 22% higher. The corrosion and wear behaviors of the 0.087 wt.% Gd-lean duplex stainless steels significantly depended on the gadolinium phases.

  • PDF