A comparative study of bite force associated with remaining bone level in anterior and premolar teeth at periodontal maintenance phase (유지관리기 치주환자의 전치 및 소구치에서 잔존 치조골량에 따른 교합력의 비교 연구)

  • Song, Gyu-Won;Yim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.643-653
    • /
    • 2002
  • Periodontal supporting tissue goes through destruction by chronic inflammatory periodontal disease as two aspect. One is qualitive aspect such as alteration of periodontium, the other is quantitative aspect such as alveolar bone loss. According to many authors, PDL is responsible for biting force, and there are two mean. for measuring PDL's function - mobility test and biting force test. This study was conducted to compare the biting force with remaining bone level, that is, quantitative aspect of periodontium, in anterior and premolar teeth at periodontal maintenance phase. 17 patients on periodontal maintenance phase during 6 months at minimum were selected for this study. For the same condition, 4 anterior, canine, premolar teeth were tested by MPM-3000 bite-force register at the same time(a.m.l0-12), the same position, the same posture, by the same examiner. Patients of TMI), ill-fitting pros thesis, general disease, malocclusion and the teeth of TFO, absence of opposing teeth, malposition were excluded. Remaining bone level was measured on the panorama X-ray film through 5 level from 1mm below CEJ to root apex. Teeth were examined twice, and bigger one was selected. If the values showed large difference. examinatin was re-done and the mean was selected. The results were as follows ; 1. In the 4 anterior group, as the remaining bone is decreased, the average of maximal biting force is decreased. Especially, at 3/5 bone level, maximal biting force is decreased significantly(p<0.01). 2. In the canine group, as the remaining bone is decreased, the average of maximal biting force is decreased. Especially, at 2/5 bone level, maximal biting force is decreased significantly(p<0.01). 3. In the premolar group, as the remaining bone is decreased, the average of maximal biting force is decreased. Especially, at 3/5 bone level, maximal biting force is decreased significantly(p<0.05). From the results of this study, clinicians could utilize these efficiently when they have to determine the proper restorative materials, time for tooth extraction, treatment plan, prognosis.

Performance Evaluation of Balance Ability Equipment Using VR (VR을 이용한 균형능력 측정장비의 성능평가)

  • Yoon, Sangcheol;An, Howon;Ahn, Taekwon;Choi, Haesung;Lee, Byoungkwon;Seo, Dongkwon;Lee, Kyuhwan;Jung, Sangwoo;Yi, Jaehoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.3
    • /
    • pp.33-41
    • /
    • 2020
  • Purpose : Conventional Balance Measurement can only measure the center of gravity and the shaking movement of the body. As a result, it has the disadvantages of not responding to visual changes and blocking functions of variables. This study was carried out to evaluate the performance of new equipment that measures the balance of the body using changes in body segment and pressure using the acceleration sensor to compensate for the disadvantages of the existing equipment. Methods : To this end, balance ability was measured in 43 healthy male/female adults without orthopedic injuries and nervous system damage in the last 6 months. in a situation where the visual information was restricted by Virtual Reality (VR) gear, all subjects measured and evaluated the balance ability utilizing the new equipment. Balance measurement (Prime Medilab, Korea) and Wii fit (Nintendo, Japan) were used to measure the balance ability of the subjects, and the balance ability test was performed in 4 postures using each device for data acquisition. The test duration for each posture was 30 seconds. For data acquisition, the average value of three experiments measured using each equipment was analyzed, and the statistical test was performed using the independent sample and the corresponding sample t-test, and the significance level was set to α=.05. Results : As a result of measuring the balance ability using individual equipment, blocking visual information using VR gear, the average speed, maximum speed, and moving area of the COP increased equally. It was found that the obtained absolute size of the result in Wii was somewhat larger than that of BM. Conclusion : It is considered that in the future research, it is necessary to measure changes in the body's center of gravity through image analysis, etc., to make clear comparison and evaluation of the usability.

Reliability and Validity of the Korean Version of the Fear of Daily Activities Questionnaire for Patients with Low Back Pain (허리통증 환자의 한국판 일상동작 공포설문지의 신뢰도와 타당도)

  • Cha, Yong-Jun;Kim, Kyoung
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.5
    • /
    • pp.224-232
    • /
    • 2011
  • The purpose of this study was to test the reliability and validity of the Korean version of the fear of daily activities questionnaire (FDAQ) for low back pain patients. Seventy-three subjects with low back pain were participated in this study. The subjects completed ten standardized self-administered questionnaires that measure fear of specific daily activities. The reliability of the acquired data was determined by the intra-class correlation coefficient (ICC) and the Cronbach's ${\alpha}$ for internal consistency. Constructive validity was analyzed by factor analysis, and concurrent validity was acquired from comparison FDAQ scores to the visual analogue scale (VAS) and Oswestry disability index (ODI) scores. The test-retest reliability of the Korean version of the FDAQ showed good ICC (2,1)= 0.96 (95%CI 0.94.0.98) and Cronbach's alpha value was 0.93. Factor analysis suggested two factors solution consisting of spinal loading and spinal movement/posture, it explained 76.1% of the total variance. The concurrent validity was moderately related with pain and disability. Therefore, the Korean version of the FDAQ is a useful method for measuring the fear of daily activities of patients with low back pain.

A Study on the Wireless Ship Motion Measurement System Using AHRS (AHRS를 이용한 무선 선체 운동 측정 시스템에 관한 연구)

  • Kim, Dae-Hae;Lee, Sang-Min;Kong, Gil-Young
    • Journal of Navigation and Port Research
    • /
    • v.37 no.6
    • /
    • pp.575-580
    • /
    • 2013
  • The IMU(Inertial Measurement Unit) which is the expensive equipment has been used as a special limited area, usually in measurement of posture of applying to the areas of ship, submarine, aircraft and military equipment application. However, in the current situation, MEMS AHRS technology can replace the high-priced IMU in MEMS AHRS selected application field. In this paper, wireless hull motion measurement system was suggested for measuring key elements of ship's movement such as rolling, pitching and yawing using gyro, acceleration and magnetic sensors of AHRS. In order to reduce the error such as instantaneous acceleration, effects and vibration of geomagnetic, we have adopted the sensors equipped with Kalman filtering. The Wireless hull motion measurement system using AHRS sensors was tested in actual ship and it could easily be applied in limited installation circumstances of the ship. In the future, this system can be useful in the navigation safety and marine accident analysis by using with ship equipment such as INS or VDR in the maritime.

The Effect of Resistance Exercise with Vibration Stimulation on Balance and Gait of Experienced Back Pain Adults (진동자극 저항운동이 허리통증 경험자의 균형과 보행에 미치는 영향)

  • Ko, Min-Gyun
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.6
    • /
    • pp.221-230
    • /
    • 2020
  • The purpose of this study was to investigate the effect of resistance exercise with vibration stimulation methods on static balance and gait parameters in experienced back pain adults. This study was Three group pretest-posttest design. A total of 30 experienced back pain adults voluntarily participated in the study. Subjects were randomly assigned to the resistance exercise with 8 Hz vibration stimulation(n=10), resistance exercise with 30 Hz vibration stimulation(n=10), and lumbar stabilization exercise groups(n=10). The static balance and the gait parameters, as such stance phase, swing phase, stride length and cadence, were measured using balance measuring equipment and gait analysis treadmill at before and after 6 week. Intervention of each group were performed, three times a week for 6 weeks, and 30 minutes a day. The effect of intervention on static balance, stance phase, swing phase, stride length and cadence were significantly differences after 6 weeks in each group(p<.05). In the comparison of the effects between the groups, static balance and stance phase were significantly difference after 6 weeks(p<.05), but in the swing phase, stride length and cadence, there were no significant differences. As a result, it is considered that resistance exercise with vibration stimulation improved leg muscle strength by a mechanism causing muscle contraction, and the strengthened leg muscle enhanced had a positive effect on balance ability. And improved balance ability was considered a more positive effect on walking ability by allowing the body to stably control posture while moving.

Implementation of Acceleration Sensor-based Human activity and Fall Classification Algorithm (가속도 센서기반의 인체활동 및 낙상 분류를 위한 알고리즘 구현)

  • Hyun Park;Jun-Mo Park;Yeon-Chul, Ha
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.2
    • /
    • pp.76-83
    • /
    • 2022
  • With the recent development of IT technology, research and interest in various biosignal measuring devices is increasing. As an aging society is in full swing, research on the elderly population using IT-related technologies is continuously developing. This study is about the development of life pattern detection and fall detection algorithm, which is one of the medical service areas for the elderly, who are rapidly developing as they enter a super-aged society. This study consisted of a system using a 3-axis accelerometer and an electrocardiogram sensor, collected data, and then analyzed the data. It was confirmed that behavioral patterns could be classified from the actual research results. In order to evaluate the usefulness of the human activity monitoring system implemented in this study, experiments were performed under various conditions, such as changes in posture and walking speed, and signal magnitude range and signal vector magnitude parameters reflecting the acceleration of gravity of the human body and the degree of human activity. was extracted. And the possibility of discrimination according to the condition of the subject was examined by these parameter values.

Evaluation of the Usefulness of Assist Device for Rosenberg View Test (Rosenberg View 검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Kim, In Soo;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.129-138
    • /
    • 2020
  • Due to the nature of the Rosenberg Method, the patient needs to maintain posture for a certain period of time, and the joint space is observed in various forms depending on the angle of knee flexion, which causes difficulties in examination. In order to solve these problems, Image quality was evaluated in order to evaluate the usefulness of the assistive device by making the assistive device itself. SNR and CNR analysis about the presence or absence of an assistive device using the extremity phantom and the angle of the assistive device itself were not statistically significant(p < 0.05). As a result of measuring the distance between the right and left edges of the medial condyle based on the presence or absence of an assist device, and the absence of assist device (96.00±40.6 mm) and presence of an assist device (134.86±17.68 mm) were statistically significant (p <0.05). To find the aLDFA relationship about the femur and tibia, we measured the right and left aLDFA based on the presence or absence of assist device. As a result, the absence of the right-side aLDFA assist device (74.63°±4.87) and the presence of assist device (79.64°±3.65) were statistically significant (p <0.05). The absence of the left-side aLDFA assist device (76.39°±4.62) and the presence of assist device (79.64°±3.65) were statistically significant (p < 0.05). but, As a result of measuring the distance of the overlapping parts of the right and left proximal tibiofibular joint and the lateral condyle, There were no statistically significant differences between the right and left sides. In conclusion, we confirmed that we can obtain Diagnostically valuable images with a constant knee-to-knee spacing using an assist device we self-created. In addition, we could learn through aLDFA relationship between femur and tibial that the smaller the angle, the more medial condyle overlaps with JSW, We also confirmed the significance by deriving similar values on the normal range values of aLDFA using assist devices. However, it is considered necessary to pay attention to internal and external rotations in order to obtain good quality images by evaluating the distance of overlapping parts between proximal tibiofibular joint and lateral condyle.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

A Study of the Health Promoting Life Style in Rural Area (일부 농촌주민의 건강증진 생활양식 수행정도)

  • Jung, Young-Ok;Kim, Sang-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.20 no.2
    • /
    • pp.133-148
    • /
    • 1995
  • This study was to identify the factors affecting the performance in health promoting lifestyle and measuring health promoting lifestyle. The subjects for this study were all adult in rural area, Kakbuk Nyun, Chung-do Gun, Kyungpook, Korea. The data were collected during the period from April 1 to April 30, 1995. The instruments used for this study were the health promoting lifestyle by Park(1995). The results of this study are as follows. Health condition felt by the subjects was worse in female group and was getting worse according as the age increase. According to health promoting life style implementation questionnaire, more than half of the subjects responded "never" in deep breathing 3 times a day item and non-smoking item; more than half of the subjects responded "yes" in 3 meal a day item, home-cooked meals item, never to omit breakfast item and frequent wearing of cotton underwear item. Health promoting life style implementation by health condition is higher in healthy group and frequency of consulting a specialist is higher in unhealthy group. Health promoting life style implementation by sex is higher in male group. Frequency, of consulting a specialist and non-excessive drinking are higher in female group. Health promoting life style implementation by age showed that the implementation of never omitting breakfast, keeping early hours and proper sleeping is higher in old age group ; that of enjoying hobby, pastime, cleaning as well as reading health books is higher in young age group. Health promoting life style implementation by religion showed that the implementation of deep breathing 3 times more a day, regular checking of blood pressure, never having non-healthful food and keeping right posture in sitting and standing is higher in religion group. Health promoting life style implementation by education is higher in highly-educated group ; the implementation of keeping early hours is higher in low-educated group. Health promoting life style implementation by marriage state showed that the implementation of deep breathing 3 times more a day, twenty minutes of brisk physical movement three or four times a week, enjoying his or her own time, relaxation to relieve from tension and pressure and equalized movement of each part of body is higher in unmarred group ; that of having elaborately cooked food, never omitting three meals a day and keeping early hours is higher in married group. Health promoting life style implementation by the number of family members showed that more-member-group has more plans and objectives for their future. Health promoting life style implementation by family type showed that the implementation of reading health books and articles, living with positive way of thinking and enjoying favorite hobby in pastime is higher in nuclear families ; that of having three meals a day never omitting breakfast is higher in large families.

  • PDF

USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN (전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가)

  • Park, Do-Geun;Choe, Byeong-Gi;Kim, Jin-Man;Lee, Dong-Hun;Song, Gi-Won;Park, Yeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.127-135
    • /
    • 2014
  • Purpose : By taking advantage of each imaging modality, the use of fused CT/MRI image has increased in prostate cancer radiation therapy. However, fusion uncertainty may cause partial target miss or normal organ overdose. In order to complement such limitation, our hospital acquired MRI image (Planning MRI) by setting up patients with the same fixing tool and posture as CT simulation. This study aims to evaluate the usefulness of the Planning MRI through comparing and analyzing the diagnostic MRI image and Planning MRI image. Materials and Methods : This study targeted 10 patients who had been diagnosed with prostate cancer and prescribed nonhormone and definitive RT 70 Gy/28 fx from August 2011 to July 2013. Each patient had both CT and MRI simulations. The MRI images were acquired within one half hour after the CT simulation. The acquired CT/MRI images were fused primarily based on bony structure matching. This study measured the volume of prostate in the images of Planning MRI and diagnostic MRI. The diameters at the craniocaudal, anteroposterior and left-to-right directions from the center of prostate were measured in order to compare changes in the shape of prostate. Results : As a result of comparing the volume of prostate in the images of Planning MRI and diagnostic MRI, they were found to be $25.01cm^3$(range $15.84-34.75cm^3$) and $25.05cm^3$(range $15.28-35.88cm^3$) on average respectively. The diagnostic MRI had an increase of 0.12 % as compared with the Planning MRI. On the planning MRI, there was an increase in the volume by $7.46cm^3$(29 %) at the transition zone directions, and there was a decrease in the volume by $8.52cm^3$(34 %) in the peripheral zone direction. As a result of measuring the diameters at the craniocaudal, anteroposterior and left-to-right directions in the prostate, the Planning MRI was found to have on average 3.82cm, 2.38cm and 4.59cm respectively and the diagnostic MRI was found to have on average 3.37cm, 2.76cm and 4.51cm respectively. All three prostate diameters changed and the change was significant in the Planning MRI. On average, the anteroposterior prostate diameter decrease by 0.38cm(13 %). The mean right-to-left and craniocaudal diameter increased by 0.08cm(1.6 %) and 0.45cm(13 %), respectively. Conclusion : Based on the results of this study, it was found that the total volumes of prostate in the Planning MRI and the diagnostic MRI were not significantly different. However, there was a change in the shape and partial volume of prostate due to the insertion of prostate balloon tube to the rectum. Thus, if the Planning MRI images were used when conducting the fusion of CT/MRI images, it would be possible to include the target in the CTV without a loss as much as the increased volume in the transition zone. Also, it would be possible to reduce the radiation dose delivered to the rectum through separating more clearly the reduction of peripheral zone volume. Therefore, the author of this study believes that acquisition of Planning MRI image should be made to ensure target delineation and localization accuracy.